Percutaneous Extraction of Transvenous Permanent Pacemaker/Defibrillator Leads-A Single-Center Experience

被引:0
作者
Akcay, Murat [1 ]
Yuksel, Serkan [1 ]
机构
[1] Ondokuz Mayis Univ, Sch Med, Dept Cardiol, TR-55139 Samsun, Turkiye
来源
MEDICINA-LITHUANIA | 2024年 / 60卷 / 08期
关键词
transvenous lead extraction; indications; outcomes; single-center experience; EXPERT CONSENSUS STATEMENT; DEFIBRILLATOR LEADS; CONTROLLED ELECTRA; MORTALITY; PACEMAKER; PREDICTORS; OUTCOMES; REGISTRY; REMOVAL; SAFETY;
D O I
10.3390/medicina60081360
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives: The number of cardiac pacemakers being used has increased in recent decades, and this increase has led to a rise in device-related complications, requiring percutaneous device extraction. Our aim was to present our single-center clinical experience in percutaneous lead extractions. Materials and Methods: We analyzed an observational retrospective cohort study of 93 patients for the transvenous removal of a total of 163 endocardial leads. We evaluated the device details, indications, lead characteristics, extraction methods, complications, reimplantation procedure, follow-up data, effectiveness, and safety. Results: Patients' mean age was 68.6 +/- 11.6 years. Lead extraction indications were pocket infection in 33 (35.5%), lead dysfunction in 33 (35.5%), and system upgrade in 21 (23%) cases, and lead endocarditis in 6 (6%) cases. The duration from implantation to extraction time was a detected median of 43 (24-87) months. The most common retracted lead type was the RV defibrillator lead (62%), and the lead fixation type was active for one hundred (61%) patients. A new device was inserted in 74 (80%) patients, and the device type was most commonly a CRT-D (61%). Patients were followed up at a median of 17 (8-36) months, and 18 patients (19%) died at follow-up. Complete procedural success was obtained in 78 (84%) patients, and clinical procedural success was obtained in 83 (89%) patients. Procedural failure was detected in 15 (16%) patients. Major and minor complications were detected in 10 (11%) and 6 (6.5%) patients, respectively. The most common minor complication was pocket hematoma. Conclusions: Our experience suggests that transvenous lead extraction has a high success rate with an acceptable risk of procedural complications. The simple manual traction method has a high rate of procedural success, despite a high dwell time of the lead.
引用
收藏
页数:12
相关论文
共 30 条
[1]   Outcomes of lead extraction without subsequent device reimplantation [J].
Al-Hijji, Mohammed A. ;
Killu, Ammar M. ;
Yousefian, Omid ;
Hodge, David O. ;
Park, Jae Yoon ;
Hebsur, Shrinivas ;
El Sabbagh, Abdallah ;
Pretorius, Victor G. ;
Ackerman, Michael J. ;
Friedman, Paul A. ;
Birgersdotter-Green, Ulrika ;
Cha, Yong-Mei .
EUROPACE, 2017, 19 (09) :1527-1534
[2]   Transvenous lead extraction at the time of cardiac implantable electronic device upgrade: Complexity, safety, and outcomes [J].
Barakat, Amr F. ;
Wazni, Oussama M. ;
Tarakji, Khaldoun ;
Saliba, Walid I. ;
Nimri, Nayef ;
Rickard, John ;
Brunner, Michael ;
Bhargava, Mandeep ;
Kanj, Mohamed ;
Baranowski, Bryan ;
Martin, David O. ;
Cantillon, Daniel ;
Callahan, Thomas ;
Dresing, Thomas ;
Niebauer, Mark ;
Chung, Mina ;
Lindsay, Bruce D. ;
Wilkoff, Bruce ;
Hussein, Ayman A. .
HEART RHYTHM, 2017, 14 (12) :1807-1811
[3]   2018 EHRA expert consensus statement on lead extraction: recommendations on definitions, endpoints, research trial design, and data collection requirements for clinical scientific studies and registries: endorsed by APHRS/HRS/LAHRS [J].
