Concurrent validity of inertial measurement units in range of motion measurements of upper extremity: A systematic review and meta-analysis

被引:0
作者
Li, Jinfeng [1 ]
Qiu, Fanji [2 ]
Gan, Liaoyan [3 ]
Chou, Li-Shan [1 ]
机构
[1] Iowa State Univ, Dept Kinesiol, Ames, IA 50011 USA
[2] Humboldt Univ, Inst Sport Sci, Movement Biomech, Berlin, Germany
[3] Univ Alberta, Coll Hlth Sci, Fac Kinesiol Sport & Recreat, Edmonton, AB, Canada
来源
WEARABLE TECHNOLOGIES | 2024年 / 5卷
关键词
Inertial Measurement Unit (IMU); Movement Analysis; Upper Extremity; UPPER-LIMB; VALIDATION; KINEMATICS; ACCURACY; CAPTURE; REPEATABILITY; RELIABILITY; CALIBRATION;
D O I
10.1017/wtc.2024.6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Inertial measurement units (IMUs) have proven to be valuable tools in measuring the range of motion (RoM) of human upper limb joints. Although several studies have reported on the validity of IMUs compared to the gold standard (optical motion capture system, OMC), a quantitative summary of the accuracy of IMUs in measuring RoM of upper limb joints is still lacking. Thus, the primary objective of this systematic review and meta-analysis was to determine the concurrent validity of IMUs for measuring RoM of the upper extremity in adults. Fifty-one articles were included in the systematic review, and data from 16 were pooled for meta-analysis. Concurrent validity is excellent for shoulder flexion-extension (Pearson's r = 0.969 [0.935, 0.986], ICC = 0.935 [0.749, 0.984], mean difference = -3.19 (p = 0.55)), elbow flexion-extension (Pearson's r = 0.954 [0.929, 0.970], ICC = 0.929 [0.814, 0.974], mean difference = 10.61 (p = 0.36)), wrist flexion-extension (Pearson's r = 0.974 [0.945, 0.988], mean difference = -4.20 (p = 0.58)), good to excellent for shoulder abduction-adduction (Pearson's r = 0.919 [0.848, 0.957], ICC = 0.840 [0.430, 0.963], mean difference = -7.10 (p = 0.50)), and elbow pronation-supination (Pearson's r = 0.966 [0.939, 0.981], ICC = 0.821 [0.696, 0.900]). There are some inconsistent results for shoulder internal-external rotation (Pearson's r = 0.939 [0.894, 0.965], mean difference = -9.13 (p < 0.0001)). In conclusion, the results support IMU as a viable instrument for measuring RoM of upper extremity, but for some specific joint movements, such as shoulder rotation and wrist ulnar-radial deviation, IMU measurements need to be used with caution.
引用
收藏
页数:35
相关论文
共 50 条
  • [1] Validity and Reliability of Inertial Measurement Units on Lower Extremity Kinematics During Running: A Systematic Review and Meta-Analysis
    Zeng, Ziwei
    Liu, Yue
    Hu, Xiaoyue
    Tang, Meihua
    Wang, Lin
    SPORTS MEDICINE-OPEN, 2022, 8 (01)
  • [2] Validity and Reliability of Inertial Measurement Units on Lower Extremity Kinematics During Running: A Systematic Review and Meta-Analysis
    Ziwei Zeng
    Yue Liu
    Xiaoyue Hu
    Meihua Tang
    Lin Wang
    Sports Medicine - Open, 2022, 8
  • [3] Validity of inertial measurement units for tracking human motion: a systematic review
    Ghattas, John
    Jarvis, Danielle N.
    SPORTS BIOMECHANICS, 2021, : 1853 - 1866
  • [4] Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity
    Al-Amri, Mohammad
    Nicholas, Kevin
    Button, Kate
    Sparkes, Valerie
    Sheeran, Liba
    Davies, Jennifer L.
    SENSORS, 2018, 18 (03):
  • [5] Measurement of Upper Limb Range of Motion Using Wearable Sensors: A Systematic Review
    Walmsley, Corrin P.
    Williams, Sian A.
    Grisbrook, Tiffany
    Elliott, Catherine
    Imms, Christine
    Campbell, Amity
    SPORTS MEDICINE-OPEN, 2018, 4
  • [6] Validity and reliability of inertial measurement units on gait, static balance and functional mobility performance among community-dwelling older adults: a systematic review and meta-analysis
    Yine, Lulu
    Xu, Xin
    Wang, Ruiyan
    Li, Feifei
    Wang, Yushan
    Wang, Lin
    EFORT OPEN REVIEWS, 2025, 10 (04) : 172 - 185
  • [7] Reliability and validity varies among smartphone apps for range of motion measurements of the lower extremity: a systematic review
    Hahn, Sarah
    Kroeger, Inga
    Willwacher, Steffen
    Augat, Peter
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2021, 66 (06): : 537 - 555
  • [8] Lower extremity range of motion and alignment: A reliability and concurrent validity study of goniometric and three-dimensional motion analysis measurement
    Ore, Viktor
    Nasic, Salmir
    Riad, Jacques
    HELIYON, 2020, 6 (08)
  • [9] Shoulder Range of Motion Measurement Using Inertial Measurement Unit-Concurrent Validity and Reliability
    Kaszynski, Jakub
    Baka, Cezary
    Bialecka, Martyna
    Lubiatowski, Przemyslaw
    SENSORS, 2023, 23 (17)
  • [10] Systematic Review and Meta-Analysis of Global Neuroma Incidence in Upper Extremity Amputees
    Chaker, Sara C.
    Hung, Ya-Ching
    Saad, Mariam
    Cardenas, David
    Perdikis, Galen
    Thayer, Wesley P.
    ANNALS OF PLASTIC SURGERY, 2024, 92 (01) : 80 - 85