Evaluation of image-guided and surface-guided radiotherapy for breast cancer patients treated in deep inspiration breath-hold: A single institution experience

被引:19
|
作者
Penninkhof, Joan [1 ]
Fremeijer, Kimm [1 ]
Harten, Kirsten Offereins-van [1 ]
van Wanrooij, Cynthia [1 ]
Quint, Sandra [1 ]
Kunnen, Britt [1 ]
Hoffmans-Holtzer, Nienke [1 ]
Swaak, Annemarie [1 ]
Baaijens, Margreet [1 ]
Dirkx, Maarten [1 ]
机构
[1] Erasmus MC, Canc Inst, Dept Radiat Oncol, Dr Molewaterpl 40, NL-3015 GD Rotterdam, Netherlands
来源
TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY | 2022年 / 21卷
关键词
Breath; -hold; Surface -guided radiotherapy; DIBH; Breast; REPRODUCIBILITY; IRRADIATION; STABILITY; ACCURACY; SETUP; DIBH;
D O I
10.1016/j.tipsro.2022.02.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: Nowadays, deep inspiratory breath-hold is a common technique to reduce heart dose in left-sided breast radiotherapy. This study evaluates the evolution of the breath-hold technique in our institute, from portal imaging during dose delivery to continuous monitoring with surface-guided radiotherapy (SGRT). Materials and methods: Setup data and portal imaging results were analyzed for 98 patients treated before 2014, and SGRT data for 228 patients treated between 2018 and 2020. For the pre-SGRT group, systematic and random setup errors were calculated for different correction protocols. Residual errors and reproducibility of breathholds were evaluated for both groups. The benefit of using SGRT for initial positioning was evaluated for another cohort of 47 patients. Results: Online correction reduced the population mean error from 3.9 mm (no corrections) to 1.4 mm. Despite online setup correction, deviations greater than 3 mm were observed in about 10% and 20% of the treatment beams in ventral-dorsal and cranial-caudal directions, respectively. However, these percentages were much smaller than with offline protocols or no corrections. Mean absolute differences between breath-holds within a fraction were smaller in the SGRT-group (1.69 mm) than in the pre-SGRT-group (2.10 mm), and further improved with addition of visual feedback (1.30 mm). SGRT for positioning did not improve setup accuracy, but slightly reduced the time for imaging and setup correction, allowing completion within 3.5 min for 95% of fractions. Conclusion: For accurate radiotherapy breast treatments using deep inspiration breath-hold, daily imaging and correction is required. SGRT provides accurate information on patient positioning during treatment and improves patient compliance with visual feedback.
引用
收藏
页码:51 / 57
页数:7
相关论文
共 50 条
  • [21] yStereoscopic X-ray image and thermo-optical surface guidance for breast cancer radiotherapy in deep inspiration breath-hold
    Buschmann, Martin
    Kauer-Dorner, Daniela
    Konrad, Stefan
    Georg, Dietmar
    Widder, Joachim
    Knaeusl, Barbara
    STRAHLENTHERAPIE UND ONKOLOGIE, 2024, 200 (04) : 306 - 313
  • [22] Comparison of cone beam computed tomography (CBCT)-based image guided radiotherapy approaches in the reduction of setup uncertainties during deep inspiration breath-hold radiotherapy (DIBH-RT) for left breast cancer
    Abubakar, Auwal
    Shaukat, Shazril Imran
    Karim, Noor Khairiah A.
    Kassim, Mohammed Zakir
    Appalanaido, Gokula Kumar
    Zin, Hafiz Mohd
    RADIATION PHYSICS AND CHEMISTRY, 2023, 212
  • [23] A Prospective Study on the Use of Deep Inspiration Breath-Hold Technique in External Beam Radiotherapy for Breast Cancer
    Jose, Nijo
    Jayashree, N. P.
    Lewis, Shirley
    Sharan, Krishna
    Velu, Umesh
    Reddy, Anusha
    Singh, Anshul
    Rao, Shreekripa
    Shambhavi, C.
    Nisha, Rachel
    Nair, Sarath
    Nagesh, Jyothi
    Chandraguthi, Srinidhi
    SOUTH ASIAN JOURNAL OF CANCER, 2024,
  • [24] Automatically gated image-guided breath-hold IMRT is a fast, precise, and dosimetrically robust treatment for lung cancer patients
    Simeonova-Chergou, Anna
    Jahnke, Anika
    Siebenlist, Kerstin
    Stieler, Florian
    Mai, Sabine
    Boda-Heggemann, Judit
    Wenz, Frederik
    Lohr, Frank
    Jahnke, Lennart
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (03) : 166 - 173
  • [25] Setup margins based on the inter- and intrafractional setup error of left-sided breast cancer radiotherapy using deep inspiration breath-hold technique (DIBH) and surface guided radiotherapy (SGRT)
    Rudat, Volker
    Shi, Yanyan
    Zhao, Ruping
    Yu, Wei
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (06):
  • [26] The necessity of using deep inspiration breath-hold in the radiotherapy of left breast cancer patients who undergo the UK FAST trial
    Hafez, Abdelrahman
    Abdelaziz, Dina M.
    Khalil, Magdy M.
    El-Nagdy, Mohamed S.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (01)
  • [27] Estimation of heart-position variability in 3D-surface-image-guided deep-inspiration breath-hold radiation therapy for left-sided breast cancer
    Alderliesten, Tanja
    Betgen, Anja
    Elkhuizen, Paula H. M.
    van Vliet-Vroegindeweij, Corine
    Remeijer, Peter
    RADIOTHERAPY AND ONCOLOGY, 2013, 109 (03) : 442 - 447
  • [28] Geometrical uncertainty of heart position in deep-inspiration breath-hold radiotherapy of left-sided breast cancer patients
    Koivumaki, Tuomas
    Tujunen, Juuso
    Viren, Tuomas
    Heikkila, Janne
    Seppala, Jan
    ACTA ONCOLOGICA, 2017, 56 (06) : 879 - 883
  • [29] Evaluation of surface image guidance and Deep inspiration Breath Hold technique for breast treatments with Halcyon
    Crop, Frederik
    Laffarguette, Julien
    Achag, Ilias
    Pasquier, David
    Mirabel, Xavier
    Cayez, Romain
    Lacornerie, Thomas
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 108
  • [30] Evaluation of the accuracy of heart dose prediction by machine learning for selecting patients not requiring deep inspiration breath-hold radiotherapy after breast cancer surgery
    Kamizaki, Ryo
    Kuroda, Masahiro
    Al-Hammad, Wlla E.
    Tekiki, Nouha
    Ishizaka, Hinata
    Kuroda, Kazuhiro
    Sugimoto, Kohei
    Oita, Masataka
    Tanabe, Yoshinori
    Barham, Majd
    Sugianto, Irfan
    Nakamitsu, Yuki
    Hirano, Masaki
    Muto, Yuki
    Ihara, Hiroki
    Sugiyama, Soichi
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2023, 26 (05)