Improving the experimental estimation of the incident angle modifier of evacuated tube solar collectors with heat pipes

被引:1
|
作者
Rodriguez-Munoz, J. M. [1 ]
Bove, I. [2 ]
Alonso-Suarez, R. [1 ,2 ]
机构
[1] Univ Republica, Dept Fis Litoral, Lab Energia Solar, CENUR Litoral Norte, Montevideo, Uruguay
[2] Univ Republica, Fac Ingn, Lab Energia Solar, Inst Fis, Montevideo, Uruguay
关键词
Solar thermal collector; Incident angle modifier; Evacuated tube; ISO; 9806; standard; DYNAMIC TEST METHOD; THERMAL PERFORMANCE; MODEL;
D O I
10.1016/j.renene.2024.121240
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This article focuses on the thermal performance testing of evacuated tube solar collectors with heat pipes (ETC-HP) using the ISO 9806:2017 standard test methods: Steady-state testing (SST) and Quasi-dynamic testing (QDT). The main objective of this work is to improve the experimental estimation of the incident angle modifier (IAM) for these types of solar collectors in both test methods. For the QDT method, a novel model for the IAM is presented and validated against SST results. This IAM model, recently developed for flat plate collectors under the SST framework, has demonstrated superior performance compared to other available models. This study marks its first application to ETC-HP technology, showcasing its adaptability across different technologies and test methods. While this work primarily focuses on ETC-HP collectors, the results are applicable to evacuated tubes in general. Thus, the generality of this model and its consistency with the SST method make it suitable for implementation in test standards as a general-purpose model. Regarding the SST method, and aiming to enhance consistency between testing methods, an improved parameter conversion from SST to QDT is also proposed, reducing IAM differences between test methods by 1 to 19 percentage points, with greater improvement at higher incidence angles.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Design of Evacuated Tube Solar Collector with Heat Pipe
    Kumar, S. Siva
    Kumar, K. Mohan
    Kumar, S. R. Sanjeev
    MATERIALS TODAY-PROCEEDINGS, 2017, 4 (14) : 12641 - 12646
  • [22] An experimental investigation of the phase change process effects on the system performance for the evacuated tube solar collectors integrated with PCMs
    Essa, Mohamed A.
    Mostafa, Nabil H.
    Ibrahim, Mostafa M.
    ENERGY CONVERSION AND MANAGEMENT, 2018, 177 : 1 - 10
  • [23] MEASUREMENT OF THE EFFICIENCY OF EVACUATED TUBE SOLAR COLLECTORS UNDER VARIOUS OPERATING CONDITIONS
    Zubriski, S. E.
    Dick, K. J.
    JOURNAL OF GREEN BUILDING, 2012, 7 (03): : 114 - 130
  • [24] On the effect of storage tank type on the performance of evacuated tube solar collectors: Solar radiation prediction analysis and case study
    Sadeghi, Gholamabbas
    Pisello, Anna Laura
    Safarzadeh, Habibollah
    Poorhossein, Miad
    Jowzi, Mohammad
    ENERGY, 2020, 198
  • [25] Experimental and theoretical performance analysis of PVT-evacuated U-tube solar collectors with and without CPC integration
    Daghigh, Roonak
    Arshad, Siamand Azizi
    ENERGY, 2025, 320
  • [26] Validated mathematical models of a solar water heater system with thermosyphon evacuated tube collectors
    Wannagosit, C.
    Sakulchangsatjatai, P.
    Kammuang-lue, N.
    Terdtoon, P.
    CASE STUDIES IN THERMAL ENGINEERING, 2018, 12 : 528 - 536
  • [27] Towards an energy efficiency optimization of solar horizontal storage tanks and circulation pipes integrating evacuated tube collectors through CFD parametric studies
    Bouhal, T.
    Fertahi, Saif ed-Din
    Agrouaz, Y.
    El Rhafiki, T.
    Zeraouli, Y.
    Jamil, A.
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2018, 26 : 93 - 104
  • [28] Validated TRNSYS model for forced circulation solar water heating systems with flat plate and heat pipe evacuated tube collectors
    Ayompe, L. M.
    Duffy, A.
    McCormack, S. J.
    Conlon, M.
    APPLIED THERMAL ENGINEERING, 2011, 31 (8-9) : 1536 - 1542
  • [29] The Experimental Investigation of a Solar Still Coupled with an Evacuated Tube Collector
    Sampathkumar, K.
    Arjunan, T. V.
    Senthilkumar, P.
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2013, 35 (03) : 261 - 270
  • [30] Experimental, numerical and analytical investigation of a U-type evacuated tube collectors' array
    Korres, Dimitrios N.
    Tzivanidis, Christos
    Koronaki, Irene P.
    Nitsas, Michael T.
    RENEWABLE ENERGY, 2019, 135 : 218 - 231