FLAIR: A Fast and Low-Redundancy Failure Recovery Framework for Inter Data Center Network

被引:1
|
作者
Zhang, Yuchao [1 ]
Huang, Haoqiang [1 ]
Abdelmoniem, Ahmed M. [2 ]
Zeng, Gaoxiong [3 ]
Zheng, Chenyue [1 ]
Que, Xirong [1 ]
Wang, Wendong [1 ]
Xu, Ke [4 ]
机构
[1] Beijing Univ Posts & Telecommun, Beijing 100876, Peoples R China
[2] Queen Mary Univ London, London E14NS, England
[3] Huawei Technol, Shenzhen 518129, Peoples R China
[4] Tsinghua Univ, Beijing 100190, Peoples R China
基金
中国国家自然科学基金;
关键词
Routing; Redundancy; Processor scheduling; Optimization; Delays; Network topology; Data centers; Inter data center network; failure recovery; routing optimization; ROUTING OPTIMIZATION;
D O I
10.1109/TCC.2024.3393735
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Due to the fast developments of 5G and IoT technologies, Inter-Datacenter (Inter-DC) networks are facing unprecedented pressure to duplicate large volumes of geographically distributed user data in a real-time manner. Meanwhile, with the expansion of Inter-DC networks scale, link/node failures also become increasingly frequent, negatively affecting the data transmission efficiency. Therefore, link failure recovery methods become of utmost importance. Many works investigated fast failure recovery, yet none of them consider the deployment overhead of such recovery schemes. While in this article, we found that the side-effect of deploying recovery strategies and the future availability of the recovered transmissions are also crucial for fast recovery. So we propose a fast and low-redundancy failure recovery framework, FLAIR, which consists of a fast recovery strategy FRAVaR and a redundancy removal algorithm ROSE. FRAVaR takes full consideration of deployment overhead by minimizing shuffle traffic. On its base, ROSE regularly eliminates the cumulative rerouting redundancy by removing unnecessary routing updates. The experiment results on 4 realistic network topologies show that FLAIR successfully reduces up to 48.2% deployment overhead compared with the state-of-the-art solutions, and thus reduces up to 70.2% recovery speed and improves up to 36% network utilization.
引用
收藏
页码:737 / 749
页数:13
相关论文
共 22 条
  • [21] Assessment of Low Global Warming Potential Refrigerants for Waste Heat Recovery in Data Center with On-Chip Two-Phase Cooling Loop
    Zhao, Yuming
    Wang, Jing
    Sun, Bin
    Wang, Zhenshang
    Li, Huashan
    Chen, Jiongcong
    FRONTIERS IN HEAT AND MASS TRANSFER, 2024, 22 (04): : 1171 - 1188
  • [22] A techno-economic evaluation of low global warming potential heat pump assisted organic Rankine cycle systems for data center waste heat recovery
    Marshall, Z. M.
    Duquette, J.
    ENERGY, 2022, 242