Evaluation of image-guided and surface-guided radiotherapy for breast cancer patients treated in deep inspiration breath-hold: A single institution experience

被引:19
|
作者
Penninkhof, Joan [1 ]
Fremeijer, Kimm [1 ]
Harten, Kirsten Offereins-van [1 ]
van Wanrooij, Cynthia [1 ]
Quint, Sandra [1 ]
Kunnen, Britt [1 ]
Hoffmans-Holtzer, Nienke [1 ]
Swaak, Annemarie [1 ]
Baaijens, Margreet [1 ]
Dirkx, Maarten [1 ]
机构
[1] Erasmus MC, Canc Inst, Dept Radiat Oncol, Dr Molewaterpl 40, NL-3015 GD Rotterdam, Netherlands
来源
TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY | 2022年 / 21卷
关键词
Breath; -hold; Surface -guided radiotherapy; DIBH; Breast; REPRODUCIBILITY; IRRADIATION; STABILITY; ACCURACY; SETUP; DIBH;
D O I
10.1016/j.tipsro.2022.02.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: Nowadays, deep inspiratory breath-hold is a common technique to reduce heart dose in left-sided breast radiotherapy. This study evaluates the evolution of the breath-hold technique in our institute, from portal imaging during dose delivery to continuous monitoring with surface-guided radiotherapy (SGRT). Materials and methods: Setup data and portal imaging results were analyzed for 98 patients treated before 2014, and SGRT data for 228 patients treated between 2018 and 2020. For the pre-SGRT group, systematic and random setup errors were calculated for different correction protocols. Residual errors and reproducibility of breathholds were evaluated for both groups. The benefit of using SGRT for initial positioning was evaluated for another cohort of 47 patients. Results: Online correction reduced the population mean error from 3.9 mm (no corrections) to 1.4 mm. Despite online setup correction, deviations greater than 3 mm were observed in about 10% and 20% of the treatment beams in ventral-dorsal and cranial-caudal directions, respectively. However, these percentages were much smaller than with offline protocols or no corrections. Mean absolute differences between breath-holds within a fraction were smaller in the SGRT-group (1.69 mm) than in the pre-SGRT-group (2.10 mm), and further improved with addition of visual feedback (1.30 mm). SGRT for positioning did not improve setup accuracy, but slightly reduced the time for imaging and setup correction, allowing completion within 3.5 min for 95% of fractions. Conclusion: For accurate radiotherapy breast treatments using deep inspiration breath-hold, daily imaging and correction is required. SGRT provides accurate information on patient positioning during treatment and improves patient compliance with visual feedback.
引用
收藏
页码:51 / 57
页数:7
相关论文
共 50 条
  • [31] A Potential Pitfall and Clinical Solutions in Surface -Guided Deep Inspiration Breath Hold Radiation Therapy for Left -Sided Breast Cancer
    Zeng, Chuan
    Fan, Qiyong
    Li, Xiang
    Song, Yulin
    Kuo, Licheng
    Aristophanous, Michalis
    Cervino, Laura I.
    Hong, Linda
    Powell, Simon
    Li, Guang
    ADVANCES IN RADIATION ONCOLOGY, 2023, 8 (06)
  • [32] Advantage of deep inspiration breath hold in left-sided breast cancer patients treated with 3D conformal radiotherapy
    Lastrucci, Luciana
    Borghesi, Simona
    Bertocci, Silvia
    Gasperi, Chiara
    Rampini, Andrea
    Buonfrate, Giovanna
    Pernici, Paola
    De Majo, Roberta
    Gennari, Pietro Giovanni
    TUMORI JOURNAL, 2017, 103 (01): : 72 - 75
  • [33] Single-institution report of setup margins of voluntary deep-inspiration breath-hold (DIBH) whole breast radiotherapy implemented with real-time surface imaging
    Xiao, Annie
    Crosby, Jennie
    Malin, Martha
    Kang, Hyejoo
    Washington, Maxine
    Hasan, Yasmin
    Chmura, Steven J.
    Al-Hallaq, Hania A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 205 - 213
  • [34] Dose Sparing Potential of Deep Inspiration Breath-hold Technique for Left Breast Cancer Radiotherapy Organs-at-risk
    Lawler, Gavin
    Leech, Michelle
    ANTICANCER RESEARCH, 2017, 37 (02) : 883 - 890
  • [35] Dosimetry impact of gating latency in cine magnetic resonance image guided breath-hold pancreatic cancer radiotherapy
    Hu, Panpan
    Li, Xiaoyang
    Liu, Wei
    Yan, Bing
    Xue, Xudong
    Yang, Fei
    Ford, John Chetley
    Portelance, Lorraine
    Yang, Yidong
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (05)
  • [36] Assessment of set-up variability during deep inspiration breath hold radiotherapy for breast cancer patients by 3D-surface imaging
    Betgen, Anja
    Alderliesten, Tanja
    Sonke, Jan-Jakob
    van Vliet-Vroegindeweij, Corine
    Bartelink, Harry
    Remeijer, Peter
    RADIOTHERAPY AND ONCOLOGY, 2013, 106 (02) : 225 - 230
  • [37] Evaluation of an in-house self-held respiration monitoring device for deep inspiration breath hold techniques for radiotherapy of patients with cancer of the left breast
    Chan, Yuen Yan
    Ku, Ki Man
    Ng, Yin Ping
    Yu, Siu Ki Ben
    Kong, Chi Wah Tony
    Mui, Wing Lun Alan
    Wong, Chun Man Cornel
    Kong, Sze Wan
    Wong, Sze Ming
    Chiu, George
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2020, 19 (02) : 122 - 126
  • [38] Treatment planning and evaluation of gated radiotherapy in left-sided breast cancer patients using the Catalyst™/Sentinel™ system for deep inspiration breath-hold (DIBH)
    Schoenecker, S.
    Walter, F.
    Freislederer, P.
    Marisch, C.
    Scheithauer, H.
    Harbeck, N.
    Corradini, S.
    Belka, C.
    RADIATION ONCOLOGY, 2016, 11
  • [39] Selection criteria and method for deep inspiration breath-hold in patients with left breast cancer undergoing PMRT/IMRT
    Zhou, Yingying
    Xu, Jinfeng
    Xu, Fumin
    Li, Yanning
    Li, Huali
    Pan, Lisheng
    Li, Yang
    Cao, Shuyi
    Cai, Longmei
    Yang, Lin
    Chen, Bo
    Wang, Hongmei
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2024, 48
  • [40] Deep inspiration breath-hold radiation therapy in left-sided breast cancer patients: a single-institution retrospective dosimetric analysis of organs at risk doses
    Wolf, Jule
    Stoller, Sabine
    Luebke, Joerdis
    Rothe, Thomas
    Serpa, Marco
    Scholber, Jutta
    Zamboglou, Constantinos
    Gkika, Eleni
    Baltas, Dimos
    Juhasz-Boess, Ingolf
    Verma, Vivek
    Krug, David
    Grosu, Anca-Ligia
    Nicolay, Nils H.
    Sprave, Tanja
    STRAHLENTHERAPIE UND ONKOLOGIE, 2023, 199 (04) : 379 - 388