Failure mechanism of transversely isotropic schist under Brazilian test using real-time X-ray nano tomography scanning

被引:1
|
作者
Aliabadian, Zeinab [1 ]
Sainoki, Atsushi [2 ,3 ]
Sharafisafa, Mansour [4 ]
机构
[1] KN Toosi Univ Technol, Civil Engn Fac, Tehran, Iran
[2] Kumamoto Univ, Fac Adv Sci & Technol, Kumamoto, Japan
[3] Kumamoto Univ, Int Res Org Adv Sci & Technol, Kumamoto, Japan
[4] Univ Tehran, Coll Engn, Sch Min Engn, Tehran, Iran
基金
日本学术振兴会;
关键词
3D progressive failure mechanism; Anisotropic rock; In-situ Brazilian test; Nano X-ray computed tomography; Digital volume correlation; UNIAXIAL COMPRESSION; SANDSTONE; ROCK; IMAGES;
D O I
10.1016/j.engfracmech.2024.110465
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The study tries to address Brazilian tests on a transversely isotropic rock to investigate failure conditions by using digital volume correlation (DVC). For this purpose, an in-situ Brazilian apparatus in a nano- X-ray computed tomography (CT) scanner is applied to investigate the 3D progressive failure mechanism of the schist. Two different anisotropy angles are tested. CT scans are conducted at every selected loading stage before peak load. DVC analyzes the constructed Xray CT images to determine the effect of schistosity orientation on failure mechanism, including crack initiation and propagation. A calibration method is presented to verify DVC parameters, including the half size of the correlation window and the space between two sub-volumes. Using DVC, 3D deviatoric strain field, strain contours, and displacement increment are determined at all stages of loading. A CT value-based method (VG Studio) is also applied to validate the DVC results. It is found that the layer boundaries affect the failure pattern, with the agreement between the DVC results and VG Studio results being observed. For the specimen with horizontal layers, the crack initiates at the center part at the lower density layer and finishes out of the center. Also, for the specimen with horizontal layers, the crack initiates and propagates at the boundary of two layers out of the middle line of the specimen. These asymmetry failures are due to the heterogeneity of layers. The study also shows the type of failure using DVC by monitoring displacement increment vectors near the crack location.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] In-situ understanding of pore nucleation and growth in polyurethane foams by using real-time synchrotron X-ray tomography
    Perez-Tamarit, S.
    Solorzano, E.
    Mokso, R.
    Rodriguez-Perez, M. A.
    POLYMER, 2019, 166 : 50 - 54
  • [32] Polymorphism of milk fat studied by differential scanning calorimetry and real-time X-ray powder diffraction
    ten Grotenhuis, E
    van Aken, GA
    van Malssen, KF
    Schenk, H
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1999, 76 (09) : 1031 - 1039
  • [33] Real-Time Scanning Beam Digital X-ray Image Guidance System for Transbronchial Needle Biopsy
    Yoon, Sungwon
    Wilfley, Brian P.
    Jasperson, Keith
    Krishna, Ganesh
    Fahrig, Rebecca
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [34] Micro/nano X-ray tomography reconstruction fine-tuning using scanning electron microscope images
    Ostadi, H.
    Jiang, K.
    Prewett, P. D.
    MICRO & NANO LETTERS, 2008, 3 (04) : 106 - 109
  • [35] Evaluation of Meso-damage Processes in Concrete by X-Ray CT Scanning Techniques Under Real-Time Uniaxial Compression Testing
    Wei Tian
    Nv Han
    Journal of Nondestructive Evaluation, 2019, 38
  • [36] Evaluation of Meso-damage Processes in Concrete by X-Ray CT Scanning Techniques Under Real-Time Uniaxial Compression Testing
    Tian, Wei
    Han, Nv
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2019, 38 (02)
  • [37] A QUASI REAL-TIME APPROACH TO INVESTIGATING THE DAMAGE AND FRACTURE PROCESS IN PLAIN CONCRETE BY X-RAY TOMOGRAPHY
    Qin Yuan
    Chai Junrui
    Ding Weihua
    Dang Faning
    Lei Man
    Xu Zengguang
    JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2016, 22 (06) : 792 - 799
  • [38] Hysteroscopic Management of the Fully Embedded IUD Using Real-Time Intraoperative X-Ray
    Bender, L.
    Kwon, C.
    Schiff, L.
    OBSTETRICS AND GYNECOLOGY, 2025, 145 (5S): : 132S - 132S
  • [39] Real-time automated counterfeit integrated circuit detection using x-ray microscopy
    Mahmood, Kaleel
    Carmona, Pedro Latorre
    Shahbazmohamadi, Sina
    Pla, Filiberto
    Javidi, Bahram
    APPLIED OPTICS, 2015, 54 (13) : D25 - D32
  • [40] Process control in aluminum foam production using real-time X-ray radioscopy
    Stanzick, H
    Wichmann, M
    Weise, J
    Helfen, L
    Baumbach, T
    Banhart, J
    ADVANCED ENGINEERING MATERIALS, 2002, 4 (10) : 814 - 823