An enhanced SPR optical fiber biosensor using Ti3C2Tx MXene/AuNPs for label-free and sensitive detection of human IgG

被引:3
作者
Zhu, Jiayi [1 ]
Zhao, Chao [1 ]
Xia, Binyun [1 ]
Wang, Ning [1 ]
Chen, Xi [2 ]
Jing, Xinyue [1 ]
Chen, Minxuan [1 ]
Xu, Xinrui [1 ]
机构
[1] Natl Engn Res Ctr Fiber Opt Sensing Technol & Netw, Wuhan 430070, Peoples R China
[2] Wuhan Univ, Dept Orthoped Trauma & Microsurg, Zhongnan Hosp, Wuhan 430071, Hubei, Peoples R China
基金
中国国家自然科学基金;
关键词
PLASMON RESONANCE BIOSENSOR; SENSOR; NANOPARTICLES; SIZE;
D O I
10.1039/d4nr01883d
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Abnormal human immunoglobulin G (IgG) may induce the risk of immune system disorder, infectious diseases, tumors and so on. However, the current detection methods exhibit low sensitivity, which limits their practical application. In this work, an SPR optical fiber sensor (SPR-OFS) with high sensitivity is designed for label-free detection of human IgG. It is fabricated using a heterostructure optical fiber coated with Au film/AuNPs and the Ti3C2Tx MXene biofunctionalized with goat anti-human IgG by polydopamine (PDA). In the experiment, the optimal thickness of the Ti3C2Tx MXene was explored and determined to be about 93 nm by comprehensively considering the refractive index (RI) sensitivity and spectral bandwidth of the SPR sensor. When the largest figure of merit (FOM) is calculated to be 17.8279 RIU-1, its RI sensitivity was ultimately found to be 2804.5 nm per RIU. The SPR-OFS was employed to detect human IgG within the concentration range of 0-30 mu g mL-1 and its sensitivity is demonstrated to be 1.7046 nm (mu g mL-1)-1. The SPR-OFS was also proved to have excellent linearity, specificity and stability. The proposed sensor offers outstanding performance with simple fabrication, providing a cutting-edge bioanalytical platform with potential applications in clinical diagnosis.
引用
收藏
页码:18477 / 18487
页数:11
相关论文
共 67 条
  • [1] Point-of-care diagnosis of pre-eclampsia based on microfiber Bragg grating biosensor
    Cao, Shifang
    Chen, Ruiping
    Yang, Qiaochu
    He, Xin
    Chiavaioli, Francesco
    Ran, Yang
    Guan, Bai-Ou
    [J]. BIOSENSORS & BIOELECTRONICS, 2024, 249
  • [2] D-type optical fiber immunoglobulin G sensor based on surface plasmon resonance
    Chen, Mengdan
    Lang, Tingting
    Cao, Bobo
    Yu, Yuzhen
    Shen, Changyu
    [J]. OPTICS AND LASER TECHNOLOGY, 2020, 131 (131)
  • [3] Refractive Index Sensors Based on Ti3C2Tx MXene Fibers
    Chen, Yuzhi
    Ge, Yanqi
    Huang, Weichun
    Li, Zhongjun
    Wu, Leiming
    Zhang, Han
    Li, Xuejin
    [J]. ACS APPLIED NANO MATERIALS, 2020, 3 (01) : 303 - 311
  • [4] Femtomolar Detection by Nanocoated Fiber Label-Free Biosensors
    Chiavaioli, Francesco
    Zubiate, Pablo
    Del Villar, Ignacio
    Zamarreno, Carlos R.
    Giannetti, Ambra
    Tombelli, Sara
    Trono, Cosimo
    Arregui, Francisco J.
    Matias, Ignacio R.
    Baldini, Francesco
    [J]. ACS SENSORS, 2018, 3 (05): : 936 - 943
  • [5] Towards a Uniform Metrological Assessment of Grating-Based Optical Fiber Sensors: From Refractometers to Biosensors
    Chiavaioli, Francesco
    Gouveia, Carlos A. J.
    Jorge, Pedro A. S.
    Baldini, Francesco
    [J]. BIOSENSORS-BASEL, 2017, 7 (02):
  • [6] Sol-Gel-Based Titania-Silica Thin Film Overlay for Long Period Fiber Grating-Based Biosensors
    Chiavaioli, Francesco
    Biswas, Palas
    Trono, Cosimo
    Jana, Sunirmal
    Bandyopadhyay, Somnath
    Basumallick, Nandini
    Giannetti, Ambra
    Tombelli, Sara
    Bera, Susanta
    Mallick, Aparajita
    Baldini, Francesco
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (24) : 12024 - 12031
  • [7] Surface Plasmon Resonance Refractive Index Sensor Based on Tapered Coreless Optical Fiber Structure
    Ding, Zhe-Wen
    Lang, Ting-Ting
    Wang, Yu
    Zhao, Chun-Liu
    [J]. JOURNAL OF LIGHTWAVE TECHNOLOGY, 2017, 35 (21) : 4734 - 4739
  • [8] Are LOD and LOQ Reliable Parameters for Sensitivity Evaluation of Spectroscopic Methods?
    Ershadi, Saba
    Shayanfar, Ali
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2018, 101 (04) : 1212 - 1213
  • [9] Determination of size and concentration of gold nanoparticles from UV-Vis spectra
    Haiss, Wolfgang
    Thanh, Nguyen T. K.
    Aveyard, Jenny
    Fernig, David G.
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (11) : 4215 - 4221
  • [10] Compact Surface Plasmon Resonance IgG Sensor Based on H-Shaped Optical Fiber
    Huang, Yijian
    Wang, Ying
    Xu, Gaixia
    Rao, Xing
    Zhang, Jiaxiong
    Wu, Xun
    Liao, Changrui
    Wang, Yiping
    [J]. BIOSENSORS-BASEL, 2022, 12 (03):