Comparison of femoral bone remodeling after total hip arthroplasty with cementless short-tapered wedge stem and fully hydroxyapatite-coated stem

被引:0
作者
Naito, Yohei [1 ]
Hasegawa, Masahiro [1 ]
Tone, Shine [1 ]
Wakabayashi, Hiroki [1 ]
Sudo, Akihiro [1 ]
机构
[1] Mie Univ, Grad Sch Med, Dept Orthoped Surg, 2-174 Edobashi, Tsu, Mie 5148507, Japan
关键词
Total hip arthroplasty; Bone mineral density; Shot-tapered wedge stem; Fully hydroxyapatite-coated stem; FIXATION; TITANIUM; OUTCOMES;
D O I
10.1007/s00402-024-05484-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionWe aimed to compare periprosthetic femoral bone remodeling after cementless total hip arthroplasty (THA) using a short-tapered wedge stem and a fully hydroxyapatite (HA)-coated stem.Materials and methodsIn this retrospective study, 24 primary cementless THA procedures with short-tapered wedge stem and 24 using a fully HA-coated stem were performed. The follow-up duration was 2 years for both groups. Clinical evaluation was performed using the Merle d'Aubign & eacute; and Postel scoring systems. Standardized anteroposterior radiographs of the pelvis and femur were obtained. Dual-energy X-ray absorptiometry was performed, and the bone mineral density (BMD) around the stem was assessed in each Gruen zone at the first postoperative week as a baseline value and at 6 weeks, 3 and 6 months, and 1 and 2 years postoperatively.ResultsThe mean Merle d'Aubign & eacute; and Postel scores improved significantly postoperatively in both groups. None of the hips showed loosening in either group. Spot welds occurred in zones 1, 2, 6, and 7 in the short-tapered wedge group, and in all zones in the fully HA-coated group. Significant BMD loss occurred only in zone 4 in the short-tapered wedge group, and no significant bone loss occurred in any zone in the fully HA-coated stem group; a significant difference between the two groups was observed only in zone 4 at 2 years after THA.ConclusionsClinical and radiographical outcomes in both groups were good, and both stems suppressed postoperative BMD loss at 2 years.
引用
收藏
页码:3767 / 3774
页数:8
相关论文
共 33 条
  • [1] Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), Annual Report
  • [2] The Short and "Shorter" of It: >1750 Tapered Titanium Stems at 6-to 88-Month Follow-Up
    Barrington, John W.
    Emerson, Roger H., Jr.
    [J]. JOURNAL OF ARTHROPLASTY, 2013, 28 (08) : 38 - 40
  • [3] Bone Remodeling Characteristics of a Short-Stemmed Total Hip Replacement
    Chen, Hsiang-Ho
    Morrey, Bernard F.
    An, Kai-Nan
    Luo, Zong-Ping
    [J]. JOURNAL OF ARTHROPLASTY, 2009, 24 (06) : 945 - 950
  • [4] Modeling of bone around hydroxyapatite-coated femoral stems
    DAntonio, JA
    Township, M
    Capello, WN
    Manley, MT
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (08) : 1226 - 1234
  • [5] FUNCTIONAL RESULTS OF HIP ARTHROPLASTY WITH ACRYLIC PROSTHESIS
    DAUBIGNE, RM
    POSTEL, M
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1954, 36-A (03) : 451 - 475
  • [6] STRUCTURAL AND CELLULAR ASSESSMENT OF BONE QUALITY OF PROXIMAL FEMUR
    DORR, LD
    FAUGERE, MC
    MACKEL, AM
    GRUEN, TA
    BOGNAR, B
    MALLUCHE, HH
    [J]. BONE, 1993, 14 (03) : 231 - 242
  • [7] ENGH CA, 1990, CLIN ORTHOP RELAT R, P107
  • [8] CEMENTLESS ACETABULAR COMPONENTS
    ENGH, CA
    GRIFFIN, WL
    MARX, CL
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (01): : 53 - 59
  • [9] 7-year results of primary total hip arthroplasty with the uncemented Avenir stem
    Erivan, Roger
    Villatte, Guillaume
    Brientini, Jean-Michel
    Kreider, David
    Descamps, Stephane
    Boisgard, Stephane
    [J]. HIP INTERNATIONAL, 2019, 29 (04) : 418 - 423
  • [10] Minimum 10-year results of a tapered, titanium, hydroxyapatite-coated hip stem
    Froimson, Mark I.
    Garino, Jonathan
    Machenaud, Alan
    Vidalain, J. P.
    [J]. JOURNAL OF ARTHROPLASTY, 2007, 22 (01) : 1 - 7