MRI in Patients with Cardiovascular Implantable Electronic Devices and Fractured or Abandoned Leads

被引:1
|
作者
Greenhill, Mark J. [1 ]
Rangan, Pooja [3 ]
Su, Wilber [5 ]
Weiss, J. Peter [5 ]
Zawaneh, Michael [5 ]
Unzek, Samuel [4 ,5 ]
Tamarappoo, Balaji [4 ,5 ]
Indik, Julia [2 ]
Tung, Roderick [5 ]
Morris, Michael F. [4 ,5 ]
机构
[1] Banner Univ, Med Ctr, Dept Radiol, Tucson, AZ USA
[2] Banner Univ, Med Ctr, Div Cardiol, Tucson, AZ USA
[3] Univ Arizona, Coll Med, Div Clin Data Analyt, Phoenix, AZ USA
[4] Banner Univ, Med Ctr, Dept Radiol, 1111 E McDowell Rd, Phoenix, AZ 85006 USA
[5] Banner Univ, Med Ctr, Div Cardiol, 1111 E McDowell Rd, Phoenix, AZ 85006 USA
来源
RADIOLOGY-CARDIOTHORACIC IMAGING | 2024年 / 6卷 / 03期
关键词
PACEMAKER; SAFETY; IMPACT;
D O I
10.1148/ryct.230303
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To examine the clinical effect of lead length and lead orientation in patients with cardiac implantable electronic devices (CIEDs) and lead fragments or abandoned leads undergoing 1.5-T MRI. Materials and Methods: This Health Insurance Portability and Accountability Act-compliant retrospective study included patients with CIEDs and abandoned leads or lead fragments undergoing 1.5-T MRI from March 2014 through July 2020. CIED settings before and after MRI were reviewed, with clinically significant variations defined as a composite of the change in capture threshold of at least 50%, in sensing of at least 40%, or in lead impedance of at least 30% between before MRI and after MRI interrogation. Adverse clinical events were assessed at MRI and up to 30 days after. Univariable and multivariable analysis was performed. Results: Eighty patients with 126 abandoned CIED leads or lead fragments underwent 107 1.5-T MRI examinations. Sixty-seven patients (median age, 74 years; IQR, 66-78 years; 44 male patients, 23 female patients) had abandoned leads, and 13 (median age, 66 years; IQR, 52-74 years; nine male patients, four female patients) had lead fragments. There were no reported deaths, clinically significant arrhythmias, or adverse clinical events within 30 days of MRI. Three patients with abandoned leads had a significant change in the composite of capture threshold, sensing, or lead impedance. In a multivariable generalized estimating equation analysis, lead orientation, lead length, MRI type, and MRI duration were not associated with a significant change in the composite outcome. Conclusion: Use of 1.5-T MRI in patients with abandoned CIED leads or lead fragments of varying length and orientation was not associated with adverse clinical events.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] MRI in Patients with Cardiovascular Implantable Electronic Devices and Fractured or Abandoned Leads (vol 6, 10.1148/ryct.230303, 2024)
    Greenhill, Mark J.
    Rangan, Pooja
    Su, Wilber
    Weiss, J. Peter
    Zawaneh, Michael
    Unzek, Samuel
    Tamarappoo, Balaji
    Indik, Julia
    Tung, Roderick
    Morris, Michael F.
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2024, 6 (04):
  • [2] MRI in patients with cardiovascular implantable electronic devices
    Vieira, M. S.
    Lazoura, O.
    Nicol, E.
    Rubens, M.
    Padley, S.
    CLINICAL RADIOLOGY, 2013, 68 (09) : 928 - 934
  • [3] Magnetic Resonance Imaging in Patients With Cardiac Implantable Electronic Devices With Abandoned Leads
    Schaller, Robert D.
    Brunker, Tamara
    Riley, Michael P.
    Marchlinski, Francis E.
    Nazarian, Saman
    Litt, Harold
    JAMA CARDIOLOGY, 2021, 6 (05) : 549 - 556
  • [4] Beyond the AJR: "Magnetic Resonance Imaging in Patients With Cardiac Implantable Electronic Devices With Abandoned Leads"
    Stojanovska, Jadranka
    Ibrahim, El-Sayed
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2021, 217 (05) : 1247 - 1247
  • [5] Feasibility of Magnetic Resonance Imaging in Patients With Cardiac Implantable Electronic Devices With Epicardial or Abandoned Leads
    Gakenheimer-Smith, Lindsey
    Etheridge, Susan
    Ou, Zhining
    Presson, Angela
    Whitaker, Patricia
    Su, Jason
    Puchalski, Michael
    Asaki, Sarah Y.
    Niu, Mary
    Pilcher, Thomas
    CIRCULATION, 2018, 138
  • [6] Long-term outcomes of abandoned leads of cardiac implantable electronic devices
    Kwon, Soonil
    Lee, Euijae
    Choi, Eue-Keun
    Lee, So-Ryoung
    Oh, Seil
    Choi, Yun-Shik
    HEART RHYTHM, 2023, 20 (12) : 1639 - 1646
  • [7] MRI of Patients with Cardiac Implantable Electronic Devices
    Martinez, Jessica A.
    Ennis, Daniel B.
    CURRENT CARDIOVASCULAR IMAGING REPORTS, 2019, 12 (07)
  • [8] MRI in patients with cardiac implantable electronic devices
    Cronin, Edmond M.
    Mahon, Niall
    Wilkoff, Bruce L.
    EXPERT REVIEW OF MEDICAL DEVICES, 2012, 9 (02) : 139 - 146
  • [9] MRI in Patients with Cardiac Implantable Electronic Devices
    Muthalaly, Rahul G.
    Nerlekar, Nitesh
    Ge, Yin
    Kwong, Raymond Y.
    Nasis, Arthur
    RADIOLOGY, 2018, 289 (02) : 281 - 292
  • [10] MRI of Patients with Cardiac Implantable Electronic Devices
    Jessica A. Martinez
    Daniel B. Ennis
    Current Cardiovascular Imaging Reports, 2019, 12