Influence of Crown Height and Width on Marginal Bone Loss and Long-Term Stability of Dental Implants: A Systematic Review

被引:1
作者
Jain, Ritul [1 ]
Pisulkar, Sweta G. [1 ]
Dubey, Surekha A. [1 ]
Bansod, Akansha [1 ]
Beri, Arushi [1 ]
Deshmukh, Shruti [1 ]
机构
[1] Datta Meghe Inst Higher Educ & Res, Sharad Pawar Dent Coll & Hosp, Dept Prosthodont & Crown & Bridge, Wardha, India
关键词
bone density; short implants; implant stability; crown-implant ratio; dental implants; marginal bone loss; crown width; crown height; RESONANCE FREQUENCY-ANALYSIS; COMPLICATION RATES; INSERTION TORQUE; SURVIVAL; RATIO;
D O I
10.7759/cureus.65109
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Still, a major focus of research in implantology is how crown height and width affect marginal bone loss (MBL) and the long-term durability of dental implants. Maximizing the success of implants and lowering problems depends on an awareness of these elements. Following the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines, this systematic review searched pertinent studies across several databases using keywords unique to databases. Studies on MBL and long-term implant stability evaluated in the review included those on crown height and width, horizontal and vertical cantilevers, and prosthesis dimensions. In the chosen studies, we found that both implant success and crestal bone loss were greatly influenced by crown height and width. Particularly in the posterior sections, horizontal cantilevers were connected to both increasing MBL and mechanical problems. Vertical cantilevers also affected MBL; however, their impacts were more obvious in circumstances with greater crown heights. Greater prosthesis widths, especially in the mandibular molar area, were linked to higher MBL. Bone density and insertion torque (IT) were the main determinants of MBL, more than the primary implant stability quotient. Early MBL was influenced by abutment height, mucosal thickness, and implant insertion depth; bone levels stabilized six months later. Short implants allow single crowns to be supported, but in some cases, a higher failure rate was seen. The success and stability of dental implants were found to be mostly dependent on crown height, width, and cantilever design. MBL and long-term stability are greatly influenced by horizontal and vertical cantilevers, which calls for careful design and planning. With specific care for bone density, IT, and early MBL stabilization, both short and standard implants can produce equivalent results. These results highlight the need for customized treatment plans to maximize implant success and lifetime.
引用
收藏
页数:9
相关论文
共 40 条
[1]   Does the Length of Mini Dental Implants Affect Their Resistance to Failure by Overloading? [J].
Alshenaiber, Rafif ;
Silikas, Nick ;
Barclay, Craig .
DENTISTRY JOURNAL, 2022, 10 (07)
[2]   Implant Survival and Crestal Bone Loss Around Extra-Short Implants Supporting a Fixed Denture: The Effect of Crown Height Space, Crown-to-Implant Ratio, and Offset Placement of the Prosthesis [J].
Anitua, Eduardo ;
Hamdan Alkhraist, Mohammad ;
Pinas, Laura ;
Begona, Leire ;
Orive, Gorka .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (03) :682-689
[3]   Outcomes of treatment with short dental implants compared with standard-length implants: a retrospective clinical study [J].
Berczy, Kinga ;
Gondoecs, Gyorgy ;
Komlos, Gyorgy ;
Shkolnik, Tatiana ;
Szabo, Gyorgy ;
Nemeth, Zsolt .
MAXILLOFACIAL PLASTIC AND RECONSTRUCTIVE SURGERY, 2024, 46 (01)
[4]   Relationship Between Insertion Torque and Resonance Frequency Measurements, Performed by Resonance Frequency Analysis, in Micromobility of Dental Implants: An In Vitro Study [J].
Brizuela-Velasco, Aritza ;
Alvarez-Arenal, Angel ;
Javier Gil-Mur, Francisco ;
Herrero-Climent, Mariano ;
Chavarri-Prado, David ;
Chento-Valiente, Yelko ;
Dieguez-Pereira, Markel .
IMPLANT DENTISTRY, 2015, 24 (05) :607-611
[5]  
Brunski JB, 2000, INT J ORAL MAX IMPL, V15, P15
[6]   Are the Insertion Torque Value and Implant Stability Quotient Correlated, and If So, Can Insertion Torque Values Predict Secondary Implant Stability? A Prospective Parallel Cohort Study [J].
Cassetta, Michele ;
Brandetti, Giulia ;
Altieri, Federica .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (01) :135-142
[7]  
Di Fiore A, 2020, Front Oral Maxillofac Med, V2, P2, DOI [10.21037/fomm-20-57, DOI 10.21037/FOMM-20-57]
[8]   Influence of Crown-to-Implant Ratio on Long Term Marginal Bone Loss Around Short Implants [J].
Di Fiore, Adolfo ;
Vigolo, Paolo ;
Sivolella, Stefano ;
Cavallin, Francesco ;
Katsoulis, Joannis ;
Monaco, Carlo ;
Stellini, Edoardo .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (04) :992-998
[9]   Insertion Torque Value and Implant Stability Quotient: Separate Evaluation and Correlation for Different Clinical Parameters [J].
Ferreira, Jose Joaquim Da Rocha ;
Machado, Luis Filipe Meira .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (04) :812-822
[10]   Implant stability and marginal bone level changes: A 2-year prospective pilot study [J].
Fu, Po-Sung ;
Lan, Ting-Hsun ;
Lai, Pei-Ling ;
Chen, Cheng-Hwei ;
Chen, Jen-Hao ;
Wang, Jen-Chyan ;
Liu, Chih-Te ;
Chen, Wen-Cheng ;
Hung, Chun-Cheng .
JOURNAL OF DENTAL SCIENCES, 2023, 18 (03) :1272-1279