Thermal performance research on the zero liquid helium consumption cryostat for a superconducting undulator

被引:0
|
作者
Zhang, Xiangzhen [1 ,2 ]
Xu, Miaofu [1 ,3 ]
Chen, Zilin [1 ]
Yang, Xiaochen [1 ]
Yang, Xiangchen [1 ,3 ]
Zhao, Tongxian [1 ]
Ye, Rui [1 ]
Bian, Xiaojuan [1 ]
Gao, Yao [1 ]
Han, Ruixiong [1 ]
Sun, Liangrui [1 ]
Lu, Huihua [1 ]
Li, Yuhui [1 ,2 ]
Ge, Rui [1 ,2 ]
Zhu, Zian [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Univ Sci & Technol China, Hefei 230026, Peoples R China
基金
中国国家自然科学基金;
关键词
Thermal analysis; Zero liquid helium consumption; Boil-off gas liquefaction; Excess cooling capacity; Superconducting magnet; MULTILAYER INSULATION; WIGGLER; MAGNET;
D O I
10.1016/j.energy.2024.132868
中图分类号
O414.1 [热力学];
学科分类号
摘要
Superconducting undulators generally depend on a liquid helium cryostat. If the cryostat can liquefy the boil-off helium completely, a large helium refrigerator can be avoided, and a large amount of electrical energy can be saved. However, many studies are limited by the excessively high heat load. In this work, systematic thermal analysis and optimization are carried out to minimize the total heat load so that it can be covered by the cooling capacity. Based on the analysis, one single thermal shield is set in the cryostat, and thermal interruptions are widely adopted together. Moreover, the cooling capacity matches the heat load well, and the excess cooling capacity is increased significantly. In the experiment, the cryostat was tested with no magnet, a small magnet and a full-scale magnet respectively so that the heat load could be analyzed step by step. Finally, zero liquid helium consumption was achieved with the full-scale superconducting magnet, which reached a current of 450 A. The excess cooling capacity accounts for approximately 40 % of the total cooling capacity, which is as high as approximately 2.0 W. This study can serve as a reference for the research of superconducting undulator and other magnet cryostats.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Development of liquid helium-free cryostat for a superconducting undulator
    Zhang, Xiangzhen
    Xu, Miaofu
    Yang, Xiangchen
    Bian, Xiaojuan
    Chen, Zilin
    Wei, Junhao
    Sun, Liangrui
    Yang, Xiaochen
    Lu, Huihua
    Ge, Rui
    Zhu, Zian
    Li, Yuhui
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1049
  • [2] A novel scheme of the zero-liquid-helium-consumption cryostat for superconducting wigglers
    Zhang, Xiangzhen
    Xu, Miaofu
    Ye, Rui
    Bian, Lin
    Yang, Xiaochen
    Sun, Liangrui
    Han, Ruixiong
    Lu, Huihua
    Chen, Fusan
    Zhu, Zian
    Ge, Rui
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1057
  • [3] Thermal Analysis of a Helical Superconducting Undulator Cryostat
    Shiroyanagi, Yuko
    Fuerst, Joel
    Hasse, Quentin
    Kasa, Matthew
    Kesgin, Ibrahim
    Ivanyushenkov, Yury
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2019, 29 (05)
  • [4] Thermal Analysis of a Superconducting Undulator Cryostat for the APS Upgrade
    Shiroyanagi, Y.
    Anliker, E.
    Hasse, Q.
    Ivanyushenkov, Y.
    Kasa, M.
    Fuerst, J.
    ADVANCES IN CRYOGENIC ENGINEERING, 2020, 755
  • [5] Novel correction procedure for compensating thermal contraction errors in the measurement of the magnetic field of superconducting undulator coils in a liquid helium cryostat
    Marchetti, Barbara
    Baader, Johann
    Casalbuoni, Sara
    Yakopov, Grigory
    Yakopov, Mikhail
    JOURNAL OF SYNCHROTRON RADIATION, 2024, 31 (Pt 2) : 282 - 294
  • [6] Thermal performance of the XRS helium cryostat
    Breon, SR
    DiPirro, MJ
    Warner, BA
    Shirron, PJ
    Tuttle, JG
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 43 PTS A AND B, 1998, 43 : 941 - 948
  • [7] Development of a zero boil-off helium cryostat for superconducting magnets
    Wang, Meifen
    Yang, Huan
    Ning, Feipeng
    Zhu, Zian
    26TH INTERNATIONAL CONFERENCE ON LOW TEMPERATURE PHYSICS (LT26), PTS 1-5, 2012, 400
  • [8] LEAK CHECKING A SUPERCONDUCTING CYCLOTRON CRYOSTAT WITH LIQUID-HELIUM
    LAUMER, HW
    MALLORY, ML
    POE, DR
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1981, 26 (01): : 46 - 46
  • [9] CONSTRUCTION DETAILS OF A LIQUID-HELIUM CRYOSTAT FOR A SUPERCONDUCTING OBJECTIVE AND COLD STAGE
    LAMVIK, MK
    WORSHAM, RE
    KOPF, DA
    ROBERTSON, JD
    ULTRAMICROSCOPY, 1984, 12 (1-2) : 79 - 82
  • [10] Design and performance of a miniature cryostat for emission measurements in liquid helium
    Jasny, Jan
    Slenczka, Alkwin
    Dick, Bernhard
    Zeitschrift fur Physikalische Chemie, 2001, 215 (12): : 1565 - 1573