Towards a net-zero-energy building with smart control of Trombe walls, underground air ducts, and optimal microgrid composed of renewable energy systems

被引:10
作者
Sady, Hamed [1 ]
Rashidi, Saman [1 ]
Rafee, Roohollah [2 ]
机构
[1] Semnan Univ, Fac New Sci & Technol, Dept Energy, Semnan, Iran
[2] Semnan Univ, Fac Mech Engn, Semnan, Iran
关键词
Net zero energy building; Smart temperature control; Trombe wall; Underground duct; Cooling and heating loads; PHASE-CHANGE MATERIALS; EARTH TUBE; SOLAR; OPTIMIZATION; STORAGE;
D O I
10.1016/j.energy.2024.130703
中图分类号
O414.1 [热力学];
学科分类号
摘要
In recent years, permanent outages and lack of access to electricity have been significant problems in most cities of Iran. The increasing growth of fossil fuel consumption made it necessary to change the design of buildings. Designing a net-zero energy building (with natural ventilation and renewable energy systems) is a solution for reducing fossil fuels. In this paper, dynamic energy modeling of the building for the smart operation of the trapezoidal Trombe wall and underground air ducts is performed. In the first step, the Trombe Zones are considered for heating. Then the combination of the Trombe zones with underground air ducts for cooling is simulated. Then the system combination with a solar hot water system to supply hot water energy is evaluated. Finally, the economic analysis of the optimal hybrid system (with a photovoltaic system, wind turbine, battery, and inverter) for supplying the electricity of the building equipped with both passive energy strategies was evaluated by Homer software. The results show that by integrating the Trombe wall, the heating load is reduced by 44 %, and by integrating a coupled geothermal cooling system with the air duct and the Trombe wall, the cooling load is reduced by 39%. Also, the net present cost over the 25-year life of the optimized renewable system is reduced by about 12.5% due to both passive strategies. The average daily electricity energy demand of the base building is equal to 86.37 kWh and for the passive building, it is equal to 67.49 kWh.
引用
收藏
页数:19
相关论文
共 56 条
[21]   Sustainability analysis of zero energy consumption data centers with free cooling, waste heat reuse and renewable energy systems: A feasibility study [J].
Gugul, Gul Nihal ;
Gokcul, Furkan ;
Eicker, Ursula .
ENERGY, 2023, 262
[22]   Optimal planning and design of a renewable energy based supply system for microgrids [J].
Hafez, Omar ;
Bhattacharya, Kankar .
RENEWABLE ENERGY, 2012, 45 :7-15
[23]   Fluid dynamics analysis for different photovoltaic panel locations in solar chimney [J].
Haghighat, Siavash ;
Kasaeian, Alibakhsh ;
Pourfayaz, Fathollah ;
Shandost, Bagher Mokhtari .
ENERGY CONVERSION AND MANAGEMENT, 2019, 191 :71-79
[24]  
Huovila P., 2007, BUILD CLIM CHANG STA
[25]   Heuristic Approach for Net-Zero Energy Residential Buildings in Arid Region Using Dual Renewable Energy Sources [J].
Ismaeil, Esam M. H. ;
Sobaih, Abu Elnasr E. .
BUILDINGS, 2023, 13 (03)
[26]   Design feasibility of a net-zero energy neighborhood in Qazvin [J].
Janzadeh, Amirhossein ;
Zandieh, Mahdi .
ENERGY EFFICIENCY, 2021, 14 (01)
[27]   Concept of net zero energy buildings (NZEB) - A literature review [J].
Jaysawal, Rajan Kumar ;
Chakraborty, Suprava ;
Elangovan, D. ;
Padmanaban, Sanjeevikumar .
CLEANER ENGINEERING AND TECHNOLOGY, 2022, 11
[28]  
Kamyabi S, 2016, Geographical Territory., V13, P91
[29]   Evaluation of a Trombe wall system in a subtropical location [J].
Krueger, Eduardo ;
Suzuki, Eimi ;
Matoski, Adalberto .
ENERGY AND BUILDINGS, 2013, 66 :364-372
[30]   The cooling and heating potential of an earth tube system in buildings [J].
Lee, Kwang Ho ;
Strand, Richard K. .
ENERGY AND BUILDINGS, 2008, 40 (04) :486-494