2D and 3D microstructural analysis of the iliotibial tract

被引:1
|
作者
Manon, Julie [1 ,2 ,3 ]
Gallant, Laurie [4 ]
Gerard, Paul [4 ]
Fieve, Lies [4 ]
Schneidewind, Pierre [4 ,5 ]
Pyka, Grzegorz [5 ,6 ]
Kerckhofs, Greet [5 ,6 ]
Lengele, Benoit [4 ,7 ]
Cornu, Olivier [1 ,2 ,3 ]
Behets, Catherine [4 ]
机构
[1] Univ Catholique Louvain UCLouvain, Inst Rech Expt & Clin IREC, Neuromusculoskeletal Lab NMSK, Brussels, Belgium
[2] Clin Univ St Luc, Dept Orthopaed & Trauma Surg, Brussels, Belgium
[3] Clin Univ St Luc, Dept Cell & Tissue Therapy, Brussels, Belgium
[4] UCLouvain IREC, Morphol Lab MORF, Brussels, Belgium
[5] UCLouvain IREC, ContrasTTeam, Brussels, Belgium
[6] UCLouvain, Inst Mech Mat & Civil Engn IMMC, Mechatron Elect Energy & Dynam Syst MEED, Louvain La Neuve, Belgium
[7] Clin Univ St Luc, Dept Plast & Reconstruct Surg, Brussels, Belgium
关键词
2D & 3D histology; fascia lata; fibre orientation; iliotibial band; iliotibial tract; spatial tissue organisation; BAND THICKNESS; FASCIA; ANATOMY;
D O I
10.1111/joa.14125
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
The fascial system has gained recognition for its integral role in connecting skin, superficial and deep fasciae, and underlying muscles. However, consensus on its microstructure depending on its topography remains elusive as well as its implications in clinical practices, such as reconstructive surgery and physiotherapy techniques. This study focuses on the iliotibial tract (ITT) implicated in the iliotibial band syndrome. The goal is to describe microstructural characteristics using classical 2D histology and cryogenic contrast-enhanced microcomputed tomography (cryo-CECT) such as the total thickness, number of layers, layer thickness, fibre orientation and tortuosity, according to the specific topography. The total thickness of the ITT varied across topographic regions, with the superior part being on average thicker but non-significantly different from the other regions. The inferior part showed heterogeneity, with the anterior region (AI) being the thinnest and the posterior one (PI) the thickest. The ITT exhibited 1-3 layers, with no significant differences among regions. Most commonly, it consisted of two layers, except for the antero-superior (AS) and antero-middle (AM) regions, which sometimes had only one layer. The posterior regions frequently had 2 or 3 layers, with the PI region having the highest mean (2.7 layers). The intermediate layer was the thickest one, varying from the AI region (0.368 mm +/- 0.114) to the PI region (0.640 mm +/- 0.305). The superficial layer showed regional variability, with the AS region being the thinnest. The deep layer appeared thinner than the superficial one. Fibre orientation analysis indicated that the intermediate layer mainly consisted of oblique longitudinal fibres, orientated downward and forward, while the superficial and deep layers had transversal or oblique transversal fibres. Cryo-CECT 3D observations confirmed these findings, revealing distinct orientations for different layers. Fibre tortuosity exhibited differences based on orientation. Transversal fibres (>65 degrees) were significantly less tortuous than longitudinal fibres (<25 degrees) and oblique intermediate fibres (25 degrees-65 degrees), aligning with 3D plot observations. This quantitative study highlights various microstructural characteristics of the ITT, offering insights into its regional variations. The analysis accuracy is increased due to the novel technology of cryo-CECT which emerges as a valuable tool for precise assessment of 3D fibre orientation and tortuosity. These findings contribute to a deeper understanding of the ITT structure, useful in clinical practices, such as reconstructive surgery and physiotherapy, and future research endeavours.
引用
收藏
页码:725 / 739
页数:15
相关论文
共 50 条
  • [31] The Overview of 2D to 3D Conversion
    Deng, Qingqing
    Zhang, Yue
    Li, Shaobin
    2013 IEEE 4TH INTERNATIONAL CONFERENCE ON ELECTRONICS INFORMATION AND EMERGENCY COMMUNICATION (ICEIEC), 2014, : 226 - 229
  • [32] 2D to 3D: Raising the stakes
    CAE, Computer-Aided Engineering, 2000, 19 (04):
  • [33] 3D Experience on a 2D Display
    Srinath, Raghunandan
    Aishwarya, P.
    Suman, B.
    Ramgopichand, V. N.
    Surabhi, N.
    2021 INTERNATIONAL CONFERENCE ON COMPUTER COMMUNICATION AND INFORMATICS (ICCCI), 2021,
  • [34] Nanoparticle superlattices in 2D and 3D
    Schatz, George
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 254
  • [35] 3D IMAGES WITH 2D FOOTPRINT
    Ferre Ferri, Enrique
    REVISTA SONDA-INVESTIGACION Y DOCENCIA EN ARTES Y LETRAS, 2020, (09): : 73 - 82
  • [36] 2D and 3D morphological and topological analysis of a clay soil
    Moreau, E
    Sardini, P
    Touchard, G
    Velde, B
    MICROSCOPY MICROANALYSIS MICROSTRUCTURES, 1996, 7 (5-6): : 499 - 504
  • [37] A quantitative analysis of wiring lengths in 2D and 3D VLSI
    Milenkovic, A
    Milutinovic, V
    MICROELECTRONICS JOURNAL, 1998, 29 (06) : 313 - 321
  • [38] An analysis of 2D and 3D multiple attenuation for a canonical example
    Ikelle, LT
    GEOPHYSICS, 2005, 70 (06) : A13 - A28
  • [39] 2D versus 3D in the kinematic analysis of the horse at the trot
    Miro, F.
    Santos, R.
    Garrido-Castro, J. L.
    Galisteo, A. M.
    Medina-Carnicer, R.
    VETERINARY RESEARCH COMMUNICATIONS, 2009, 33 (06) : 507 - 513
  • [40] 2D/3D image analysis as a tool for tissue engineering
    Martin, I
    Toso, C
    Beltrame, F
    Diaspro, A
    Fato, M
    Facchini, A
    Marcacci, M
    DePasquale, V
    Strocchi, R
    Zaffagnini, S
    MINERVA BIOTECNOLOGICA, 1997, 9 (01) : 11 - 16