Study on Wind Vibration Response and Coupling Effect of Transmission Tower-Line System Under Downburst

被引:2
|
作者
Zhong, Yongli [1 ]
Liu, Yichen [1 ]
Li, Shun [2 ]
Yan, Zhitao [1 ,3 ]
Liu, Xinpeng [1 ]
机构
[1] Chongqing Univ Sci & Technol, Sch Civil Engn & Architecture, Chongqing 401331, Peoples R China
[2] Chongqing IAT Automobile Res Inst Co Ltd, Chongqing 401121, Peoples R China
[3] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
来源
IEEE ACCESS | 2024年 / 12卷
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Poles and towers; Couplings; Wind speed; Vibrations; History; Atmospheric modeling; Numerical models; Computational fluid dynamics; Downburst; computational fluid dynamics (CFD); transmission tower-line system; wind-induced vibration response; tower-line coupling effect; NUMERICAL-SIMULATION; MICROBURST; TORNADO;
D O I
10.1109/ACCESS.2024.3422032
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Downburst is a type of near-surface short-term destructive strong wind that significantly affects wind-sensitive flexible structures like transmission tower-line systems. The existence of the tower-line coupling effect complicates the wind-induced vibration response analysis. Firstly, the average wind speed time history is obtained using the impinging jet wind field model, the pulsating wind speed time history is simulated using the harmonic synthesis method, and then the total wind speed time history of the downburst is obtained by superposition. Then, the transmission tower-line finite element model is established to carry out the wind vibration response analysis under different wind attack angles. Based on the most unfavorable wind angle of attack, the wind-induced vibration response and the coupling effect of the tower-line system are investigated under different maximum wind speed heights (Z(max)) and span distances. Finally, the range of wind load reduction coefficients for the tower-line separation system is given. The results show that under the most unfavorable wind angle of attack angle, both the displacement and acceleration response of the tower-line separation system are more significant than that of the tower-line coupling system. At Z(max )= 70m, the difference in displacement response between the two systems reaches the maximum, indicating an apparent tower-line coupling effect. As the span distance increases, both the displacement response and the acceleration response of the tower-line separation system increase. In contrast, the displacement response of the tower-line coupling system increases, but the acceleration response decreases. For the proposed design reduction coefficient for the transmission tower-line coupling effect under the action of the downburst, it is considered more reasonable to take the value between 0.83-0.95. This study provides some references for further optimization of the transmission tower design.
引用
收藏
页码:100120 / 100133
页数:14
相关论文
共 50 条
  • [1] Study on Wind-Induced Response of Transmission Tower-Line System under Downburst Wind
    Fang, Zhiyuan
    Wang, Zhisong
    Zhu, Renyu
    Huang, Hanjie
    BUILDINGS, 2022, 12 (07)
  • [2] Study on Stability of Transmission Tower-Line System under a Downburst
    Zhong, Yongli
    Li, Shun
    Yan, Zhitao
    Liu, Xinpeng
    Luo, Jun
    Jin, Weichen
    BUILDINGS, 2022, 12 (09)
  • [3] Nonlinear inelastic responses of transmission tower-line system under downburst wind
    Yang, S. C.
    Hong, H. P.
    ENGINEERING STRUCTURES, 2016, 123 : 490 - 500
  • [4] Study on the collapse failure of transmission tower-line system under downburst
    Bi W.-Z.
    Tian L.
    Gongcheng Lixue/Engineering Mechanics, 2022, 39 : 78 - 83
  • [5] Study of Wind Induced Vibration of Transmission Power Tower-line System
    Yang, Weijun
    Liang, Longteng
    APPLIED MECHANICS, MATERIALS AND MANUFACTURING IV, 2014, 670-671 : 1125 - 1129
  • [6] Nonlinear stochastic response of transmission tower-line system under strong wind
    Wang, Da-Hai
    Li, Jie
    Zhendong yu Chongji/Journal of Vibration and Shock, 2010, 29 (06): : 62 - 65
  • [7] Wind Tunnel Testing on Coupling Mechanism of Wind-induced Vibration of Transmission Tower-line System
    Wang D.
    Xiang X.
    Zhang Z.
    Zhang D.
    Wang W.
    Dianwang Jishu/Power System Technology, 2022, 46 (01): : 343 - 352
  • [8] Study on the influence of insulator on the coupling effect of transmission tower-line system
    Gao, Qingshui
    Liu, Shi
    Yang, Yi
    Zhang, Chu
    2018 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS AND CONTROL ENGINEERING (ISPECE 2018), 2019, 1187
  • [9] Dynamic Response Modeling of Mountain Transmission Tower-Line Coupling System under Wind-Ice Load
    Song, Haoran
    Li, Yingna
    BUILDINGS, 2023, 13 (03)
  • [10] Wind Tunnel Study on Wind-Induced Vibration Responses of a UHV Transmission Tower-Line System
    Deng, H. Z.
    Si, R. J.
    Hu, X. Y.
    Duan, C. Y.
    ADVANCES IN STRUCTURAL ENGINEERING, 2013, 16 (07) : 1175 - 1185