New findings on clinical experience on surface-guided radiotherapy for frameless non-coplanar stereotactic radiosurgery treatments

被引:0
作者
Sanchez-Rubio, Patricia [1 ]
Rodriguez-Romero, Ruth [1 ]
Pinto-Monedero, Maria [1 ]
Alejo-Luque, Luis [1 ]
Martinez-Ortega, Jaime [1 ]
机构
[1] Hosp Univ Puerta de Hierro Majadahonda, Med Phys Dept, Madrid, Spain
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2024年 / 25卷 / 12期
关键词
AlignRT; frameless non-coplanar SRS; intrafraction control; open-face mask; SGRT; RADIATION-THERAPY; OPEN-FACE; ISOCENTER; BEAM; ACCURACY; IMPACT; MOTION; MASKS; HEAD;
D O I
10.1002/acm2.14510
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to assess the accuracy of a surface-guided radiotherapy (SGRT) system for setup and intra-fraction motion control in frameless non-coplanar stereotactic radiosurgery (fSRS) using actual patient data immobilized with two different types of open-faced masks and employing a novel SGRT systems settings. Methods and materials: Forty-four SRS patients were immobilized with two types of open-faced masks. Sixty lesions were treated, involving the analysis of 68 cone-beam scans (CBCT), 157 megavoltage (MV) images, and 521 SGRT monitoring sessions. The average SGRT translations/rotations and 3D vectors (MAG-Trasl and MAG-Rot) were compared with CBCT or antero-posterior MV images for 0 degrees table or non-coplanar beams, respectively. The intrafraction control was evaluated based on the average shifts obtained from each monitoring session. To assess the association between the SGRT system and the CBCT, the two types of masks and the 3D vectors, a generalized estimating equations (GEE) regression analysis was performed. The Wilcoxon singed-rank test for paired samples was performed to detect differences in couch rotation with longitudinal (LNG) and lateral (LAT) translations and/or yaw. Results: The average SGRT corrections were smaller than those detected by CBCT (<= 0.5 mm and 0.1 degrees), with largest differences in LNG and yaw. The GEE analysis indicated that the average MAG-Trasl, obtained by the SGRT system, was not statistically different (p = 0.09) for both mask types, while, the MAG-Rot was different (p = 0.01). For non-coplanar beams, the Wilcoxon singed-rank test demonstrated no significantly differences for the corrections (LNG, LAT, and yaw) for any table rotation except for LNG corrections at 65 degrees (p = 0.04) and 75 degrees (p = 0.03) table angle position; LAT shifts at 65 degrees (p = 0.03) and 270 degrees (p < 0.001) table angle position, and yaw rotation at 30 degrees (p = 0.02) table angle position. The average intrafraction motion was < 0.1 mm and 0.1 degrees for any table angle. Conclusion: The SGRT system used, along with the novel workflow performed, can achieve the setup and intra-fraction motion control accuracy required to perform non-coplanar fSRS treatments. Both masks ensure the accuracy required for fSRS while providing a suitable surface for monitoring.
引用
收藏
页数:13
相关论文
共 54 条
  • [1] The role of surface-guided radiation therapy for improving patient safety
    Al-Hallaq, Hania
    Batista, Vania
    Kugele, Malin
    Ford, Eric
    Viscariello, Natalie
    Meyer, Juergen
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 163 : 229 - 236
  • [2] AAPM task group report 302: Surface-guided radiotherapy
    Al-Hallaq, Hania A.
    Cervino, Laura
    Gutierrez, Alonso N.
    Havnen-Smith, Amanda
    Higgins, Susan A.
    Kugele, Malin
    Padilla, Laura
    Pawlicki, Todd
    Remmes, Nicholas
    Smith, Koren
    Tang, Xiaoli
    Tome, Wolfgang A.
    [J]. MEDICAL PHYSICS, 2022, 49 (04) : E82 - E112
  • [3] Alexander D A., 2021, Retrospective Evaluation of an Always-on Cherenkov Imaging System for Radiotherapy Quality Improvement
  • [4] Surface guided radiation therapy: An international survey on current clinical practice
    Batista, V.
    Gober, M.
    Moura, F.
    Webster, A.
    Oellers, M.
    Ramtohul, M.
    Kuegele, M.
    Freislederer, P.
    Buschmann, M.
    Anastasi, G.
    Steiner, E.
    Al-Hallaq, H.
    Lehmann, J.
    [J]. TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2022, 22 : 1 - 8
  • [5] Clinical paradigms and challenges in surface guided radiation therapy: Where do we go from here?
    Batista, Vania
    Meyer, Juergen
    Kugele, Malin
    Al-Hallaq, Hania
    [J]. RADIOTHERAPY AND ONCOLOGY, 2020, 153 : 34 - 42
  • [6] Precision of image-guided spinal stereotactic ablative radiotherapy and impact of positioning variables
    Billiet, Charlotte
    Vingerhoed, Wim
    Van Laere, Steven
    Joye, Ines
    Mercier, Carole
    Dirix, Piet
    Nevens, Daan
    Vermeulen, Peter
    Meijnders, Paul
    Verellen, Dirk
    [J]. PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 22 : 73 - 76
  • [7] Online Combination of EPID & Cherenkov Imaging for 3-D Dosimetry in a Liquid Phantom
    Bruza, Petr
    Andreozzi, Jacqueline M.
    Gladstone, David J.
    Jarvis, Lesley A.
    Rottmann, Joerg
    Pogue, Brian W.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (10) : 2099 - 2103
  • [8] End to end comparison of surface-guided imaging versus stereoscopic X-rays for the SRS treatment of multiple metastases with a single isocenter using 3D anthropomorphic gel phantoms
    Bry, Victoria
    Saenz, Daniel
    Pappas, Evangelos
    Kalaitzakis, Georgios
    Papanikolaou, Nikos
    Rasmussen, Karl
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (05):
  • [9] Covington EL, 2024, J APPL CLIN MED PHYS, V25, DOI [10.1002/acm2.14444, 10.1002/acm2.14058]
  • [10] Surface guided imaging during stereotactic radiosurgery with automated delivery
    Covington, Elizabeth L.
    Stanley, Dennis N.
    Fiveash, John B.
    Thomas, Evan M.
    Marcrom, Samuel R.
    Bredel, Marcus
    Willey, Christopher D.
    Riley, Kristen O.
    Popple, Richard A.