Automatic virtual reconstruction of acetabular fractures using a statistical shape model

被引:0
|
作者
van Veldhuizen, W. a [1 ]
van Noortwijk, R. [1 ]
Meesters, A. m l [1 ,2 ]
Duis, K. ten [1 ]
Schuurmann, R. c l [1 ,3 ]
de Vries, J. p p m [1 ]
Wolterink, J. m [4 ]
Ijpma, F. f a [1 ]
机构
[1] Univ Med Ctr Groningen, Dept Surg, Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, 3D Lab, Groningen, Netherlands
[3] Univ Twente, Tech Med Ctr, Multimodal Med Imaging Grp, Enschede, Netherlands
[4] Univ Twente, Tech Med Ctr, Dept Appl Math, Enschede, Netherlands
关键词
Acetabular fracture; Statistical shape model; Virtual reconstruction; Contralateral mirroring; STEP; GAP;
D O I
10.1007/s00068-024-02615-7
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose Automatic virtual reconstruction of complex fractures would be helpful for pre-operative surgical planning. We developed a statistical shape model (SSM) which contains data of 200 intact 3D hemipelves. It allows for quantification of shape differences and is able to reconstruct abnormal shaped pelvises. We applied our SSM to reconstruct elementary and associate type acetabular fractures and assessed the reconstruction performance of the SSM, by comparing the reconstructed shape with the intact contralateral hemipelvis. Methods In this retrospective diagnostic imaging study, we used our SSM to virtually reconstruct fractured hemipelves of eighty-three patients with an acetabular fracture. A root mean square error (RMSE) was computed between the reconstructed shape and intact contralateral shape for the whole hemipelvis and for regions relevant for plate-fitting. These plate-fitting relevant regions were defined as: (1) Iliopectineal line length and radius; (2) ischial body line length and radius; (3) acetabular diameter, (4) quadrilateral slope and (5) weight-bearing acetabular dome. Results The median RMSE of the whole hemipelvis of the elementary type fractures was 2.2 (1.7-2.5) mm versus 3.2 (2.2-3.9) mm for the associate type fractures (p < 0.001). The median RMSE for the plate-fitting regions of elementary type fractures was 1.7 (1.4-2.1) mm versus 2.7 (2.0-4.1) mm for associate type fractures (p < 0.001). Conclusion Using a statistical shape model allows for accurate virtual reconstructions of elementary and associate type acetabular fractures within a clinically acceptable range, especially within regions important for plate-fitting. SSM-based reconstructions can serve as a valuable tool for pre-operative planning in clinical practice, when a template of the contralateral hemipelvis is unavailable.
引用
收藏
页码:2925 / 2936
页数:12
相关论文
共 50 条
  • [41] Reconstruction of the lower limb bones from digitised anatomical landmarks using statistical shape modelling
    Nolte, Daniel
    Ko, Siu-Teing
    Bull, Anthony M. J.
    Kedgley, Angela E.
    GAIT & POSTURE, 2020, 77 : 269 - 275
  • [42] Application of computerized virtual preoperative planning procedures in comminuted posterior wall acetabular fractures surgery
    Yifan Zheng
    Jianan Chen
    Siyu Yang
    Xi Ke
    Dan Xu
    Guodong Wang
    Xianhua Cai
    Ximing Liu
    Journal of Orthopaedic Surgery and Research, 17
  • [43] Automatic Generation of Statistical Pose and Shape Models for Articulated Joints
    Chen, Xin
    Graham, Jim
    Hutchinson, Charles
    Muir, Lindsay
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (02) : 372 - 383
  • [44] Computer-assisted virtual surgical procedure for acetabular fractures based on real CT data
    Hu, Yanling
    Li, Haiyan
    Qiao, Guangxi
    Liu, Haifei
    Ji, Aiyu
    Ye, Fagang
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (10): : 1121 - 1124
  • [45] Application of computerized virtual preoperative planning procedures in comminuted posterior wall acetabular fractures surgery
    Zheng, Yifan
    Chen, Jianan
    Yang, Siyu
    Ke, Xi
    Xu, Dan
    Wang, Guodong
    Cai, Xianhua
    Liu, Ximing
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [46] Building a statistical shape model of the pelvis
    Meller, S
    Kalender, WA
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 561 - 566
  • [47] Surgical Treatment of Pelvic Ring and Acetabular Fractures Using the Stoppa Approach
    Taller, S.
    Sram, J.
    Lukas, R.
    Krivohlavek, M.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2010, 77 (02) : 93 - 98
  • [48] Three-Dimensional Subject-Specific Knee Shape Reconstruction with Asynchronous Fluoroscopy Images Using Statistical Shape Modeling
    Lu, Hsuan-Yu
    Shih, Kao-Shang
    Lin, Cheng-Chung
    Lu, Tung-Wu
    Li, Song-Ying
    Kuo, Hsin-Wen
    Hsu, Horng-Chaung
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [49] Segmentation of prostate boundaries from ultrasound images using statistical shape model
    Shen, DG
    Zhan, YQ
    Davatzikos, C
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (04) : 539 - 551
  • [50] One-stop computerized virtual planning system for the surgical management of posterior wall acetabular fractures
    Jianan Chen
    Yifan Zheng
    Zhixun Fang
    Wei Zhou
    Dan Xu
    Guodong Wang
    Xianhua Cai
    Ximing Liu
    Journal of Orthopaedic Surgery and Research, 17