A High-Resolution Magnetic Field Imaging System Based on the Unpackaged Hall Element Array

被引:0
|
作者
Cai, Jiangwei [1 ]
Zhou, Tan [1 ]
Xu, Yishen [1 ,2 ]
Zhu, Xin [1 ,3 ]
机构
[1] Soochow Univ, Sch Optoelect Sci & Engn, Suzhou 215000, Peoples R China
[2] Suzhou City Univ, Sch Opt & Elect Informat, Suzhou 215104, Peoples R China
[3] Suzhou Matrix Semicond Ltd, Suzhou 215000, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 13期
关键词
high-resolution; magnetic field imaging system; unpackaged; sensitivity; Hall element; Hall linear array; X-Y axis motorized rail; wireless charging coil; SENSOR ARRAY;
D O I
10.3390/app14135788
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
We have designed a high-resolution magnetic field imaging system using 256 unpackaged Hall elements. These unpackaged Hall elements are arranged in a Hall linear array, and the distance between adjacent elements reaches 255 mu m. The sensitivity of the unpackaged Hall element array can be adjusted using a computer to measure magnetic environments with different magnetic field strengths. High-resolution magnetic field images of 256 x 256 pixels can be generated by moving the array using the X-Y axis motorized rail. This spatial resolution can reach 99.61 pixels per inch (ppi). This rail allows for the spatial resolution of the system to be further increased to 199.22 ppi by using a special movement route. In the experiments, we employ this system to image magnetized metal scissors, and the result displays the structural features of the scissor surface. We also detected the magnetic suction wireless charging coil inside an Apple phone. The image obtained shows the shape of the coil and the gap between the magnets. The high-resolution magnetic imaging system displays the magnetic characteristics of the sample very well and easily obtains information about small-shaped structures and defects on the sample surface. This provides the system with potential in several fields such as quality inspection, security, biomedicine, and detection imaging.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Dielectric nanohole array metasurface for high-resolution near-field sensing and imaging
    Conteduca, Donato
    Barth, Isabel
    Pitruzzello, Giampaolo
    Reardon, Christopher P.
    Martins, Emiliano R.
    Krauss, Thomas F.
    NATURE COMMUNICATIONS, 2021, 12 (01)
  • [32] High-resolution light field reconstruction using a hybrid imaging system
    Wang, Xiang
    Li, Lin
    Hou, Guangqi
    APPLIED OPTICS, 2016, 55 (10) : 2580 - 2593
  • [33] High-resolution imaging of the musculoskeletal system
    Erickson, SJ
    RADIOLOGY, 1997, 205 (03) : 593 - 618
  • [34] A system for high-resolution zooplankton imaging
    Samson, S
    Hopkins, T
    Remsen, A
    Langebrake, L
    Sutton, T
    Patten, J
    IEEE JOURNAL OF OCEANIC ENGINEERING, 2001, 26 (04) : 671 - 676
  • [35] A high-resolution fluid imaging system
    Lindsay, S
    Zhu, J
    Hudson, J
    AMERICAN LABORATORY, 1997, 29 (22) : 15 - &
  • [36] Deconvolution of High-Resolution Magnetic Field Scans for Improved Current Density Imaging
    Hoelzl, Patrick Alexander
    Zagar, Bernhard G.
    IEEE TRANSACTIONS ON MAGNETICS, 2014, 50 (02) : 101 - 104
  • [37] Demagnifying high-resolution imaging based on a new system for nanolithography
    Meng, Qingqing
    Zhang, Xiaoping
    Cheng, Lin
    Cao, Pengfei
    Li, Yuee
    Jin, Xin
    OPTICS COMMUNICATIONS, 2011, 284 (16-17) : 3891 - 3894
  • [38] Characterization of a sCMOS-based high-resolution imaging system
    Mittone, Alberto
    Manakov, Ilja
    Broche, Ludovic
    Jarnias, Christophe
    Coan, Paola
    Bravin, Alberto
    JOURNAL OF SYNCHROTRON RADIATION, 2017, 24 : 1226 - 1236
  • [39] High-resolution magnetic resonance instant imaging
    Emid, S.
    PHYSICA B-CONDENSED MATTER, 2007, 398 (01) : 38 - 39
  • [40] HIGH-RESOLUTION MAGNETIC IMAGING BY FORCE MICROSCOPY
    WICKRAMASINGHE, HK
    MARTIN, Y
    JOURNAL OF APPLIED PHYSICS, 1988, 63 (08) : 2948 - 2948