Towards a net-zero-energy building with smart control of Trombe walls, underground air ducts, and optimal microgrid composed of renewable energy systems

被引:10
作者
Sady, Hamed [1 ]
Rashidi, Saman [1 ]
Rafee, Roohollah [2 ]
机构
[1] Semnan Univ, Fac New Sci & Technol, Dept Energy, Semnan, Iran
[2] Semnan Univ, Fac Mech Engn, Semnan, Iran
关键词
Net zero energy building; Smart temperature control; Trombe wall; Underground duct; Cooling and heating loads; PHASE-CHANGE MATERIALS; EARTH TUBE; SOLAR; OPTIMIZATION; STORAGE;
D O I
10.1016/j.energy.2024.130703
中图分类号
O414.1 [热力学];
学科分类号
摘要
In recent years, permanent outages and lack of access to electricity have been significant problems in most cities of Iran. The increasing growth of fossil fuel consumption made it necessary to change the design of buildings. Designing a net-zero energy building (with natural ventilation and renewable energy systems) is a solution for reducing fossil fuels. In this paper, dynamic energy modeling of the building for the smart operation of the trapezoidal Trombe wall and underground air ducts is performed. In the first step, the Trombe Zones are considered for heating. Then the combination of the Trombe zones with underground air ducts for cooling is simulated. Then the system combination with a solar hot water system to supply hot water energy is evaluated. Finally, the economic analysis of the optimal hybrid system (with a photovoltaic system, wind turbine, battery, and inverter) for supplying the electricity of the building equipped with both passive energy strategies was evaluated by Homer software. The results show that by integrating the Trombe wall, the heating load is reduced by 44 %, and by integrating a coupled geothermal cooling system with the air duct and the Trombe wall, the cooling load is reduced by 39%. Also, the net present cost over the 25-year life of the optimized renewable system is reduced by about 12.5% due to both passive strategies. The average daily electricity energy demand of the base building is equal to 86.37 kWh and for the passive building, it is equal to 67.49 kWh.
引用
收藏
页数:19
相关论文
共 56 条
[31]   Comprehensive analysis and optimization of combined cooling heating and power system integrated with solar thermal energy and thermal energy storage [J].
Liu, Lanhua ;
Wang, Ruilin ;
Wang, Yuhao ;
Li, Wenjia ;
Sun, Jian ;
Guo, Yafei ;
Qu, Wanjun ;
Li, Weiling ;
Zhao, Chuanwen .
ENERGY CONVERSION AND MANAGEMENT, 2023, 275
[32]   Review of solar thermoelectric cooling technologies for use in zero energy buildings [J].
Liu, ZhongBing ;
Zhang, Ling ;
Gong, GuangCai ;
Li, HangXin ;
Tang, GuangFa .
ENERGY AND BUILDINGS, 2015, 102 :207-216
[33]   Investigation on the cooling performance of a buoyancy driven earth-air heat exchanger system and the impact on indoor thermal environment [J].
Long, Tianhe ;
Li, Yongcai ;
Li, Wuyan ;
Liu, Shuli ;
Lu, Jun ;
Zheng, Dimeng ;
Ye, Kai ;
Qiao, Zhenyong ;
Huang, Sheng .
APPLIED THERMAL ENGINEERING, 2022, 207
[34]   A hybrid ensemble learning framework for zero-energy potential prediction of photovoltaic direct-driven air conditioners [J].
Lu, Chujie ;
Li, Sihui ;
Gu, Junhua ;
Lu, Weizhuo ;
Olofsson, Thomas ;
Ma, Jianguo .
JOURNAL OF BUILDING ENGINEERING, 2023, 64
[35]   Trombe walls with phase change materials: A review [J].
Omara, Adil A. M. ;
Abuelnuor, Abuelnuor A. A. .
ENERGY STORAGE, 2020, 2 (06)
[36]   Location optimization of phase change material for thermal energy storage in concrete block for development of energy efficient buildings [J].
Patel, Bhaskar ;
Rathore, Pushpendra Kumar Singh ;
Gupta, Naveen Kumar ;
Sikarwar, Basant Singh ;
Sharma, R. K. ;
Kumar, Rajan ;
Pandey, A. K. .
RENEWABLE ENERGY, 2023, 218
[37]  
Pless Shanti., 2010, NET ZERO ENERGY BUIL
[38]   The impacts of advanced glazing units on annual performance of the Trombe wall systems in cold climates [J].
Pourghorban, Arash ;
Asoodeh, Hedyeh .
SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 51
[39]   Application of different Trombe wall solutions on the reduction of energy load and sustainable development in an eco-resort residential building in Binalood region with a cold and dry climate [J].
Sady, Hamed ;
Rashidi, Saman ;
Rafee, Roohollah .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2023, 30 (26) :68417-68434
[40]   Assessment of the weather research and forecasting model in simulation of rainfall for Khorasan Razavi Province, Iran [J].
Rasoul Sarvestan ;
Mokhtar Karami ;
Reza Javidi Sabbaghian .
Arabian Journal of Geosciences, 2022, 15 (2)