Transient Intraocular Pressure Fluctuations: Source, Magnitude, Frequency, and Associated Mechanical Energy

被引:54
|
作者
Turner, Daniel C. [1 ]
Edmiston, Anna M. [2 ]
Zohner, Ye Emma [3 ]
Byrne, Kevin J. [4 ]
Seigfreid, William P. [5 ]
Girkin, Christopher A. [2 ]
Morris, Jeffrey S. [6 ]
Downs, J. Crawford [2 ]
机构
[1] Univ Alabama Birmingham, Sch Optometry, Dept Vis Sci, Birmingham, AL 35294 USA
[2] Univ Alabama Birmingham, Sch Med, Dept Ophthalmol & Visual Sci, 1670 Univ Blvd,VH 390A, Birmingham, AL 35294 USA
[3] Rice Univ, Houston, TX USA
[4] Boston Univ, Sch Med, Boston, MA 02118 USA
[5] Univ Nebraska Med Ctr, Omaha, NE USA
[6] Univ Texas MD Anderson Canc Ctr, Houston, TX 77030 USA
基金
美国国家卫生研究院;
关键词
intraocular pressure; transient IOP fluctuation; glaucoma; nonhuman primate; telemetry; OCULAR PERFUSION-PRESSURE; OPTIC-NERVE DAMAGE; LAMINA-CRIBROSA; DRIVEN MECHANOTRANSDUCTION; HEALTHY-SUBJECTS; IOP TELEMETRY; RISK-FACTOR; GLAUCOMA; AGE; STRAIN;
D O I
10.1167/iovs.19-26600
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To characterize intraocular pressure (IOP) dynamics by identifying the sources of transient IOP fluctuations and quantifying the frequency, magnitude, associated cumulative IOP-related mechanical energy, and temporal distribution. METHODS. IOP was monitored at 500 Hz for periods of 16 to 451 days in nine normal eyes of six conscious, unrestrained nonhuman primates using a validated, fully implanted wireless telemetry system. IOP transducers were calibrated every two weeks via anterior chamber cannulation manometry. Analysis of time-synchronized, high-definition video was used to identify the sources of transient IOP fluctuations. RESULTS. The distribution of IOP in individual eyes is broad, and changes at multiple timescales, from second-to-second to day-to-day. Transient IOP fluctuations arise from blinks, saccades, and ocular pulse amplitude and were as high as 14 mm Hg (> 100%) above momentary baseline. Transient IOP fluctuations occur similar to 10,000 times per waking hour, with similar to 2000 to 5000 fluctuations per hour greater than 5 mm Hg (similar to 40%) above baseline. Transient IOP fluctuations account for up to 17% (mean of 12%) of the total cumulative IOP-related mechanical energy that the eye must withstand during waking hours. CONCLUSIONS. Transient IOP fluctuations occur frequently and comprise a large and significant portion of the total IOP loading in the eye and should, therefore, be considered in future studies of cell mechanotransduction, ocular biomechanics, and/or clinical outcomes where transient IOP fluctuations may be important. If IOP dynamics are similar in humans, clinical snapshot IOP measurements are insufficient to capture true IOP.
引用
收藏
页码:2572 / 2582
页数:11
相关论文
共 36 条
  • [21] Both extremes of arterial carbon dioxide pressure and the magnitude of fluctuations in arterial carbon dioxide pressure are associated with severe intraventricular hemorrhage in preterm infants - Reply
    Kaiser, Jeffrey R.
    PEDIATRICS, 2007, 119 (05) : 1039 - 1040
  • [22] Magnitude of daily energy deficit predicts frequency but not severity of menstrual disturbances associated with exercise and caloric restriction
    Williams, Nancy I.
    Leidy, Heather J.
    Hill, Brenna R.
    Lieberman, Jay L.
    Legro, Richard S.
    De Souza, Mary Jane
    AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2015, 308 (01): : E29 - E39
  • [23] Early transient intraocular pressure spike after cataract surgery in highly myopic cataract eyes and associated risk factors
    Zhu, Xiangjia
    Qi, Jiao
    He, Wenwen
    Zhang, Shaohua
    Zhang, Keke
    Lu, Qiang
    Lu, Yi
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (08) : 1137 - 1141
  • [24] Calculation of transient puffer pressure rise taking mechanical compression, nozzle ablation and arc energy into consideration
    Osawa, N
    Yoshioka, Y
    IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS: NEW WAVE OF T&D TECHNOLOGY FROM ASIA PACIFIC, 2002, : 82 - 87
  • [25] Calculation of transient puffer pressure rise takes mechanical compression, nozzle ablation, and arc energy into consideration
    Osawa, N
    Yoshioka, Y
    IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (01) : 143 - 148
  • [26] The Relationship between the 24-hour Fluctuations in Schlemm's Canal and Intraocular Pressure: An Observational Study using High-Frequency Ultrasound Biomicroscopy
    Li, Mu
    Zhao, Yin
    Yan, Xiaoqin
    Zhang, Hong
    CURRENT EYE RESEARCH, 2017, 42 (10) : 1389 - 1395
  • [27] Factors associated with fluctuations in repeated measurements of intraocular pressure using the Goldmann applanation tonometer in Japanese patients with primary open-angle glaucoma
    Yaoeda, Kiyoshi
    Fukushima, Atsushi
    Shirakashi, Motohiro
    Miki, Atsushi
    Fukuchi, Takeo
    CLINICAL OPHTHALMOLOGY, 2018, 12 : 1473 - 1478
  • [28] New Approach of Determinations of Earthquake Moment Magnitude Using Near Earthquake Source Duration and Maximum Displacement Amplitude of High Frequency Energy Radiation
    Gunawan, H.
    Puspito, N. T.
    Ibrahim, G.
    Harjadi, P. J. P.
    INTERNATIONAL CONFERENCE ON PHYSICS AND ITS APPLICATIONS (ICPAP 2011), 2012, 1454 : 138 - 141
  • [29] Factors associated with 1-year outcomes and transient intraocular pressure elevation in minimally invasive glaucoma surgery using Kahook Dual Blades
    Sakamoto, Tomoaki
    Nisiwaki, Hirokazu
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [30] Factors associated with 1-year outcomes and transient intraocular pressure elevation in minimally invasive glaucoma surgery using Kahook Dual Blades
    Tomoaki Sakamoto
    Hirokazu Nisiwaki
    Scientific Reports, 13