Misclassification of Eyes With Progressive Keratoconus Using the KISA% Index

被引:1
|
作者
Hammoud, Bassel [1 ]
Dupps Jr, William J. [1 ,2 ,3 ]
Scarcelli, Giuliano [4 ]
Randleman, J. Bradley [1 ,2 ]
机构
[1] Cleveland Clin, Cole Eye Inst, 9500 Euclid Ave,i-32, Cleveland, OH 44195 USA
[2] Case Western Reserve Univ, Cleveland Clin, Lerner Coll Med, Cleveland, OH USA
[3] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH USA
[4] Univ Maryland, Fischell Dept Bioengn, College Pk, MD USA
关键词
COLLAGEN CROSS-LINKING; SUBCLINICAL KERATOCONUS; CORNEAL TOMOGRAPHY; ECTASIA; VIDEOKERATOGRAPHY; VALIDATION; CLASSIFICATION; THICKNESS; DIAGNOSIS; SYSTEM;
D O I
10.3928/1081597X-20240726-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the misclassification rate of the keratoconus percentage (KISA%) index efficacy in eyes with progressive keratoconus. Methods: This was a retrospective case-control study of consecutive patients with confirmed progressive keratoconus and a contemporaneous normal control group with 1.00 diopters or greater regular astigmatism. Scheimpflug imaging (Pentacam HR) was obtained for all patients. KISA% index and inferior-superior (IS) values were obtained from the Pentacam topometric/keratoconus staging map. Receiver operating characteristic curves were generated to determine the area under the receiver operating characteristic curve (AUROC), sensitivity, and specificity values. Results: There were 160 eyes from 160 patients evaluated, including 80 eyes from 80 patients with progressive keratoconus and 80 eyes from 80 control patients. There were 20 eyes (25%) with progressive keratoconus misclassified by the KISA% index, with 16 eyes (20%) of the progressive keratoconus cohort classified as normal (ie, KISA% < 60). There were 4 eyes (5%) with progressive keratoconus that would classify as having "normal topography" using the published criteria for very asymmetric ectasia with normal topography of KISA% less than 60 and IS value less than 1.45. All controls had a KISA% index value of less than 15. The optimal cut-off value to distinguish cohorts was 15.31 (AUROC = 0.972, 93.75% sensitivity). KISA% index values of 60 and 100 achieved low sensitivity (80% and 73.75%, respectively). Conclusions: The KISA% index misclassified a significant proportion of eyes with progressive keratoconus as normal. Although highly specific for clinical keratoconus, the KISA% index lacks sensitivity, does not effectively discriminate between normal and abnormal topography, and thus should not be used in large data analysis or artificial intelligence-based modeling.
引用
收藏
页码:e614 / e624
页数:11
相关论文
共 50 条
  • [1] Correlation of the KISA% index and Scheimpflug tomography in 'normal', 'subclinical', 'keratoconus-suspect' and 'clinically manifest' keratoconus eyes
    Steinberg, Johannes
    Aubke-Schultz, Silke
    Frings, Andreas
    Huelle, Jan
    Druchkiv, Vasyl
    Richard, Gisbert
    Katz, Toam
    Linke, Stephan J.
    ACTA OPHTHALMOLOGICA, 2015, 93 (03) : e199 - e207
  • [2] Distinguishing Highly Asymmetric Keratoconus Eyes Using Dual Scheimpflug/Placido Analysis
    Golan, Oren
    Piccinini, Andre L.
    Hwang, Eric S.
    Gonzalez, Ildamaris Montes De Oca
    Krauthammer, Mark
    Khandelwal, Sumitra S.
    Smadja, David
    Randleman, J. Bradley
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 201 : 46 - 53
  • [3] The Location Consistency Index Helps to Distinguish Eyes With Subclinical Keratoconus From Normal Eyes
    Wang, Mengyi
    Shi, Ce
    Zhou, Yuheng
    Ye, Yufeng
    Fan, Xin
    Huang, Huimin
    Yu, Xiangle
    Lu, Fan
    Shen, Meixiao
    JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (01) : 35 - +
  • [4] Screening of Keratoconus Using Autokeratometer and Keratometer Keratoconus Index
    Kojima, Takashi
    Isogai, Naoki
    Nishida, Tomoya
    Nakamura, Tomoaki
    Ichikawa, Kazuo
    DIAGNOSTICS, 2021, 11 (11)
  • [5] Biomechanical Analysis of Tomographically Regular Keratoconus Fellow Eyes Using Corvis ST
    Augustin, Victor A.
    Son, Hyeck-Soo
    Kovalchuk, Bogdana
    Yildirim, Timur Mert
    Koeppe, Maximilian K.
    Auffarth, Gerd U.
    Khoramnia, Ramin
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2023, 240 (08) : 944 - 951
  • [6] Differentiating highly asymmetric keratoconus eyes using a combined Scheimpflug/Placido device
    Golan, Oren
    Levinger, Samuel
    Barequet, Irit S.
    Levinger, Eliya
    Varssano, David
    Randleman, J. Bradley
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (12) : 1588 - 1595
  • [7] Early Tomographic Changes in the Eyes of Patients With Keratoconus
    Shajari, Mehdi
    Jaffary, Irfan
    Herrmann, Kim
    Grunwald, Claudia
    Steinwender, Gernot
    Mayer, Wolfgang J.
    Kohnen, Thomas
    JOURNAL OF REFRACTIVE SURGERY, 2018, 34 (04) : 254 - +
  • [8] Role of Corneal Epithelial Measurements in Differentiating Eyes with Stable Keratoconus from Eyes that Are Progressing
    Santhiago, Marcony R.
    Stival, Larissa R.
    Araujo, Daniella C.
    Kara-Junior, Newton
    Toledo, Marcia C.
    OPHTHALMOLOGY SCIENCE, 2023, 3 (01):
  • [9] Pentacam and vector analysis to evaluate longitudinal corneal tomographical changes in non-progressive keratoconus eyes
    De Bernardo, Maddalena
    Abbinante, Giulia
    Vitiello, Livio
    Rosa, Nicola
    CONTACT LENS & ANTERIOR EYE, 2019, 42 (02) : 232 - 232
  • [10] Discrimination between keratoconus, forme fruste keratoconus, and normal eyes using a novel OCT-based tomographer
    Saad, Alain
    Debellemaniere, Guillaume
    Zeboulon, Pierre
    Rizk, Maria
    Rouger, Helene
    Mazharian, Adrien
    Grise-Dulac, Alice
    Panthier, Christophe
    Gatinel, Damien
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (11) : 1092 - 1097