SILICONE FINE-NEEDLE ASPIRATION RETINAL BIOPSY

被引:0
作者
Petrovic, Mojca Globocnik [1 ,2 ,5 ]
Vrabic, Nika [1 ]
Kloboves, Veronika Prevodnik [3 ,4 ]
Miceska, Simona [3 ]
Rosar, Ana Pajtler [1 ]
Valentincic, Natasa Vidovic [1 ,2 ]
机构
[1] Univ Med Ctr Ljubljana, Eye Hosp, Ljubljana, Slovenia
[2] Univ Ljubljana, Fac Med, Ljubljana, Slovenia
[3] Inst Oncol Ljubljana, Dept Cytopathol, Ljubljana, Slovenia
[4] Univ Maribor, Fac Med, Maribor, Slovenia
[5] UMC Ljubljana, Eye Clin, Grabloviceva Ulic 46, Ljubljana 1000, Slovenia
来源
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES | 2024年 / 44卷 / 09期
关键词
primary vitreoretinal lymphoma; 41-gauge silicone fine-needle retinal biopsy; vitrectomy; cytology; case series; CHOROIDAL BIOPSIES; LYMPHOMA; DIAGNOSIS; TUMORS;
D O I
10.1097/IAE.0000000000004161
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
A 41-gauge silicone fine-needle aspirational biopsy is valuable for obtaining high-quality retinal and subretinal samples when primary intraocular lymphoma is suspected. The technique provides high-quality samples for cytologic analysis. Purpose:To describe a 41-gauge silicone fine-needle aspiration biopsy (S-FNAB) technique and assess its value in diagnosing primary vitreoretinal lymphoma (PVRL).Methods:Retrospective review of seven consecutive patients who underwent vitreous biopsy (VB) and 41-gauge S-FNAB of retinal/subretinal lesions in a single tertiary center between January 2012 and March 2023.Results:Of seven patients, S-FNAB confirmed the diagnosis of PVRL in six patients. In five of those patients, both VB and retinal/subretinal S-FNAB (performed at the same procedure) yielded positive results, with the retinal thickness at the biopsy site as small as 231 mu m. Four of these five patients had one or more previous negative VB. In one patient, S-FNAB yielded positive results despite a negative VB. Silicone fine-needle aspiration biopsy failed to confirm positive VB for PVRL in the remaining patient. The time from symptom onset to diagnosis of PVRL ranged from 18 days to 26 months. There were no severe complications associated with the procedure.Conclusion:Silicone fine-needle aspiration biopsy might be a valuable method for obtaining a sufficient sample of viable cells to diagnose PVRL. It can be performed as a primary procedure along with VB. Further studies are warranted to determine where this technique could be most advantageous.
引用
收藏
页码:1590 / 1596
页数:7
相关论文
共 20 条
  • [1] Intraocular biopsy using special forceps: a new instrument and refined surgical technique
    Akgul, Harun
    Otterbach, Friedrich
    Bornfeld, Norbert
    Jurklies, Bernhard
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (01) : 79 - 82
  • [2] The 5th edition of the World Health Organization Classification of Haematolymphoid Tumours: Lymphoid Neoplasms
    Alaggio, Rita
    Amador, Catalina
    Anagnostopoulos, Ioannis
    Attygalle, Ayoma D.
    Araujo, Iguaracyra Barreto de Oliveira
    Berti, Emilio
    Bhagat, Govind
    Borges, Anita Maria
    Boyer, Daniel
    Calaminici, Mariarita
    Chadburn, Amy
    Chan, John K. C.
    Cheuk, Wah
    Chng, Wee-Joo
    Choi, John K.
    Chuang, Shih-Sung
    Coupland, Sarah E.
    Czader, Magdalena
    Dave, Sandeep S.
    de Jong, Daphne
    Du, Ming-Qing
    Elenitoba-Johnson, Kojo S.
    Ferry, Judith
    Geyer, Julia
    Gratzinger, Dita
    Guitart, Joan
    Gujral, Sumeet
    Harris, Marian
    Harrison, Christine J.
    Hartmann, Sylvia
    Hochhaus, Andreas
    Jansen, Patty M.
    Karube, Kennosuke
    Kempf, Werner
    Khoury, Joseph
    Kimura, Hiroshi
    Klapper, Wolfram
    Kovach, Alexandra E.
    Kumar, Shaji
    Lazar, Alexander J.
    Lazzi, Stefano
    Leoncini, Lorenzo
    Leung, Nelson
    Leventaki, Vasiliki
    Li, Xiao-Qiu
    Lim, Megan S.
    Liu, Wei-Ping
    Louissaint, Abner, Jr.
    Marcogliese, Andrea
    Medeiros, L. Jeffrey
    [J]. LEUKEMIA, 2022, 36 (07) : 1720 - 1748
  • [3] A new technique of combined retinal and choroidal biopsy
    Cole, C. J.
    Kwan, A. S.
    Laidlaw, D. A. H.
    Aylward, G. W.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2008, 92 (10) : 1357 - 1360
  • [4] Surgical Removal of Submacular Perfluorocarbon Liquid Using a 41-Gauge Extendible Subretinal Injection Needle
    Falavarjani, Khalil Ghasemi
    Anvari, Pasha
    [J]. JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2019, 14 (03) : 393 - 397
  • [5] Intravitreal methotrexate for treating vitreoretinal lymphoma: 10 years of experience
    Frenkel, S.
    Hendler, K.
    Siegal, T.
    Shalom, E.
    Pe'er, J.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2008, 92 (03) : 383 - 388
  • [6] Lymphoma presenting as a solitary mass: Diagnosis by fine needle aspiration biopsy
    Fyrat, P
    Mocan, G
    [J]. CYTOPATHOLOGY, 2000, 11 (04) : 276 - 278
  • [7] Ocular presentation of primary central nervous system lymphoma: diagnosis and treatment
    Hormigo, A
    Abrey, L
    Heinemann, MH
    DeAngelis, LM
    [J]. BRITISH JOURNAL OF HAEMATOLOGY, 2004, 126 (02) : 202 - 208
  • [8] Standardization of uveitis nomenclature for reporting clinical data. Results of the First International Workshop
    Jabs, DA
    Nussenblatt, RB
    Rosenbaum, JT
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (03) : 509 - 516
  • [9] Choroidal biopsies for Intraocular tumors of indeterminate origin
    Kvanta, A
    Seregard, S
    Kopp, ED
    All-Ericsson, C
    Landau, I
    Berglin, L
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (06) : 1002 - 1006
  • [10] 41 Gauge Transvitreal Fine-Needle Aspiration Biopsy for Intraocular Tumors Without Vitrectomy
    Lee, Chul Hee
    Shin, Su-Jin
    Kim, Min