Evaluation of Intra-Aneurysmal Residual Blood Flow with the iMSDE T1-Black Blood Imaging after Flow Diverter Treatment

被引:1
|
作者
Suzuki, Yume [1 ]
Toma, Naoki [1 ]
Inoue, Katsuhiro [2 ]
Ichikawa, Tomonori [1 ]
Nishikawa, Hirofumi [1 ]
Miura, Yoichi [1 ]
Fujimoto, Masashi [1 ]
Yasuda, Ryuta [1 ]
Maeda, Masayuki [3 ]
Suzuki, Hidenori [1 ]
机构
[1] Mie Univ, Grad Sch Med, Dept Neurosurg, 2 174,Edobashi, Tsu, Mie 5148507, Japan
[2] Mie Univ Hosp, Dept Radiol, Tsu, Mie, Japan
[3] Mie Univ, Grad Sch Med, Dept Neuroradiol, Tsu, Mie, Japan
关键词
cerebral aneurysm; flow diverter; thrombosis; MRI; DRIVEN-EQUILIBRIUM IMSDE; INTRACRANIAL ANEURYSMS; PIPELINE EMBOLIZATION; ENDOVASCULAR TREATMENT; ANTIPLATELET THERAPY; CEREBRAL ANEURYSMS; RUPTURE; DEVICE; FEASIBILITY; STENT;
D O I
10.5797/jnet.oa.2023-0016
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: We aimed to evaluate the efficacy of the "improved motion-sensitized driven-equilibrium (iMSDE)"-prepared T1-weighted black blood (T1-BB) MRI for monitoring treatment effect with a flow diverter (FD) for cerebral aneurysms. Methods: Following the exclusion of concomitant coiling and retreatment cases from 60 consecutive cases of cerebral aneurysms treated with FDs at our institution, 32 with imaging data were included in the analysis. Detectability of residual blood flow within the aneurysms was validated as follows: 1) comparison of MRI sequences (iMSDE-prepared T1-BB images, T1-weighted images [ T1WI], and time-of-flight [ TOF]-MRA) in cases of incompletely occluded aneurysms and 2) comparison of angiography and MRI sequences in the same period. Results: 1) The probability of diagnosing intra-aneurysmal blood flow was significantly higher with iMSDE-prepared T1-BB (iMSDE-prepared T1-BB vs. T1WI, p <0.001; iMSDE-prepared T1-BB vs. TOF-MRA, p <0.001). 2) The diagnostic accuracy of residual aneurysmal blood flow was significantly higher with iMSDE-prepared T1-BB than that with T1WI (p = 0.032). Furthermore, in cases of incomplete occlusion, the probability of detecting intra-aneurysmal blood flow was significantly higher with iMSDE-prepared T1-BB (iMSDE-prepared T1-BB vs. T1WI, p <0.001; iMSDE-prepared T1-BB vs. TOF-MRA, p = 0.023). Conclusion: Our results demonstrated that iMSDE-prepared T1-BB could help distinguish between blood flow and thrombus within the aneurysms after FD treatment, especially in the early stages of FD treatment.
引用
收藏
页码:159 / 166
页数:8
相关论文
共 24 条
  • [21] Preoperative Assessment of Blood Vessels and Intratumoral Microbleeds in Brain Tumors Based on a 3D Contrast-Enhanced T1-Weighted Flow-Sensitive Black-Blood Sequence
    Cao, Xin
    Lv, Kun
    Yin, Xuyang
    Cao, Yunxi
    Xu, Siting
    Feng, Zhe
    Han, Yan
    Tang, Ye
    Geng, Daoying
    Zhang, Jun
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (05) : 1543 - 1551
  • [22] Use of 3-Dimensional, Black-Blood, Contrast-Enhanced, T1-Weighted Magnetic Resonance Imaging to Identify Vascular Occlusion in the Posterior Circulation After Acute Ischemic Stroke
    Chung, Gyung Ho
    Hwang, Seung Bae
    Kwak, Hyo Sung
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2019, 28 (11)
  • [23] T(Rho) And Magnetization Transfer And INvErsion Recovery (TRAMINER)-Prepared Imaging: A Novel Contrast-Enhanced Flow-Independent Dark-Blood Technique for the Evaluation of Myocardial Late Gadolinium Enhancement in Patients With Myocardial Infarction
    Muscogiuri, Giuseppe
    Rehwald, Wolfgang G.
    Schoepf, U. Joseph
    Suranyi, Pal
    Litwin, Sheldon E.
    De Cecco, Carlo N.
    Wichmann, Julian L.
    Mangold, Stefanie
    Caruso, Damiano
    Fuller, Stephen R.
    Bayer, Richard R.
    Varga-Szemes, Akos
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (05) : 1429 - 1437
  • [24] Cervical carotid plaque evaluation using 3D T1-weighted black-blood magnetic resonance imaging: Comparison of turbo field-echo and turbo spin-echo sequences
    Inoue, Katsuhiro
    Maeda, Masayuki
    Umino, Maki
    Takase, Shinichi
    Yamahata, Tsunehiro
    Sakuma, Hajime
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (05) : 1035 - 1039