Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit

被引:0
|
作者
Alcala, Glasiele C. [1 ]
Ekkapat, Gamonmas [1 ,2 ]
Medeiros, Kyle J. [1 ]
Morais, C. A. [1 ]
Xin, Yi [1 ]
Giammatte, Valentina [1 ,3 ]
Bruno, Giovanni [1 ]
Nova, Alice [1 ,4 ]
Wanderley, Hatus [1 ]
Buhl, Talisa [1 ]
Victor, Marcus [1 ,6 ]
Gaulton, Timothy G. [1 ]
La Vita, Carolyn J. [5 ]
Amato, Marcelo B. P. [7 ]
Ceradda, Maurizio [1 ]
Berra, Lorenzo [1 ]
Santiago, Roberta Ribeiro De Santis [1 ]
机构
[1] Massachusetts Gen Hosp, Harvard Med Sch, Dept Anesthesia Crit Care & Pain Med, Boston, MA 02115 USA
[2] Chulalongkorn Univ, King Chulalongkorn Mem Hosp, Fac Med, Dept Anesthesiol, Bangkok, Thailand
[3] Univ Cattolica Sacro Cuore, Dept Anesthesiol & Intens Care Med, Rome, Italy
[4] Univ Milano Bicocca, Sch Med & Surg, Milan, Italy
[5] Harvard Med Sch, Massachusetts Gen Hosp, Dept Resp Care, Boston, MA USA
[6] Aeronaut Inst Technol, Elect Engn, Sao Jose Dos Campos, Brazil
[7] Univ Sao Paulo, Hosp Clin HCFMUSP, Fac Med, Inst Coracao InCor, Sao Paulo, Brazil
来源
关键词
VENTILATION;
D O I
10.3791/66756
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Electrical Impedance Tomography (EIT) is a groundbreaking, non-invasive, and radiation-free imaging technique for continuous, real-time ventilation monitoring. It also has an application in pulmonary perfusion monitoring. EIT quantifies ventilation and perfusion patterns across the lung from the measurement and processing of impedance changes in the thorax. It is a powerful tool for clinicians to visualize breath- by-breath changes in pulmonary function. An innovative application of EIT is its ability to assess pulmonary perfusion using the kinetic analysis of a hypertonic solution injection during a breath-hold. The solution generates an impedance change in the thorax as it circulates through the pulmonary vasculature. This indirect method allows for the estimation of perfusion patterns, contributing significantly to our understanding of pulmonary blood flow dynamics at the bedside. EIT is not just a tool for monitoring but also can be critical for the diagnosis of respiratory pathologies such as pneumothorax and bronchial intubation. It can help identify the etiology of ventilation/perfusion (V/Q) mismatch in patients receiving invasive mechanical ventilation, which is not possible with other diagnostic tools. Moreover, EIT can assist in the individual optimization of ventilator settings, such as Positive End-Expiratory Pressure (PEEP) titration and tidal volume improving oxygenation and lung health in critical care. In summary, EIT represents a paradigm shift in bedside pulmonary monitoring anddiagnostics. Its non-invasive nature and immediacy of data make EIT an indispensabletool in modern respiratory medicine. With its growing applications, EIT will be pivotalin advancing our understanding of and approach to respiratory care, particularly inintensive care settings
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Electrical impedance tomography - a method for monitoring regional lung function
    Frerichs, I
    TECHNISCHES MESSEN, 2004, 71 (09): : 519 - 526
  • [2] Electrical impedance tomography in the adult intensive care unit: clinical applications and future directions
    Rubin, Jonah
    Berra, Lorenzo
    CURRENT OPINION IN CRITICAL CARE, 2022, 28 (03) : 292 - 301
  • [3] Monitoring postoperative lung recovery using electrical impedance tomography in post anesthesia care unit: an observational study
    Nadine Hochhausen
    Torsten Kapell
    Martin Dürbaum
    Andreas Follmann
    Rolf Rossaint
    Michael Czaplik
    Journal of Clinical Monitoring and Computing, 2022, 36 : 1205 - 1212
  • [4] Monitoring postoperative lung recovery using electrical impedance tomography in post anesthesia care unit: an observational study
    Hochhausen, Nadine
    Kapell, Torsten
    Duerbaum, Martin
    Follmann, Andreas
    Rossaint, Rolf
    Czaplik, Michael
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (04) : 1205 - 1212
  • [5] Expert opinion document: "Electrical impedance tomography: applications from the intensive care unit and beyond"
    Rauseo, Michela
    Spinelli, Elena
    Sella, Nicolo
    Slobod, Douglas
    Spadaro, Savino
    Longhini, Federico
    Giarratano, Antonino
    Gilda, Cinnella
    Mauri, Tommaso
    Navalesi, Paolo
    JOURNAL OF ANESTHESIA ANALGESIA AND CRITICAL CARE, 2022, 2 (01):
  • [6] Patient examinations using electrical impedance tomography-sources of interference in the intensive care unit
    Frerichs, Inez
    Pulletz, Sven
    Elke, Gunnar
    Gawelczyk, Barbara
    Frerichs, Alexander
    Weiler, Norbert
    PHYSIOLOGICAL MEASUREMENT, 2011, 32 (12) : L1 - L10
  • [7] Electrical impedance tomography in monitoring experimental lung injury
    I. Frerichs
    G. Hahn
    T. Schröder
    G. Heilige
    Intensive Care Medicine, 1998, 24 : 829 - 836
  • [8] Electrical impedance tomography for lung ventilation monitoring of the dog
    Gloning, Simon
    Pieper, Korbinian
    Zoeliner, Martin
    Meyer-Lindenberg, Andrea
    TIERAERZTLICHE PRAXIS AUSGABE KLEINTIERE HEIMTIERE, 2017, 45 (01): : 15 - 21
  • [9] The Research Progress of Electrical Impedance Tomography for Lung Monitoring
    Shi, Yan
    Yang, ZhiGuo
    Xie, Fei
    Ren, Shuai
    Xu, ShaoFeng
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [10] Monitoring of lung volume in dogs with electrical impedance tomography
    Adler, A
    Shinozuka, N
    Guardo, R
    Berthiaume, Y
    Bates, J
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 776 - 777