Sensitivity and quantitativeness of large-volume injection combined with liquid chromatography/high-resolution mass spectrometry for target screening analysis of emerging contaminants

被引:1
作者
Ota, Maho [1 ]
Kasuga, Ikuro [2 ]
Kurisu, Futoshi [3 ]
机构
[1] Univ Tokyo, Grad Sch Engn, Dept Urban Engn, 7-3-1 Hongo, Bunkyo, Tokyo 1138656, Japan
[2] Univ Tokyo, Res Ctr Adv Sci & Technol, 4-6-1 Komaba, Meguro, Tokyo 1538904, Japan
[3] Univ Tokyo, Res Ctr Water Environm Technol, Grad Sch Engn, 7-3-1 Hongo, Bunkyo, Tokyo 1138656, Japan
关键词
Large -volume injection; LC/MS; Target screening analysis; Matrix effect; DATABASE; SAMPLES; DRUGS;
D O I
10.1016/j.envpol.2024.124180
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Solid phase extraction (SPE) has been widely used for pretreatment in target screening (TS) analysis. However, some compounds are difficult to recover by SPE or their recovery is unstable for environmental samples. In this study, we tested large -volume injection (LVI) without SPE for TS analysis of 103 compounds listed by the Ministry of the Environment (Japan)-so-called 'items to be surveyed'-using liquid chromatography highresolution mass spectrometry. We evaluated the limit of quantification (LOQ) by LVI and compared this LOQ with the LOQ by SPE pretreatment using a hydrophilic-lipophilic balance (HLB) combined with activated carbon, which was found previously to afford the best SPE cartridges for target compounds recovery. The LOQ generally decreased as the injection volume increased, and the LOQ was at least 250 times lower for a 500-mu L injection than for a 2-mu L injection for half of the compounds. LVI provided LOQs lower than the predicted no effect concentration for more compounds than the SPE method. The average matrix effect (ME) by LVI was in the range 70%-130% for 69 out of 97 compounds. The ME was higher or lower for some of the remaining compounds, but the ME was in the range 10%-1000% for all 18 water samples for 84 of the 97 compounds. Comparing the ME by LVI and the recovery ratio by the SPE method showed that LVI achieved more accurate quantitation than the SPE method for a larger number of compounds. Therefore, LVI provides better sensitivity and quantitativeness than the SPE method using HLB and activated carbon for TS analysis of as many 'items to be surveyed' as possible.
引用
收藏
页数:7
相关论文
共 19 条
  • [1] Allred BM, 2015, LC GC N AM, V33, P54
  • [2] [Anonymous], 2008, Green paper on the management of bio-waste in the European Union, P1
  • [3] The determination of acrylamide in environmental and drinking waters by large-volume injection - hydrophilic-interaction liquid chromatography and tandem mass spectrometry
    Backe, Will J.
    Yingling, Virginia
    Johnson, Todd
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2014, 1334 : 72 - 78
  • [4] Zwitterionic, Cationic, and Anionic Fluorinated Chemicals in Aqueous Film Forming Foam Formulations and Groundwater from US Military Bases by Nonaqueous Large-Volume Injection HPLC-MS/MS
    Backe, Will J.
    Day, Thomas C.
    Field, Jennifer A.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (10) : 5226 - 5234
  • [5] Is SPE Necessary for Environmental Analysis? A Quantitative Comparison of Matrix Effects from Large-Volume Injection and Solid-Phase Extraction Based Methods
    Backe, Will J.
    Field, Jennifer A.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2012, 46 (12) : 6750 - 6758
  • [6] Analysis of llicit and illicit drugs in waste, surface and lake water samples using large volume direct injection high performance liquid chromatography - Electrospray tandem mass spectrometry (HPLC-MS/MS)
    Berset, Jean-Daniel
    Brenneisen, Rudolf
    Mathieu, Christoph
    [J]. CHEMOSPHERE, 2010, 81 (07) : 859 - 866
  • [7] Fast determination of 40 drugs in water using large volume direct injection liquid chromatography-tandem mass spectrometry
    Boix, Clara
    Ibanez, Maria
    Sancho, Juan V.
    Rambla, Javier
    Aranda, Jose L.
    Ballester, Salome
    Hernandez, Felix
    [J]. TALANTA, 2015, 131 : 719 - 727
  • [8] Wide-scope target screening of > 2000 emerging contaminants in wastewater samples with UPLC-Q-ToF-HRIVIS/MS and smart evaluation of its performance through the validation of 195 selected representative analytes
    Gago-Ferrero, Pablo
    Bletsou, Anna A.
    Damalas, Dimitrios E.
    Aalizadeh, Reza
    Alygizakis, Nikiforos A.
    Singer, Heinz P.
    Hollender, Juliane
    Thomaidis, Nikolaos S.
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2020, 387
  • [9] Novel gas chromatography-mass spectrometry database for automatic identification and quantification of micropollutants
    Kadokami, K
    Tanada, K
    Taneda, K
    Nakagawa, K
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1089 (1-2) : 219 - 226
  • [10] Development of a novel GC/MS database for simultaneous determination of hazardous chemicals
    Kadokami, K
    Tanada, K
    Taneda, K
    Nakagawa, K
    [J]. BUNSEKI KAGAKU, 2004, 53 (06) : 581 - 588