Temporal Trends in the Outcomes of Percutaneous Coronary Intervention With Zotarolimus Eluting Stents Versus Everolimus Eluting Stents: A Meta-Analysis of Randomized Controlled Trials

被引:1
作者
Basit, Jawad [1 ,2 ]
Ahmed, Mushood [1 ]
Shafiq, Aimen [3 ]
Zaheer, Zaofashan [4 ]
Nashwan, Abdulqadir J. [5 ]
Ahmed, Aleena [4 ]
Hamza, Mohammad [6 ]
Naseer, Usman [7 ]
Ali, Shafaqat [8 ]
Gupta, Neelesh [9 ]
Sattar, Yasar [10 ]
Kawsara, Akram [10 ]
Daggubati, Ramesh [10 ]
Alraies, M. Chadi [11 ]
机构
[1] Rawalpindi Med Univ, Dept Med, Rawalpindi, Pakistan
[2] Cardiovasc Analyt Grp, Canterbury, England
[3] Dow Univ Hlth Sci, Dept Med, Karachi, Pakistan
[4] King Edward Med Univ, Dept Med, Lahore, Pakistan
[5] Hamad Med Corp, Doha, Qatar
[6] Guthrie Med Grp, Cortland, NY USA
[7] USD, Sanford Sch Med, Dept Cardiol, Sioux Falls, SD USA
[8] Louisiana State Univ, Dept Internal Med, Shreveport, LA USA
[9] Univ Nevada Las Vegas, Kirk Kerkorian Sch Med, Dept Cardiol, Las Vegas, NV USA
[10] West Virginia Univ, Dept Intervent Cardiol, Morgantown, WV USA
[11] Wayne State Univ, Detroit Med Ctr, Dept Cardiol, Detroit, MI USA
关键词
Everolimus-eluting stents (EES); major adverse cardiovascular events (MACE); meta-analysis; randomized controlled trials; target vessel myocardial infarction (TVMI); Zotarolimus-eluting stents (ZES); REAL-WORLD PATIENTS; 2-YEAR FOLLOW-UP; XIENCE V STENTS; DUTCH PEERS; RESOLUTE INTEGRITY; PROMUS ELEMENT; ALL-COMERS; DRUG; THROMBOSIS; SAFETY;
D O I
10.1002/clc.24306
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Long-term follow-up results of various trials comparing Zotarolimus eluting stents (ZES) with Everolimus eluting stents (EES) have been published recently. Additionally, over the last decade, there have been new trials comparing the ZES with various commercially available EES. We aim to conduct an updated meta-analysis in light of new evidence from randomized controlled trials (RCTs) to provide comprehensive evidence regarding the temporal trends in the clinical outcomes. Methods: A comprehensive literature search was conducted across PubMed, Cochrane, and Embase. RCTs comparing ZES with EES for short (<2 years), intermediate (2-3 years), and long-term follow-ups (3-5 years) were included. Relative risk was used to pool the dichotomous outcomes using the random effects model employing the inverse variance method. All statistical analysis was conducted using Revman 5.4. Results: A total of 18 studies reporting data at different follow-ups for nine trials (n = 14319) were included. At short-term follow-up (<2 years), there were no significant differences between the two types of stents (all-cause death, cardiac death, Major adverse cardiovascular events (MACE), target vessel myocardial infarction, definite or probable stent thrombosis or safety outcomes (target vessel revascularization, target lesion revascularization, target vessel failure, target lesion failure). At intermediate follow-up (2-3 years), EES was superior to ZES for reducing target lesion revascularization (RR = 1.28, 95% CI = 1.05-1.58, p < 0.05). At long-term follow-up (3-5 years), there were no significant differences between the two groups for any of the pooled outcomes (p > 0.05). Conclusion: ZES and EES have similar safety and efficacy at short, intermediate, and long-term follow-ups.
引用
收藏
页数:14
相关论文
共 51 条
[1]  
[Anonymous], COCHRANE HDB SYSTEMA
[2]   Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis [J].
Bangalore, Sripal ;
Toklu, Bora ;
Amoroso, Nicholas ;
Fusaro, Mario ;
Kumar, Sunil ;
Hannan, Edward L. ;
Faxon, David P. ;
Feit, Frederick .
BMJ-BRITISH MEDICAL JOURNAL, 2013, 347
[3]   Cost-effectiveness of drug-eluting stents versus bare-metal stents in patients undergoing percutaneous coronary intervention [J].
Baschet, Louise ;
Bourguignon, Sandrine ;
Marque, Sebastien ;
Durand-Zaleski, Isabelle ;
Teiger, Emmanuel ;
Wilquin, Fanny ;
Levesque, Karine .
OPEN HEART, 2016, 3 (02)
[4]   OPERATING CHARACTERISTICS OF A BANK CORRELATION TEST FOR PUBLICATION BIAS [J].
BEGG, CB ;
MAZUMDAR, M .
BIOMETRICS, 1994, 50 (04) :1088-1101
[5]   Thin, Very Thin, or Ultrathin Strut Biodegradable or Durable Polymer-Coated Drug-Eluting Stents [J].
Buiten, Rosaly A. ;
Ploumen, Eline H. ;
Zocca, Paolo ;
Doggen, Carine J. M. ;
Danse, Peter W. ;
Schotborgh, Carl E. ;
Scholte, Martijn ;
van Houwelingen, K. Gert ;
Stoel, Martin G. ;
Hartmann, Marc ;
Gin, R. Melvyn Tjon Joe ;
Somi, Samer ;
Linssen, Gerard C. M. ;
Kok, Marlies M. ;
von Birgelen, Clemens .
JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (17) :1650-1660
[6]   Correlation of Intravascular Ultrasound Findings With Histopathological Analysis of Thrombus Aspirates in Patients With Very Late Drug-Eluting Stent Thrombosis [J].
Cook, Stephane ;
Ladich, Elena ;
Nakazawa, Gaku ;
Eshtehardi, Parham ;
Neidhart, Michel ;
Vogel, Rolf ;
Togni, Mario ;
Wenaweser, Peter ;
Billinger, Michael ;
Seiler, Christian ;
Gay, Steffen ;
Meier, Bernhard ;
Pichler, Werner J. ;
Jueni, Peter ;
Virmani, Renu ;
Windecker, Stephan .
CIRCULATION, 2009, 120 (05) :391-399
[7]   METAANALYSIS IN CLINICAL-TRIALS [J].
DERSIMONIAN, R ;
LAIRD, N .
CONTROLLED CLINICAL TRIALS, 1986, 7 (03) :177-188
[8]   Drug-eluting stents versus bare-metal stents for acute coronary syndrome [J].
Feinberg, Joshua ;
Nielsen, Emil Eik ;
Greenhalgh, Janette ;
Hounsome, Juliet ;
Sethi, Naqash J. ;
Safi, Sanam ;
Gluud, Christian ;
Jakobsen, Janus C. .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2017, (08)
[9]  
Grube Eberhard, 2004, Rev Cardiovasc Med, V5 Suppl 2, pS3
[10]   Safety and efficacy of everolimus-eluting stent versus zotarolimus-eluting stent: A meta-analysis of randomized controlled clinical trials and observational studies [J].
Gu, Hongqiu ;
Hua, Kun ;
Li, Wei ;
Wang, Yang ;
Yang, Jingan .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 201 :552-560