Comparison of medical image interpretation time between conventional and automated methods of breast ultrasound

被引:0
|
作者
Alves, Katyane Larissa [1 ]
Freitas-Junior, Ruffo [1 ]
Paulinelli, Regis Resende [1 ]
Borges, Marcus Nascimento [1 ]
机构
[1] Univ Fed Goias, Goiania, Go, Brazil
来源
REVISTA BRASILEIRA DE GINECOLOGIA E OBSTETRICIA | 2024年 / 46卷
关键词
Breast ultrasound; Diagnostic imaging; Breast neoplasms; Three-dimensional imaging; WOMEN; CANCER; MAMMOGRAPHY;
D O I
10.61622/rbgo/2024AO15
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To compare the medical image interpretation's time between the conventional and automated methods of breast ultrasound in patients with breast lesions. Secondarily, to evaluate the agreement between the two methods and interobservers. Methods: This is a cross-sectional study with prospective data collection. The agreement's degrees were established in relation to the breast lesions's ultrasound descriptors. To determine the accuracy of each method, a biopsy of suspicious lesions was performed, considering the histopathological result as the diagnostic gold standard. Results: We evaluated 27 women. Conventional ultrasound used an average medical time of 10.77 minutes [ +/- 2.55] greater than the average of 7.38 minutes [ +/- 2.06] for automated ultrasound [p<0.001]. The degrees of agreement between the methods ranged from 0.75 to 0.95 for researcher 1 and from 0.71 to 0.98 for researcher 2. Among the researchers, the degrees of agreement were between 0.63 and 1 for automated ultrasound and between 0.68 and 1 for conventional ultrasound. The area of the ROC curve for the conventional method was 0.67 [p=0.003] for researcher 1 and 0.72 [p<0.001] for researcher 2. The area of the ROC curve for the automated method was 0. 69 [p=0.001] for researcher 1 and 0.78 [p<0.001] for researcher 2. Conclusion: We observed less time devoted by the physician to automated ultrasound compared to conventional ultrasound, maintaining accuracy. There was substantial or strong to perfect interobserver agreement and substantial or strong to almost perfect agreement between the methods.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Comparison of conventional and automated breast volume ultrasound in the description and characterization of solid breast masses based on BI-RADS features
    Kim, Hyunji
    Cha, Joo Hee
    Oh, Ha-Yeun
    Kim, Hak Hee
    Shin, Hee Jung
    Chae, Eun Young
    BREAST CANCER, 2014, 21 (04) : 423 - 428
  • [22] Diagnostic performance of coronal view in comparison with transverse view of three-dimensional automated breast ultrasound
    Suzuki, Megumi
    Nakayama, Ryohei
    Namba, Kiyoshi
    Kawami, Hiroyuki
    Nara, Mayumi
    Smathers, Ralph L.
    Nakamura, Seigo
    ACTA RADIOLOGICA, 2021, 62 (01) : 27 - 33
  • [23] Automated linking of suspicious findings between automated 3D breast ultrasound volumes
    Gubern-Merida, Albert
    Tan, Tao
    van Zelsta, Jan
    Mann, Ritse M.
    Karssemeijer, Nico
    MEDICAL IMAGING 2016: COMPUTER-AIDED DIAGNOSIS, 2015, 9785
  • [24] Comparison between automated breast volume scanner (ABVS) versus hand-held ultrasound as a second look procedure after magnetic resonance imaging
    Girometti, Rossano
    Zanotel, Martina
    Londero, Viviana
    Bazzocchi, Massimo
    Zuiani, Chiara
    EUROPEAN RADIOLOGY, 2017, 27 (09) : 3767 - 3775
  • [25] Characterization of breast masses: a comparative study between automated breast ultrasound (ABUS) and digital breast tomosynthesis (DBT)
    Hashem, Lamiaa Mohamed Bassam
    Ali, Reham Hussein Mohamed
    Helal, Maha Hussein
    Gemeae, Emad ELdin E. L.
    Moustafa, Amr Farouk Ibrahim
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2020, 51 (01)
  • [26] Comparison of Conventional Ultrasound and Contrast-Enhanced Ultrasound in Breast Invasive Ductal Carcinoma in Different T Stages
    Wang, Z. Y.
    Zhu, Y. C.
    Zhou, Q. C.
    Xie, Y. Q.
    Liu, J.
    Hu, J. N.
    Tang, S. C.
    Li, J. J.
    Zhang, Y.
    Xiao, Y. M.
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2015, 5 (08) : 1968 - 1972
  • [27] Comparison and Combination of Two Ultrasound Modalities, Handheld Ultrasound and Automated Breast Volume Scanner, With and Without Knowledge of MRI
    Kim, Yoonsoo
    Kang, Bong Joo
    Kim, Sung Hun
    Lee, Eun Jae
    IRANIAN JOURNAL OF RADIOLOGY, 2018, 15 (02)
  • [28] Medical Knowledge Constrained Semantic Breast Ultrasound Image Segmentation
    Huang, Kuan
    Cheng, H. D.
    Zhang, Yingtao
    Zhang, Boyu
    Xing, Ping
    Ning, Chunping
    2018 24TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION (ICPR), 2018, : 1193 - 1198
  • [29] A comparison of image interpretation times in Full Field Digital Mammography and Digital Breast Tomosynthesis
    Astley, Susan
    Connor, Sophie
    Lim, Yit
    Tate, Catriona
    Entwistle, Helen
    Morris, Julie
    Whiteside, Sigrid
    Sergeant, Jamie
    Wilson, Mary
    Beetles, Ursula
    Boggis, Caroline
    Gilbert, Fiona
    MEDICAL IMAGING 2013: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2013, 8673
  • [30] Comparison of handheld ultrasound and automated breast ultrasound in women recalled after mammography screening
    Hellgren, Roxanna
    Dickman, Paul
    Leifland, Karin
    Saracco, Ariel
    Hall, Per
    Celebioglu, Fuat
    ACTA RADIOLOGICA, 2017, 58 (05) : 515 - 520