Optimization and working performance analysis of liquid cooling plates in refrigerant direct cooling power battery systems

被引:4
|
作者
Tang, Aikun [1 ]
Yang, Jiaze [1 ]
Yang, Peng [1 ]
Zhang, Han [1 ]
Cai, Tao [1 ]
机构
[1] Jiangsu Univ, Sch Energy & Power Engn, Zhenjiang 212013, Peoples R China
关键词
Lithium-ion battery; Battery thermal management; Refrigerant direct cooling; Cooling plate optimization; Cooling characteristics; THERMAL MANAGEMENT-SYSTEM; LITHIUM-ION BATTERIES; ELECTRIC VEHICLES; SIMULATION; DESIGN; MODULE;
D O I
10.1016/j.ijheatmasstransfer.2024.125899
中图分类号
O414.1 [热力学];
学科分类号
摘要
Refrigerant direct cooling is currently being considered as an efficient thermal management technology in power battery systems. In this paper, four types of liquid cooling plates for power battery modules are designed and the computational model is constructed. With the model being validated, it is applied to analyze the effects of the cooling plate structure and cooling channel on the cooling and heat dissipation performances. The results reveal that for the conventional cooling method, i.e., when the cooling plate is placed on the bottom of the battery pack, a significant temperature gradient in the vertical direction is observed. On the contrary, adopting a serpentine cooling plate structure in the main wall or parallel cooling channels in the narrow side wall could significantly reduce the temperature difference of the battery pack, which can keep the temperature difference within 5 degrees C even under extreme conditions. Further, a detailed analysis of the heat dissipation performance based on the optimal cooling plate structure is performed to determine the safe operating range of the battery pack. It is shown that as the humidity is less than 0.73 and the evaporation temperature is below 15.43 degrees C, the battery pack can operate safely. However, beyond this condition range the heat dissipation characteristics of the battery pack cannot satisfy the operating requirements. This work sheds light upon the potential of refrigerant direct cooling strategy in power battery thermal management systems by properly arranging the cooling plate.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] An experimental investigation of refrigerant emergency spray on cooling and oxygen suppression for overheating power battery
    Gao, Qing
    Liu, Yubin
    Wang, Guohua
    Deng, Fan
    Zhu, Jichen
    JOURNAL OF POWER SOURCES, 2019, 415 : 33 - 43
  • [32] POWER INVERTERS IN FORM OF MICROMODULE WITH DIRECT LIQUID COOLING
    Krainyukov, Alexander
    Saltanovs, Rodions
    17TH INTERNATIONAL SCIENTIFIC CONFERENCE: ENGINEERING FOR RURAL DEVELOPMENT, 2018, : 1587 - 1592
  • [33] Optimization of the Cooling Performance of Symmetric Battery Thermal Management Systems at High Discharge Rates
    Feng, Zixiao
    Zhao, Jiapei
    Guo, Changwei
    Panchal, Satyam
    Xu, Yuan
    Yuan, Jinliang
    Fraser, Roydon
    Fowler, Michael
    ENERGY & FUELS, 2023, 37 (11) : 7990 - 8004
  • [34] Battery thermal management systems for electric vehicles: an overview of cooling techniques and performance optimization
    Koundal, Sumit
    Sharma, Sohan Lal
    Debbarma, Ajoy
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2025,
  • [35] Research on fast-charging battery thermal management system based on refrigerant direct cooling
    Dai, Naichang
    Long, Jiangqi
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [36] Research on fast-charging battery thermal management system based on refrigerant direct cooling
    Naichang Dai
    Jiangqi Long
    Scientific Reports, 13
  • [37] Thermal performance analysis of battery thermal management system utilizing bionic liquid cooling plates with differentiated velocity distribution strategy
    Xie, Jiekai
    Zhang, Guoqing
    Yang, Xiaoqing
    APPLIED THERMAL ENGINEERING, 2024, 249
  • [38] Unsteady Computational Flow Analysis and Experimental Study on the Performance Prediction of Battery Module Cooling Plates
    Park, Sang Hwan
    Chang, Kyoungsik
    Cho, Hong Young
    Jeong, Hui Seok
    Sohn, Sung Man
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2021, 45 (07) : 389 - 396
  • [39] Numerical Analysis of Cooling Plates with Different Structures for Electric Vehicle Battery Thermal Management Systems
    Li, Ming
    Wang, Jianchao
    Guo, Qin
    Li, Yue
    Xue, Qingfeng
    Qin, Guihe
    JOURNAL OF ENERGY ENGINEERING, 2020, 146 (04)
  • [40] Effect analysis on integration efficiency and safety performance of a battery thermal management system based on direct contact liquid cooling
    Wu, Shangquan
    Lao, Li
    Wu, Lin
    Liu, Lei
    Lin, Chunjing
    Zhang, Qingchuan
    APPLIED THERMAL ENGINEERING, 2022, 201