Analytical Determination of Ochratoxin A in Brewed and Green Coffee Beans by High-Performance Liquid Chromatography - Fluorescent Detector Method

被引:0
|
作者
Kelecha, Abiyot Geletu [1 ]
Desa, Bilisa Kebeda [2 ]
Teshome, Kokob Wondimu [1 ]
机构
[1] Mattu Univ, Coll Nat & Computat Sci, Dept Chem, Mattu, Ethiopia
[2] Alge Sachi Secondary Sch, Dept Chem, Ilu Aba Bora, Alge Sachi, Ethiopia
来源
IRANIAN JOURNAL OF CHEMISTRY & CHEMICAL ENGINEERING-INTERNATIONAL ENGLISH EDITION | 2024年 / 43卷 / 01期
关键词
Mycotoxins; Ochratoxin A; Coffee; HPLC; Immunoaffinity column; MYCOTOXINS; FOOD; UPDATE; FUNGI;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Coffee contamination by Ochratoxin A (OTA) is becoming the main global emerging threat to its quality. The main objective of this study was to determine the levels of Ochratoxin A in coffee beans and brewed coffee samples. Twenty samples of coffee beans and brewed were each randomly collected from coffee stores and street coffee vendors, respectively. The levels of OTA in the coffee samples were determined using High-Performance Liquid Chromatography (HPLC) with a Fluorescence Detector (FD). The calibration curve for the analyte was linear in the concentration range of 1 mu g/L mu g/L- 15 mu g/L mu g/L (R2 2 = 0.997) and 1 mu g/kg mu g/kg- 15 mu g/kg for green coffee beans (R-2 = 0.998). The mean concentration of OTA in brewed and coffee beans composite samples was found to be 1.92 mu g/L +/- 0.07 mu g/L (n=10) and 1.52 mu g/kg +/- 0.28 mu g/kg (n=10), respectively. The Limit of Detection (LOD) and Limit of Quantification (LOQ) of the method calculated from the calibration curves were 0.76 mu g/kg, 0.69 mu g/L and 2.31 mu g/kg, 2.07 mu g/kg for green coffee bean and brewed samples, respectively. The precision of the method expressed in percent Relative Standard Deviations (RSD) of the recoveries was less than 20 % and the mean recovery was 76.28 % - 106.57%. Even though the concentrations of OTA in studied samples didn't exceed the maximum residue limit set by international organizations, a positive result signals coffee pollution by these toxic substances and careful monitoring is essential to improve the quality of coffee and halt its health and economic effects.
引用
收藏
页码:294 / 301
页数:8
相关论文
共 50 条
  • [21] Determination of ochratoxin A in Portuguese rice samples by high performance liquid chromatography with fluorescence detection
    A. Pena
    F. Cerejo
    C. Lino
    I. Silveira
    Analytical and Bioanalytical Chemistry, 2005, 382 : 1288 - 1293
  • [22] Determination of ochratoxin A in wine by means of immunoaffinity column clean-up and high-performance liquid chromatography
    Visconti, A
    Pascale, M
    Centonze, G
    JOURNAL OF CHROMATOGRAPHY A, 1999, 864 (01) : 89 - 101
  • [23] Determination of Ochratoxin A in Human Blood Serum by High-Performance Liquid Chromatography: Method Validation and Comparison of Extraction Procedures
    Ghali, R.
    Hmaissia-Khlifa, K.
    Ghorbel, H.
    Mezigh, Ch.
    Maaroufi, K.
    Hedili, A.
    ANALYTICAL LETTERS, 2008, 41 (13) : 2452 - 2464
  • [24] Determination of ochratoxin A in pig tissues using enzymatic digestion coupled with high-performance liquid chromatography with a fluorescence detector
    Giacomo, Luci
    Michele, Vanni
    Guido, Ferruzzi
    Danilo, Mani
    Luigi, Intorre
    Valentina, Meucci
    METHODSX, 2016, 3 : 171 - 177
  • [25] Determination of ochratoxin A in pig tissues by liquid–liquid extraction and clean-up and high-performance liquid chromatography
    L. Monaci
    G. Tantillo
    F. Palmisano
    Analytical and Bioanalytical Chemistry, 2004, 378 : 1777 - 1782
  • [26] Determination of Ochratoxin A in Licorice and Licorice Extracts by High-Performance Liquid Chromatography Coupled with Fluorescence Detection: Collaborative Study
    Lerda, Donata
    Ambrosio, Massimo
    Kunsagi, Zoltan
    Stroka, Joerg
    JOURNAL OF AOAC INTERNATIONAL, 2013, 96 (02) : 331 - 340
  • [27] Use of high-performance liquid chromatography to assess airborne mycotoxins -: Aflatoxins and ochratoxin A
    Tarín, A
    Rosell, MG
    Guardino, X
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1047 (02) : 235 - 240
  • [28] Determination of trace levels of hydroxyhydroquinone in coffee by high-performance liquid chromatography
    Ozaki, Makoto
    Naoe, Ayano
    Tsujimura, Hisashi
    Kusaura, Tatsuya
    Hozumi, Kouki
    Kondou, Naoki
    Masukawa, Yoshinori
    BUNSEKI KAGAKU, 2008, 57 (01) : 23 - 30
  • [29] Improved fluorescent determination method of cellular sphingoid bases in high-performance liquid chromatography
    Yoon, HT
    Yoo, HS
    Shin, BK
    Lee, WJ
    Kim, HM
    Hong, SP
    Moon, DC
    Lee, YM
    ARCHIVES OF PHARMACAL RESEARCH, 1999, 22 (03) : 294 - 299
  • [30] Improved fluorescent determination method of cellular sphingoid bases in high-performance liquid chromatography
    Hong -Tak Yoon
    Hwan -Soo Yoo
    Bum -Kyu Shin
    Woo -Jin Lee
    Hwan -Mook Kim
    Seon -Pyo Hong
    Dong -Cheul Moon
    Yong -Moon Lee
    Archives of Pharmacal Research, 1999, 22 : 294 - 299