Experimental study of a novel Radiative cooling-Dual phase change material roof under hot summer and warm winter climate

被引:8
作者
Tang, Haida [1 ,2 ]
Chen, Weijie [1 ,2 ]
Lyu, Yuanli [3 ]
Liu, Wenjie [4 ]
Li, Cuimin [5 ]
Li, Chunying [1 ,2 ]
机构
[1] Shenzhen Univ, Sch Architecture & Urban Planning, Shenzhen, Peoples R China
[2] Shenzhen Key Lab Architecture Hlth & Well Being Pr, Shenzhen, Peoples R China
[3] Xihua Univ, Dept Civil Architecture & Environm, Chengdu 610097, Peoples R China
[4] Univ Sci & Technol Beijing, Beijing Adv Innovat Ctr Mat Genome Engn, Ctr Green Innovat, Sch Energy & Environm Engn, Beijing, Peoples R China
[5] Suzhou Univ Sci & Technol, Sch Environm Sci & Engn, Suzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Radiative cooling; Phase change materials; Thermal performance; Building energy saving; THERMAL-ENERGY STORAGE; BUILDINGS; PCM; PERFORMANCE; REDUCTION;
D O I
10.1016/j.jobe.2024.110309
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In hot summer and warm winter climates, phase change materials (PCMs), with their ability to absorb and store thermal energy, can effectively reduce indoor temperature fluctuations and lower cooling loads when applied to roofs. Therefore, this study proposes a novel Radiative cooling-Dual phase change material (RC-DPCM) roof and conducts experimental research on its regulation of indoor and outdoor thermal environments. This energy-efficient roof integrates radiative sky cooling with PCM latent heat storage technologies within a compact building envelope. The innovative dual-PCM configuration can store heat from both indoor sources and outdoor solar radiation during the day through integrated PCM layers. At night, radiative cooling materials emit heat to the deep universe, helping the PCM layers complete solidification. The thermal performance of the RC-DPCM roof was tested in hot summer and warm winter climates compared to other roof designs: a single layer of aluminum (AL) roof, the Aluminum-Thermal insulation (AL-TH) roof, the Radiative cooling (RC) roof, the Radiative cooling-Outside phase change materials (RC-OPCM) roof, and the Radiative cooling-Inside phase change materials (RCIPCM) roof. Results showed that the RC-DPCM roof significantly improved indoor thermal comfort and efficiency. Compared with the AL roof, the RC-DPCM roof reduced the average indoor temperature by 1.13 degrees C (or 2.49 degrees C during working hours) and continuously dissipated heat from the indoor environment to the ambient environment, reducing the cooling load. Additionally, the RC-DPCM roof achieved a 172.9 % average cooling load reduction during working hours, outperforming other roofs, thus demonstrating its potential as an innovative solution for sustainable and energy-efficient buildings. The RC-DPCM roof effectively reduced peak indoor temperatures and cooling load, demonstrating its potential as an innovative solution for sustainable and energy-efficient buildings.
引用
收藏
页数:13
相关论文
共 31 条
[1]  
Alotaibi SS, 2014, INT J ENERG RES, V38, P1, DOI [10.1002/er.3101, 10.1080/03085694.2013.731250]
[2]   Air-conditioning cost saving and CO2 emission reduction prospective of buildings designed with PCM integrated blocks and roofs [J].
Arumugam, Chelliah ;
Shaik, Saboor .
SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2021, 48
[3]   Thermal management of metal roof building using phase change material (PCM) [J].
Boobalakrishnan, P. ;
Kumar, P. Manoj ;
Balaji, G. ;
Jenaris, D. S. ;
Kaarthik, S. ;
Babu, M. Jaya Prakash ;
Karthhik, K. .
MATERIALS TODAY-PROCEEDINGS, 2021, 47 :5052-5058
[4]   Materials used as PCM in thermal energy storage in buildings: A review [J].
Cabeza, L. F. ;
Castell, A. ;
Barreneche, C. ;
de Gracia, A. ;
Fernandez, A. I. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (03) :1675-1695
[5]   Building energy-consumption status worldwide and the state-of-the-art technologies for zero-energy buildings during the past decade [J].
Cao, Xiaodong ;
Dai, Xilei ;
Liu, Junjie .
ENERGY AND BUILDINGS, 2016, 128 :198-213
[6]   Experimental evaluation of heat transfer coefficients between radiant ceiling and room [J].
Causone, Francesco ;
Corgnati, Stefano P. ;
Filippi, Marco ;
Olesen, Bjarne W. .
ENERGY AND BUILDINGS, 2009, 41 (06) :622-628
[7]   Development of radiative cooling and its integration with buildings: A comprehensive review [J].
Chen, Jianheng ;
Lu, Lin .
SOLAR ENERGY, 2020, 212 :125-151
[8]   A Study on Variation of Thermal Characteristics of Insulation Materials for Buildings According to Actual Long-Term Annual Aging Variation [J].
Choi, Hyun-Jung ;
Kang, Jae-Sik ;
Huh, Jung-Ho .
INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2018, 39 (01)
[9]   Dynamic building envelope with PCM for cooling purposes - Proof of concept [J].
de Gracia, Alvaro .
APPLIED ENERGY, 2019, 235 :1245-1253
[10]   A review on phase change energy storage: materials and applications [J].
Farid, MM ;
Khudhair, AM ;
Razack, SAK ;
Al-Hallaj, S .
ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (9-10) :1597-1615