Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit

被引:0
|
作者
Alcala, Glasiele C. [1 ]
Ekkapat, Gamonmas [1 ,2 ]
Medeiros, Kyle J. [1 ]
Morais, C. A. [1 ]
Xin, Yi [1 ]
Giammatte, Valentina [1 ,3 ]
Bruno, Giovanni [1 ]
Nova, Alice [1 ,4 ]
Wanderley, Hatus [1 ]
Buhl, Talisa [1 ]
Victor, Marcus [1 ,6 ]
Gaulton, Timothy G. [1 ]
La Vita, Carolyn J. [5 ]
Amato, Marcelo B. P. [7 ]
Ceradda, Maurizio [1 ]
Berra, Lorenzo [1 ]
Santiago, Roberta Ribeiro De Santis [1 ]
机构
[1] Massachusetts Gen Hosp, Harvard Med Sch, Dept Anesthesia Crit Care & Pain Med, Boston, MA 02115 USA
[2] Chulalongkorn Univ, King Chulalongkorn Mem Hosp, Fac Med, Dept Anesthesiol, Bangkok, Thailand
[3] Univ Cattolica Sacro Cuore, Dept Anesthesiol & Intens Care Med, Rome, Italy
[4] Univ Milano Bicocca, Sch Med & Surg, Milan, Italy
[5] Harvard Med Sch, Massachusetts Gen Hosp, Dept Resp Care, Boston, MA USA
[6] Aeronaut Inst Technol, Elect Engn, Sao Jose Dos Campos, Brazil
[7] Univ Sao Paulo, Hosp Clin HCFMUSP, Fac Med, Inst Coracao InCor, Sao Paulo, Brazil
来源
关键词
VENTILATION;
D O I
10.3791/66756
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Electrical Impedance Tomography (EIT) is a groundbreaking, non-invasive, and radiation-free imaging technique for continuous, real-time ventilation monitoring. It also has an application in pulmonary perfusion monitoring. EIT quantifies ventilation and perfusion patterns across the lung from the measurement and processing of impedance changes in the thorax. It is a powerful tool for clinicians to visualize breath- by-breath changes in pulmonary function. An innovative application of EIT is its ability to assess pulmonary perfusion using the kinetic analysis of a hypertonic solution injection during a breath-hold. The solution generates an impedance change in the thorax as it circulates through the pulmonary vasculature. This indirect method allows for the estimation of perfusion patterns, contributing significantly to our understanding of pulmonary blood flow dynamics at the bedside. EIT is not just a tool for monitoring but also can be critical for the diagnosis of respiratory pathologies such as pneumothorax and bronchial intubation. It can help identify the etiology of ventilation/perfusion (V/Q) mismatch in patients receiving invasive mechanical ventilation, which is not possible with other diagnostic tools. Moreover, EIT can assist in the individual optimization of ventilator settings, such as Positive End-Expiratory Pressure (PEEP) titration and tidal volume improving oxygenation and lung health in critical care. In summary, EIT represents a paradigm shift in bedside pulmonary monitoring anddiagnostics. Its non-invasive nature and immediacy of data make EIT an indispensabletool in modern respiratory medicine. With its growing applications, EIT will be pivotalin advancing our understanding of and approach to respiratory care, particularly inintensive care settings
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Prolonged Monitoring of Brain Electrical Activity in the Intensive Care Unit
    Carneiro, Thiago
    Goswami, Shweta
    Smith, Christine Nicole
    Giraldez, Maria Bruzzone
    Maciel, Carolina B.
    NEUROLOGIC CLINICS, 2025, 43 (01) : 31 - 50
  • [22] Individualized Multiplanar Electrical Impedance Tomography in Infants to Optimize Lung Monitoring
    Miedema, Martijn
    Waldmann, Andreas
    McCall, Karen E.
    Bohm, Stephan H.
    van Kaam, Anton H.
    Tingay, David G.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195 (04) : 536 - 538
  • [23] Lung Ventilation Monitoring Incorporating Prior Information by Electrical Impedance Tomography
    Chen, Xiaoyan
    Wang, Huanxiang
    Shi, Xiaolei
    Yan, Yong
    Cui, Ziqiang
    2008 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2008, : 1531 - +
  • [24] Lung monitoring with electrical impedance tomography: technical considerations and clinical applications
    Tomicic, Vinko
    Cornejo, Rodrigo
    JOURNAL OF THORACIC DISEASE, 2019, 11 (07) : 3122 - 3135
  • [25] Monitoring changes in lung air and liquid volumes with electrical impedance tomography
    Adler, A
    Amyot, R
    Guardo, R
    Bates, JHT
    Berthiaume, Y
    JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (05) : 1762 - 1767
  • [26] Wearable Lung-health Monitoring System with Electrical Impedance Tomography
    Hong, Sunjoo
    Lee, Jaehyuk
    Yoo, Hoi-Jun
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 1707 - 1710
  • [27] Monitoring of the lung fluid movement and estimation of lung area using electrical impedance tomography
    Department of Instrumentation Science, Jadavpur University, Kolkata, India
    不详
    Smart Sens. Meas. Instrum., (161-190):
  • [28] Electrical impedance tomography for pulmonary function monitoring without dorsal electrodes
    Park, Hyoungchul
    Kwon, Hyeuknam
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (01):
  • [29] Electrical impedance tomography: looking behind the secrets of regional lung function
    Calzia, E
    Hahn, G
    Hellige, G
    INTENSIVE CARE MEDICINE, 2005, 31 (11) : 1474 - 1475
  • [30] Electrical Impedance Tomography for Hemodynamic Monitoring
    Leonhardt, Steffen
    Pikkemaat, Robert
    Stenqvist, Ola
    Lundin, Stefan
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 122 - 125