Evaluation of image-guided and surface-guided radiotherapy for breast cancer patients treated in deep inspiration breath-hold: A single institution experience

被引:19
|
作者
Penninkhof, Joan [1 ]
Fremeijer, Kimm [1 ]
Harten, Kirsten Offereins-van [1 ]
van Wanrooij, Cynthia [1 ]
Quint, Sandra [1 ]
Kunnen, Britt [1 ]
Hoffmans-Holtzer, Nienke [1 ]
Swaak, Annemarie [1 ]
Baaijens, Margreet [1 ]
Dirkx, Maarten [1 ]
机构
[1] Erasmus MC, Canc Inst, Dept Radiat Oncol, Dr Molewaterpl 40, NL-3015 GD Rotterdam, Netherlands
来源
TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY | 2022年 / 21卷
关键词
Breath; -hold; Surface -guided radiotherapy; DIBH; Breast; REPRODUCIBILITY; IRRADIATION; STABILITY; ACCURACY; SETUP; DIBH;
D O I
10.1016/j.tipsro.2022.02.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: Nowadays, deep inspiratory breath-hold is a common technique to reduce heart dose in left-sided breast radiotherapy. This study evaluates the evolution of the breath-hold technique in our institute, from portal imaging during dose delivery to continuous monitoring with surface-guided radiotherapy (SGRT). Materials and methods: Setup data and portal imaging results were analyzed for 98 patients treated before 2014, and SGRT data for 228 patients treated between 2018 and 2020. For the pre-SGRT group, systematic and random setup errors were calculated for different correction protocols. Residual errors and reproducibility of breathholds were evaluated for both groups. The benefit of using SGRT for initial positioning was evaluated for another cohort of 47 patients. Results: Online correction reduced the population mean error from 3.9 mm (no corrections) to 1.4 mm. Despite online setup correction, deviations greater than 3 mm were observed in about 10% and 20% of the treatment beams in ventral-dorsal and cranial-caudal directions, respectively. However, these percentages were much smaller than with offline protocols or no corrections. Mean absolute differences between breath-holds within a fraction were smaller in the SGRT-group (1.69 mm) than in the pre-SGRT-group (2.10 mm), and further improved with addition of visual feedback (1.30 mm). SGRT for positioning did not improve setup accuracy, but slightly reduced the time for imaging and setup correction, allowing completion within 3.5 min for 95% of fractions. Conclusion: For accurate radiotherapy breast treatments using deep inspiration breath-hold, daily imaging and correction is required. SGRT provides accurate information on patient positioning during treatment and improves patient compliance with visual feedback.
引用
收藏
页码:51 / 57
页数:7
相关论文
共 50 条
  • [1] Dose coverage and breath-hold analysis of breast cancer patients treated with surface-guided radiotherapy
    Dekker, Janita
    Essers, Marion
    Verheij, Marcel
    Kusters, Martijn
    de Kruijf, Willy
    RADIATION ONCOLOGY, 2023, 18 (01)
  • [2] Accuracy and potential improvements of surface-guided breast cancer radiotherapy in deep inspiration breath-hold with daily image-guidance
    Nankali, Saber
    Hansen, Rune
    Worm, Esben
    Yates, Esben S.
    Thomsen, Mette Skovhus
    Offersen, Birgitte
    Poulsen, Per Rugaard
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (19)
  • [3] Dose coverage and breath-hold analysis of breast cancer patients treated with surface-guided radiotherapy
    Janita Dekker
    Marion Essers
    Marcel Verheij
    Martijn Kusters
    Willy de Kruijf
    Radiation Oncology, 18
  • [4] Dosimetric effects of intrafractional isocenter variation during deep inspiration breath-hold for breast cancer patients using surface-guided radiotherapy
    Kugele, Malin
    Edvardsson, Anneli
    Berg, Lovisa
    Alkner, Sara
    Ljus, Carina Andersson
    Ceberg, Sofie
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (01): : 25 - 38
  • [5] Impact of deep inspiration breath hold, surface-guided radiotherapy, and daily CBCT on the organs at risk in breast cancer radiotherapy
    Rudat, Volker
    Zhao, Ruping
    Wang, Bin
    Zhang, Lihua
    Shi, Yanyan
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [6] Surface guided ring gantry radiotherapy in deep inspiration breath hold for breast cancer patients
    Kadhim, Mustafa
    Haraldsson, Andre
    Kugele, Malin
    Enocson, Hedda
    Back, Sven
    Ceberg, Sofie
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (10):
  • [7] Surface-guided radiotherapy systems in locoregional deep inspiration breath hold radiotherapy for breast cancer - a multicenter study on the setup accuracy
    Laaksomaa, Marko
    Aula, Antti
    Sarudis, Sebastian
    Keyrilainen, Jani
    Ahlroth, Jenni
    Murtola, Anna
    Pynnonen, Kiira
    Lehtonen, Turkka
    Bjorkqvist, Mikko
    Jarvinen, Lauri
    Rossi, Maija
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2024, 29 (02) : 176 - 186
  • [8] A uniform and versatile surface-guided radiotherapy procedure and workflow for high-quality breast deep-inspiration breath-hold treatment in a multi-center institution
    Li, Guang
    Lu, Wei
    O'Grady, Kyle
    Yan, Iris
    Yorke, Ellen
    Arriba, Laura I. Cervino
    Powell, Simon
    Hong, Linda
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (03):
  • [9] Dosimetric Evaluation of Deep Inspiration Breath-Hold Technique for Breast Cancer Radiotherapy: A Single-Center Experience
    Temelli, Oztun
    Demirtas, Mehmet
    Ugurlu, Berat Tugrul
    Pepele, Eda Kaya
    Yaprak, Bahaddin
    Gulbas, Hulya
    Eraslan, Fatma Aysun
    Gurocak, Simay
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2020, 35 (04): : 444 - 450
  • [10] Evidence-based region of interest (ROI) definition for surface-guided radiotherapy (SGRT) of abdominal cancers using deep-inspiration breath-hold (DIBH)
    Song, Yulin
    Zhai, Xingchen
    Liang, Yubei
    Zeng, Chuan
    Mueller, Boris
    Li, Guang
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (11):