Bongiorni, Maria G. ;
Burri, Haran ;
Deharo, Jean C. ;
Starck, Christoph ;
Kennergren, Charles ;
Saghy, Laszlo ;
Rao, Archana ;
Tascini, Carlo ;
Lever, Nigel ;
Kutarski, Andrzej ;
Lozano, Ignacio Fernandez ;
Strathmore, Neil ;
Costa, Roberto ;
Epstein, Laurence ;
Love, Charles ;
Blomstrom-Lundqvist, Carina ;
Fauchier, Laurent ;
Defaye, Pascal ;
Arnar, David O. ;
Klug, Didier ;
Boveda, Serge ;
Nielsen, Jens Cosedis ;
Boriani, Giuseppe ;
Zhang, Shu ;
Martin, Andrew Paul ;
Prutkin, Jordan M. ;
de Zuloaga, Claudio .
EUROPACE, 2018, 20 (07) :1217-+
[4]   The European Lead Extraction ConTRolled (ELECTRa) study: a European Heart Rhythm Association (EHRA) Registry of Transvenous Lead Extraction Outcomes [J].
Bongiorni, Maria Grazia ;
Kennergren, Charles ;
Butter, Christian ;
Deharo, Jean Claude ;
Kutarski, Andrzej ;
Rinaldi, Christopher A. ;
Romano, Simone L. ;
Maggioni, Aldo P. ;
Andarala, Maryna ;
Auricchio, Angelo ;
Kuck, Karl-Heinz ;
Blomstrom-Lundqvist, Carina .
EUROPEAN HEART JOURNAL, 2017, 38 (40) :2995-3005
[5]   Transvenous removal of pacing and implantable cardiac defibrillating leads using single sheath mechanical dilatation and multiple venous approaches: high success rate and safety in more than 2000 leads [J].
Bongiorni, Maria Grazia ;
Soldati, Ezio ;
Zucchelli, Giulio ;
Di Cori, Andrea ;
Segreti, Luca ;
De Lucia, Raffaele ;
Solarino, Gianluca ;
Balbarini, Alberto ;
Marzilli, Mario ;
Mariani, Mario .
EUROPEAN HEART JOURNAL, 2008, 29 (23) :2886-2893
[6]   Clinical predictors of adverse patient outcomes in an experience of more than 5000 chronic endovascular pacemaker and defibrillator lead extractions [J].
Brunner, Michael P. ;
Cronin, Edmond M. ;
Duarte, Valeria E. ;
Yu, Changhong ;
Tarakji, Khaldoun G. ;
Martin, David O. ;
Callahan, Thomas ;
Cantillon, Daniel J. ;
Niebauer, Mark J. ;
Saliba, Walid I. ;
Kanj, Mohamed ;
Wazni, Oussama ;
Baranowski, Bryan ;
Wilkoff, Bruce L. .
HEART RHYTHM, 2014, 11 (05) :799-805
[7]   How adequate are the current methods of lead extraction? A review of the efficiency and safety of transvenous lead extraction methods [J].
Buiten, Maurits S. ;
van der Heijden, Aafke C. ;
Schalij, Martin J. ;
van Erven, Lieselot .
EUROPACE, 2015, 17 (05) :689-700
[8]   Trans-venous lead removal without the use of extraction sheaths, results of >250 removal procedures [J].
de Bie, Mihaly K. ;
Fouad, Doaa A. ;
Borleffs, C. Jan Willem ;
van Rees, Johannes B. ;
Thijssen, Joep ;
Trines, Serge A. ;
Bootsma, Marianne ;
Schalij, Martin J. ;
van Erven, Lieselot .
EUROPACE, 2012, 14 (01) :112-116
[9]   Predictors of 30-day and 1-year mortality after transvenous lead extraction: a single-centre experience [J].
Deckx, Sebastiaan ;
Marynissen, Thomas ;
Rega, Filip ;
Ector, Joris ;
Nuyens, Dieter ;
Heidbuchel, Hein ;
Willems, Rik .
EUROPACE, 2014, 16 (08) :1218-1225
[10]  
Elshazly Mohamed B, 2018, Card Electrophysiol Clin, V10, P667, DOI 10.1016/j.ccep.2018.04.004