Machine learning-based estimation of patient body weight from radiation dose metrics in computed tomography

被引:0
作者
Ichikawa, Hajime [1 ,2 ]
Ichikawa, Shota [3 ,4 ]
Sawane, Yasuhiro [1 ]
机构
[1] Toyohashi Municipal Hosp, Dept Radiol, Toyohashi, Aichi, Japan
[2] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Dept Quantum Med Technol, Kanazawa, Ishikawa, Japan
[3] Niigata Univ, Fac Med, Sch Hlth Sci, Dept Radiol Technol, 2?746 Asahimachi Dori,Chuo Ku, Niigata 9518518, Japan
[4] Niigata Univ, Inst Res Adm, Niigata, Japan
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2024年 / 25卷 / 09期
关键词
body weight estimation; computed tomography; dose metrics; machine learning; radiation dose management; CT; SELECTION;
D O I
10.1002/acm2.14467
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeCurrently, precise patient body weight (BW) at the time of diagnostic imaging cannot always be used for radiation dose management. Various methods have been explored to address this issue, including the application of deep learning to medical imaging and BW estimation using scan parameters. This study develops and evaluates machine learning-based BW prediction models using 11 features related to radiation dose obtained from computed tomography (CT) scans.MethodsA dataset was obtained from 3996 patients who underwent positron emission tomography CT scans, and training and test sets were established. Dose metrics and descriptive data were automatically calculated from the CT images or obtained from Digital Imaging and Communications in Medicine metadata. Seven machine-learning models and three simple regression models were employed to predict BW using features such as effective diameter (ED), water equivalent diameter (WED), and mean milliampere-seconds. The mean absolute error (MAE) and correlation coefficient between the estimated BW and the actual BW obtained from each BW prediction model were calculated.ResultsOur results found that the highest accuracy was obtained using a light gradient-boosting machine model, which had an MAE of 1.99 kg and a strong positive correlation between estimated and actual BW (rho = 0.972). The model demonstrated significant predictive power, with 73% of patients falling within a +/- 5% error range. WED emerged as the most relevant dose metric for BW estimation, followed by ED and sex.ConclusionsThe proposed machine-learning approach is superior to existing methods, with high accuracy and applicability to radiation dose management. The model's reliance on universal dose metrics that are accessible through radiation dose management software enhances its practicality. In conclusion, this study presents a robust approach for BW estimation based on CT imaging that can potentially improve radiation dose management practices in clinical settings.
引用
收藏
页数:8
相关论文
共 31 条
  • [1] The accuracy of visual estimation of body weight in the ED
    Anglemyer, BL
    Hernandez, C
    Brice, JH
    Zou, B
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2004, 22 (07) : 526 - 529
  • [2] SmcHD1, containing a structural-maintenance-of-chromosomes hinge domain, has a critical role in X inactivation
    Blewitt, Marnie E.
    Gendrel, Anne-Valerie
    Pang, Zhenyi
    Sparrow, Duncan B.
    Whitelaw, Nadia
    Craig, Jeffrey M.
    Apedaile, Anwyn
    Hilton, Douglas J.
    Dunwoodie, Sally L.
    Brockdorff, Neil
    Kay, Graham F.
    Whitelaw, Emma
    [J]. NATURE GENETICS, 2008, 40 (05) : 663 - 669
  • [3] Random forests
    Breiman, L
    [J]. MACHINE LEARNING, 2001, 45 (01) : 5 - 32
  • [4] Size-specific Dose Estimates for Adult Patients at CT of the Torso
    Christner, Jodie A.
    Braun, Natalie N.
    Jacobsen, Megan C.
    Carter, Rickey E.
    Kofler, James M.
    McCollough, Cynthia H.
    [J]. RADIOLOGY, 2012, 265 (03) : 841 - 847
  • [5] Establishing how patient size and degree of miscentring affect CTDIvol, using patient data from a dose tracking system
    Cournane, Sean
    Brunell, Eimear
    Rowan, Michael
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1099)
  • [6] Determining body height and weight from thoracic and abdominal CT localizers in pediatric and young adult patients using deep learning
    Demircioglu, Aydin
    Quinsten, Anton S.
    Umutlu, Lale
    Forsting, Michael
    Nassenstein, Kai
    Bos, Denise
    [J]. SCIENTIFIC REPORTS, 2023, 13 (01)
  • [7] Imaging in forensic radiology: an illustrated guide for postmortem computed tomography technique and protocols
    Flach, Patricia M.
    Gascho, Dominic
    Schweitzer, Wolf
    Ruder, Thomas D.
    Berger, Nicole
    Ross, Steffen G.
    Thali, Michael J.
    Ampanozi, Garyfalia
    [J]. FORENSIC SCIENCE MEDICINE AND PATHOLOGY, 2014, 10 (04) : 583 - 606
  • [8] CT dose management of adult patients with unknown body weight using an effective diameter
    Fukunaga, Masaaki
    Matsubara, Kosuke
    Ichikawa, Shota
    Mitsui, Hideki
    Yamamoto, Hiroyuki
    Miyati, Tosiaki
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2021, 135
  • [9] A new method for estimating patient body weight using CT dose modulation data
    Gascho D.
    Ganzoni L.
    Kolly P.
    Zoelch N.
    Hatch G.M.
    Thali M.J.
    Ruder T.D.
    [J]. European Radiology Experimental, 1 (1)
  • [10] Determination of height, weight, body mass index, and body surface area with a single abdominal CT image
    Geraghty, EM
    Boone, JM