Ammonia recovery via direct contact membrane distillation: Modeling and performance optimization

被引:3
|
作者
Hu, Yuan [1 ]
Loh, Ching Yoong [2 ]
Xie, Ming [2 ]
Chen, Gang [1 ]
Huang, Manhong [1 ]
Qiao, Jinli [1 ]
机构
[1] Donghua Univ, Coll Environm Sci & Engn, Text Pollut Controlling Engn Ctr, Minist Environm Protect, Shanghai 201620, Peoples R China
[2] Univ Bath, Dept Chem Engn, Bath BA2 7AY, England
基金
上海市自然科学基金;
关键词
Ammonia recovery; DCMD; Response surface methodology; Modeling and optimization; Plackett-Burman design; Box-Behnken design; RESPONSE-SURFACE METHODOLOGY; WASTE-WATER; MASS-TRANSFER; MULTIOBJECTIVE OPTIMIZATION; NITROGEN; REMOVAL; STRATEGIES; NUTRIENTS; DESIGN; SYSTEM;
D O I
10.1016/j.jenvman.2024.121683
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ammonia recovery from wastewater has positive environmental benefits, avoiding eutrophication and reducing production energy consumption, which is one of the most effective ways to manage nutrients in wastewater. Specifically, ammonia recovery by membrane distillation has been gradually adopted due to its excellent separation properties for volatile substances. However, the global optimization of direct contact membrane distillation (DCMD) operating parameters to maximize ammonia recovery efficiency (ARE) has not been attempted. In this work, three key operating factors affecting ammonia recovery, i.e., feed ammonia concentration, feed pH, and DCMD running time, were identified from eight factors, by a two-level Plackett-Burman Design (PBD). Subsequently, Box-Behnken design (BBD) under the response surface methodology (RSM) was used to model and optimize the significant operating parameters affecting the recovery of ammonia though DCMD identified by PBD and statistically verified by analysis of variance (ANOVA). Results showed that the model had a high coefficient of determination value (R2 = 0.99), and the interaction between NH4Cl concentration and feed pH had a significant effect on ARE. The optimal operating parameters of DCMD as follows: NH4Cl concentration of 0.46 g/ L, feed pH of 10.6, DCMD running time of 11.3 h, and the maximum value of ARE was 98.46%. Under the optimized conditions, ARE reached up to 98.72%, which matched the predicted value and verified the validity and reliability of the model for the optimization of ammonia recovery by DCMD process.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Optimization of module length for continuous direct contact membrane distillation process
    Ali, A.
    Quist-Jensen, C. A.
    Macedonio, F.
    Drioli, E.
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2016, 110 : 188 - 200
  • [32] Influence of microporous membrane properties on the desalination performance in direct contact membrane distillation
    Li, Lin
    Sirkar, Kamalesh K.
    JOURNAL OF MEMBRANE SCIENCE, 2016, 513 : 280 - 293
  • [33] Modeling and Simulation for Direct Contact Membrane Distillation in Hollow Fiber Modules
    Ibrahim, Salah S.
    Alsalhy, Qusay F.
    AICHE JOURNAL, 2013, 59 (02) : 589 - 603
  • [34] Modeling of desalination using tubular direct contact membrane distillation modules
    Banat, FA
    Abu Al-Rub, FA
    Jumah, R
    Al-Shannag, M
    SEPARATION SCIENCE AND TECHNOLOGY, 1999, 34 (11) : 2191 - 2206
  • [35] Microwave-Induced Desalination via Direct Contact Membrane Distillation
    Roy, Sagar
    Humoud, Madihah Saud
    Intrchom, Worawit
    Mitra, Somenath
    ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2018, 6 (01): : 626 - 632
  • [36] Solar enhanced membrane distillation for ammonia recovery
    Yang, Kai
    Du, Hongang
    Qin, Mohan
    JOURNAL OF MEMBRANE SCIENCE LETTERS, 2023, 3 (01):
  • [37] Water recovery from hydrolysed human urine samples via direct contact membrane distillation using PVDF/PTFE membrane
    Khumalo, Nomcebo
    Nthunya, Lebea
    Derese, Sebastiaan
    Motsa, Machawe
    Verliefde, Arne
    Kuvarega, Alex
    Mamba, Bhekie B.
    Mhlanga, Sabelo
    Dlamini, Derrick S.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2019, 211 : 610 - 617
  • [38] Direct contact membrane distillation (DCMD): Experimental study on the commercial PTFE membrane and modeling
    Hwang, Ho Jung
    He, Ke
    Gray, Stephen
    Zhang, Jianhua
    Moon, Il Shik
    JOURNAL OF MEMBRANE SCIENCE, 2011, 371 (1-2) : 90 - 98
  • [39] Experimental investigation of enhanced direct contact membrane distillation performance through turbulence promoters and structural optimization
    Zhu, Chuan-Yong
    Qin, Jin-Yi
    Gao, Yan-Wen
    Gong, Liang
    JOURNAL OF MEMBRANE SCIENCE, 2025, 723
  • [40] Optimization of morphology and performance of PVDF hollow fiber for direct contact membrane distillation using experimental design
    Song, Zheng Wei
    Jiang, Lan Ying