Failure mechanism of transversely isotropic schist under Brazilian test using real-time X-ray nano tomography scanning

被引:1
|
作者
Aliabadian, Zeinab [1 ]
Sainoki, Atsushi [2 ,3 ]
Sharafisafa, Mansour [4 ]
机构
[1] KN Toosi Univ Technol, Civil Engn Fac, Tehran, Iran
[2] Kumamoto Univ, Fac Adv Sci & Technol, Kumamoto, Japan
[3] Kumamoto Univ, Int Res Org Adv Sci & Technol, Kumamoto, Japan
[4] Univ Tehran, Coll Engn, Sch Min Engn, Tehran, Iran
基金
日本学术振兴会;
关键词
3D progressive failure mechanism; Anisotropic rock; In-situ Brazilian test; Nano X-ray computed tomography; Digital volume correlation; UNIAXIAL COMPRESSION; SANDSTONE; ROCK; IMAGES;
D O I
10.1016/j.engfracmech.2024.110465
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The study tries to address Brazilian tests on a transversely isotropic rock to investigate failure conditions by using digital volume correlation (DVC). For this purpose, an in-situ Brazilian apparatus in a nano- X-ray computed tomography (CT) scanner is applied to investigate the 3D progressive failure mechanism of the schist. Two different anisotropy angles are tested. CT scans are conducted at every selected loading stage before peak load. DVC analyzes the constructed Xray CT images to determine the effect of schistosity orientation on failure mechanism, including crack initiation and propagation. A calibration method is presented to verify DVC parameters, including the half size of the correlation window and the space between two sub-volumes. Using DVC, 3D deviatoric strain field, strain contours, and displacement increment are determined at all stages of loading. A CT value-based method (VG Studio) is also applied to validate the DVC results. It is found that the layer boundaries affect the failure pattern, with the agreement between the DVC results and VG Studio results being observed. For the specimen with horizontal layers, the crack initiates at the center part at the lower density layer and finishes out of the center. Also, for the specimen with horizontal layers, the crack initiates and propagates at the boundary of two layers out of the middle line of the specimen. These asymmetry failures are due to the heterogeneity of layers. The study also shows the type of failure using DVC by monitoring displacement increment vectors near the crack location.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] REAL-TIME X-RAY INSPECTION SYSTEM FOR FAST FLUX TEST FACILITY FUEL
    JACKSON, CN
    GRAY, WH
    SHAW, CB
    MATERIALS EVALUATION, 1973, 31 (10) : 199 - 204
  • [22] FPGA-Based Real-Time Data Acquisition for Ultrafast X-Ray Computed Tomography
    Windisch, Dominic
    Knodel, Oliver
    Juckeland, Guido
    Hampel, Uwe
    Bieberle, Andre
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2021, 68 (12) : 2779 - 2786
  • [23] Real-Time Observation of Film Structure Using X-ray Waveguide Phenomenon
    Hayashi, Kouichi
    Hu, Wen
    Nakamura, Takahiro
    Takenaka, Hisataka
    Suzuki, Kosuke
    Ito, Masahisa
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2009, 48 (11)
  • [24] A real-time X-ray image sensor using a thallium bromide photoconductor
    Ouimette, DR
    Iodice, RM
    Kung, PJ
    Lynds, L
    MEDICAL APPLICATIONS OF PENETRATING RADIATION, 1999, 3770 : 156 - 163
  • [25] Real-time observation of electrorheological fluids using synchrotron X-ray imaging
    Yoon, Seok Ho
    Seol, Seung Kwon
    Je, Jung Ho
    Kim, Hun-Sik
    Choi, Hyoung Jin
    Jin, Hyoung-Joon
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2008, 313 : 557 - 561
  • [26] Non-destructive testing using real-time X-ray technology
    不详
    INSIGHT, 1996, 38 (05) : 325 - 325
  • [27] IMPROVED REAL-TIME X-RAY TECHNOLOGY WIDENS THE HORIZONS OF INDUSTRIAL COMPUTER-TOMOGRAPHY
    DRAKE, SG
    BRITISH JOURNAL OF NON-DESTRUCTIVE TESTING, 1993, 35 (10): : 580 - 583
  • [28] Integration of X-Ray and Optical Tomography for Precision Radiation Guidance and Real-Time Treatment Evaluation
    Yang, Y.
    Wang, K.
    Eslami, S.
    Iordachita, I.
    Patterson, M.
    Wong, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [29] Evaluation of X-ray Fluorescence Emission Tomography for Real-time Assessment of Photodynamic Therapy Effect
    George, Jonathan
    Groll, Andrew
    Cheng, Shih-Hsun
    Chen, Chin-Tu
    La Riviere, Patrick
    Lo, Leu-Wei
    Souris, Jeffrey
    Meng, Ling-Jian
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [30] Real-time X-ray scattering from a nylon fiber under strain.
    Chang, H
    Londono, JD
    Davidson, RV
    Wu, J
    Guise, GW
    Quintana, JP
    Ginnard, CR
    Leach, RA