Spectrum Construction Methods Improving Gamma-Ray Detection Efficiency for Pixelated CZT Detectors

被引:1
作者
Xiang, Yu [1 ,2 ,3 ,4 ]
Jiang, Xiaopan [1 ,3 ,4 ,5 ]
Feng, Baotong [3 ,4 ,5 ]
Li, Daowu [3 ,4 ,5 ]
Huang, Xianchao [3 ,4 ,5 ]
Li, Xiaoxuan [2 ,3 ,4 ]
Zhang, Zhiming [1 ,2 ,3 ,4 ]
Wei, Cunfeng [1 ,2 ,3 ,4 ]
Wei, Long [1 ,2 ,3 ,4 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, Beijing Engn Res Ctr Radiog Tech & Equipment, Beijing 100049, Peoples R China
[2] Univ Chinese Acad Sci, Sch Nucl Sci & Technol, Beijing 100049, Peoples R China
[3] Jinan Lab Appl Nucl Sci, Jinan 250131, Peoples R China
[4] CAEA Ctr Excellence Nucl Technol Applicat Nucl Det, Beijing 100049, Peoples R China
[5] Chinese Acad Sci, Inst High Energy Phys, Beijing Engn Res Ctr Radiog Tech & Equipment, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
Detectors; Gamma-rays; Image quality; Scattering; Monte Carlo methods; Geometry; Sensitivity; Energy combination sums; energy sums; gamma-ray detection; Monte Carlo simulation; pixelated cadmium zinc telluride (CdZnTe) detector; spectrum construction method; RESOLUTION;
D O I
10.1109/TNS.2024.3381164
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Two spectrum construction methods are introduced, which can mitigate the effect of Compton scattering and charge sharing on the photopeak detection efficiency of gamma rays for pixelated cadmium zinc telluride (CdZnTe) detectors. Energy sums and energy combination sums are used for spectrum construction, respectively. Monte Carlo simulations have been done to evaluate their effectiveness. A model of a $22\times 22\times15$ mm pixelated CZT detector was created with an $11\times11$ -pixel array in the simulations. It is confirmed that the spectrum constructed by energy combination sums functions well under high-intensity and high-energy gamma-ray radiation, while the spectrum from energy sums is functional only under low-intensity radiation. What is more, it is found that the detection efficiency improvement brought by the two methods will be reduced when the energy resolution of the detector gets worse. The best detection efficiency for 662-keV gamma rays achieved by the spectrum consisting of energy combination sums is 14.4%, much higher than the one from the sum of each pixel's spectrum (SEPS), which is 5.9%.
引用
收藏
页码:876 / 883
页数:8
相关论文
共 35 条
[1]   Potentialities of High-Resolution 3-D CZT Drift Strip Detectors for Prompt Gamma-Ray Measurements in BNCT [J].
Abbene, Leonardo ;
Principato, Fabio ;
Buttacavoli, Antonino ;
Gerardi, Gaetano ;
Bettelli, Manuele ;
Zappettini, Andrea ;
Altieri, Saverio ;
Auricchio, Natalia ;
Caroli, Ezio ;
Zanettini, Silvia ;
Protti, Nicoletta .
SENSORS, 2022, 22 (04)
[2]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[3]   Recent progress in CdZnTe based room temperature detectors for nuclear radiation monitoring [J].
Alam, Md Didarul ;
Nasim, Syeda S. ;
Hasan, Samiul .
PROGRESS IN NUCLEAR ENERGY, 2021, 140
[4]   CHARGE-TRANSPORT IN ARRAYS OF SEMICONDUCTOR GAMMA-RAY DETECTORS [J].
BARRETT, HH ;
ESKIN, JD ;
BARBER, HB .
PHYSICAL REVIEW LETTERS, 1995, 75 (01) :156-159
[5]  
Brown S., 2017, Ph.D. dissertation, P89
[6]   CD1-XZNXTE4 GAMMA-RAY DETECTORS [J].
BUTLER, JF ;
LINGREN, CL ;
DOTY, FP .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :605-609
[7]  
BUTLER JF, 1991, CONFERENCE RECORD OF THE 1991 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE, VOLS 1-3, P129, DOI 10.1109/NSSMIC.1991.258906
[8]   Development of Large Volume, High Performance Monolithic CZT Radiation Detector [J].
Chen, Henry ;
Li, Handong ;
Reed, Michael D. ;
Sundaram, Arun G. ;
Eger, John ;
Hugg, James W. ;
Abbaszadeh, Shiva ;
Li, Mohan ;
Montemont, Guillaume ;
Verger, Loick ;
Zhu, Yuefeng ;
He, Zhong .
HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XX, 2018, 10762
[9]   PIXELLATED CDZNTE DETECTOR ARRAYS [J].
DOTY, FP ;
BARBER, HB ;
AUGUSTINE, FL ;
BUTLER, JF ;
APOTOVSKY, BA ;
YOUNG, ET ;
HAMILTON, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3) :356-360
[10]   Monte Carlo investigation of the charge sharing effects in 3-D position sensitive CdZnTe gamma ray spectrometers [J].
Du, YF ;
He, Z ;
Li, W ;
Knoll, GF ;
Wehe, DK .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) :844-847