Rare Central Venous Catheter Malpositions: A Case Series

被引:0
作者
Tanyildizi, Busra [1 ]
机构
[1] Kastamonu Educ & Res Hosp, Anesthesiol & Reanimat, Kastamonu, Turkiye
关键词
central venous catheter; chest x ray; ultrasound-guided; intensive care; malposition; COMPLICATIONS; INSERTION;
D O I
10.7759/cureus.63872
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Central venous catheters are a procedure that provides vascular access, allowing the application of various clinical treatments and the measurement of some hemodynamic values. It provides access to the internal jugular vein, subclavian vein, and, femoral vein with a large-bore catheter. There are mechanical, infectious, and thromboembolic complications resulting from central venous catheter placement and care. Central venous catheter malposition is a rare catheter complication that may be encountered. The location of the central venous catheter can be evaluated with imaging techniques such as posteroanterior chest radiograph, ultrasonography, central venous catheter waveform, and transesophageal echocardiography. Five malposition cases detected by imaging after the central venous catheter procedure in our clinic are presented.
引用
收藏
页数:9
相关论文
共 22 条
[1]  
Agrawal Sanjay, 2012, J Emerg Trauma Shock, V5, P304, DOI 10.4103/0974-2700.102369
[2]  
Alemohammad M, 2013, TEHRAN U MED J, V70, P8
[3]   Guidewire localization by transthoracic echocardiography during central venous catheter insertion: a periprocedural method to evaluate catheter placement [J].
Bedel, Jerome ;
Vallee, Fabrice ;
Mari, Arnaud ;
Riu, Beatrice ;
Planquette, Benjamin ;
Geeraerts, Thomas ;
Genestal, Michele ;
Minville, Vincent ;
Fourcade, Olivier .
INTENSIVE CARE MEDICINE, 2013, 39 (11) :1932-1937
[4]   Supradiaphragmatic central venous catheter malposition detection using the parasternal long-axis echocardiographic view and dextrose 50% contrast solution: A pilot study [J].
Che Rahim, Mohd Jazman ;
Abdull Wahab, Shaik Farid ;
Fauzi, Mohd Hashairi ;
Nadarajan, Chandran ;
Ab Hamid, Siti Azrin .
ULTRASOUND, 2022, 30 (04) :292-298
[5]   Using central venous pressure waveform to confirm the placement of an internal jugular central venous catheter in the intensive care unit [J].
Chua, Charlene Kit Zhen ;
Le Guen, Maurice ;
Lim, Richard ;
Udy, Andrew .
AUSTRALIAN CRITICAL CARE, 2024, 37 (04) :628-631
[6]   Should we measure the central venous pressure to guide fluid management? Ten answers to 10 questions [J].
De Backer, Daniel ;
Vincent, Jean-Louis .
CRITICAL CARE, 2018, 22
[7]   Comparison between ultrasound and chest X-ray to confirm central venous catheter tip position [J].
de Man, Leoni ;
Wentzel, Mari ;
van Rooyen, Cornel ;
Turton, Edwin .
SA JOURNAL OF RADIOLOGY, 2023, 27 (01)
[8]  
Eisen Lewis A, 2006, J Intensive Care Med, V21, P40, DOI 10.1177/0885066605280884
[9]   Routine Chest Radiography Is Not Necessary After Ultrasound-Guided Right Internal Jugular Vein Catheterization [J].
Hourmozdi, Justin J. ;
Markin, Abraham ;
Johnson, Brad ;
Fleming, Patrick R. ;
Miller, Joseph B. .
CRITICAL CARE MEDICINE, 2016, 44 (09) :E804-E808
[10]   Determination of optimal tip position of peripherally inserted central catheters using electrocardiography: a retrospective study [J].
Jung, Ki Tae ;
Kelly, Linda ;
Kuznetsov, Alexandra ;
Sabouri, A. Sassan ;
Lee, Kichang .
KOREAN JOURNAL OF ANESTHESIOLOGY, 2023, 76 (03) :242-251