Strength of titanium-zirconium alloy implants with a conical connection after implantoplasty

被引:2
|
作者
Shah, Sweety D. [1 ]
Zheng, Fengyuan [2 ]
Seghi, Robert R. [3 ]
Lee, Damian J. [1 ]
机构
[1] Ohio State Univ, Coll Dent, Adv Prosthodont Program, Div Restorat & Prosthet Dent, Columbus, OH USA
[2] Univ Minnesota, Sch Dent, Dept Restorat Sci, Adv Educ Prosthodont Program, Minneapolis, MN USA
[3] Ohio State Univ, Coll Dent, Div Restorat & Prosthet Dent, Columbus, OH USA
关键词
3-YEAR CLINICAL-TRIAL; SHAPED ORAL IMPLANTS; PERI-IMPLANTITIS; SURFACE-ROUGHNESS; MECHANICAL-PROPERTIES; RESECTIVE SURGERY; TACTILE FUNCTION; DENTAL IMPLANTS; IN-VIVO; THERAPY;
D O I
10.1016/j.prosdent.2022.08.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem.Peri-implantitis occurs around dental implants, and implantoplasty hasbeen used to address this ongoing disease; however, the changes to the physical properties ofan implant after implantoplasty have not been well documented. Purpose.The purpose of this in vitro study was to determine the effect of implantoplasty onfracture strength and the load required for plastic deformation after cyclic fatigue on dentalimplants. Material and methods.Twenty-six titanium/zirconium (TiZr) alloy implants (Roxolid Bone LevelImplant; 4.1x10 mm) were embedded with 50% thread exposure and divided into 4 groupsbased on whether they had implantoplasty treatment by using different diamond rotaryinstruments and/or cyclic loading at 250 N for 2 million cycles: C0 (control, no cyclic loading), T0(test, no cyclic loading), CM (control, cyclic loading), and TM (test, cyclic loading). Afterimplantoplasty and/or cyclic loading, all implants underwent a load-to-failure test. The maximumfracture strength (FS) and load required for the onset of plastic deformation (PD) were recordedin Newtons. One-way ANOVA and nonparametric comparisons with control by using the Dunnand Wilcoxon method for joint ranking were used for statistical analysis. Results.The mean +/- standard deviation FS for C0, CM, T0, and TM was 1465.2 +/- 86.4 N, 1480.7 +/- 64.1N, 1299.3 +/- 123.8 N, and 1252.1 +/- 85.7 N, respectively. The mean +/- standard deviation load for onsetof PD for C0, CM, T0, and TM was 860.2 +/- 88.1 N, 797.0 +/- 130.5 N, 776.5 +/- 181.8 N, and 631.3 +/- 84.5 N,respectively. The TM group had a significantly lower FS and PD than the C0, CM, and T0 groups(P<.05) Conclusions.Both fracture strength (FS) and the onset of plastic deformation (PD) weresignificantly reduced after a TiZr alloy implant received implantoplasty and cyclic loading. (JProsthet Dent 2024;132:593-9)
引用
收藏
页码:593 / 599
页数:7
相关论文
共 50 条
  • [31] Influence of titanium and titanium-zirconium alloy as implant materials on implant stability of maxillary implant retained overdenture: a randomized clinical trial
    Abd El-Hady, Amany Ibrahim
    Eid, Hany Ibrahim
    Mohamed, Shaimaa Lotfy
    Fadl, Sawsan Maged
    BMC ORAL HEALTH, 2024, 24 (01):
  • [32] Titanium-zirconium narrow-diameter versus titanium regular-diameter implants for anterior and premolar single crowns: 3-year results of a randomized controlled clinical study
    Ioannidis, Alexis
    Gallucci, German O.
    Jung, Ronald E.
    Borzangy, Sary
    Haemmerle, Christoph H. F.
    Benic, Goran I.
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2015, 42 (11) : 1060 - 1070
  • [33] Titanium-zirconium narrow-diameter versus titanium regular-diameter implants for anterior and premolar single crowns: 1-year results of a randomized controlled clinical study
    Benic, Goran I.
    Gallucci, German O.
    Mokti, Muizzaddin
    Haemmerle, Christoph H. F.
    Weber, Hans-Peter
    Jung, Ronald E.
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2013, 40 (11) : 1052 - 1061
  • [34] One-year results of maxillary overdentures supported by 2 titanium-zirconium implants - implant survival rates and radiographic outcomes
    Zembic, Anja
    Tahmaseb, Ali
    Jung, Ronald E.
    Wismeijer, Daniel
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (07) : e60 - e67
  • [35] Clinical performance of monolithic zirconia crowns on titanium-zirconium reduced-diameter implants in the molar area: Interim data at three years of a randomized controlled trial
    Zumstein, K.
    Waller, T.
    Hammerle, C. H. F.
    Jung, R. E.
    Benic, G.
    Muhlemann, S.
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (12) : 1354 - 1362
  • [36] Changes in masticatory performance and bite force after treatment with mandibular overdentures retained by four titanium-zirconium mini implants: One-year randomised clinical trial
    Leles, Claudio Rodrigues
    Curado, Thalita Fernandes Fleury
    Nascimento, Lays Noleto
    Silva, Jesio Rodrigues
    de Paula, Marcella Silva
    McKenna, Gerald
    Schimmel, Martin
    JOURNAL OF ORAL REHABILITATION, 2024, 51 (08) : 1459 - 1467
  • [37] The Impact of Force Transmission on Narrow-Body Dental Implants Made of Commercially Pure Titanium and Titanium Zirconia Alloy with a Conical Implant-Abutment Connection: An Experimental Pilot Study
    Nelson, Katja
    Schmelzeisen, Rainer
    Taylor, Thomas D.
    Zabler, Simon
    Wiest, Wolfram
    Fretwurst, Tobias
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (05) : 1066 - 1071
  • [38] Small-diameter titanium grade IV and titanium-zirconium implants in edentulous mandibles: Ten-year results from a double-blind, randomised controlled split-mouth core-trial
    Mueller, Frauke
    Al-Nawas, Bilal
    Storelli, Stefano
    Quirynen, Marc
    Hicklin, Stefan
    Castro-Laza, Jose
    Bassetti, Mario
    Srinivasan, Murali
    Roxolid Study Grp
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, : 77 - 88
  • [39] Small-diameter titanium grade IV and titanium-zirconium implants in edentulous mandibles: five-year results from a double-blind, randomized controlled trial
    Mueller, Frauke
    Al-Nawas, Bilal
    Storelli, Stefano
    Quirynen, Marc
    Hicklin, Stefan
    Castro-Laza, Jose
    Bassetti, Renzo
    Schimmel, Martin
    BMC ORAL HEALTH, 2015, 15
  • [40] Small-diameter titanium Grade IV and titanium-zirconium implants in edentulous mandibles: three-year results from a double-blind, randomized controlled trial
    Quirynen, Marc
    Al-Nawas, Bilal
    Meijer, Henny J. A.
    Razavi, Amir
    Reichert, Torsten E.
    Schimmel, Martin
    Storelli, Stefano
    Romeo, Eugenio
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (07) : 831 - 840