Evaluation of patients' Body Mass Index and weight as a simpler alternative method for calculating size-specific dose estimation in patients with lung computed tomography

被引:0
作者
Azinkhah, I. [1 ,2 ]
Sadeghi, M. [1 ,2 ]
机构
[1] Iran Univ Med Sci, Fintech Med Res Ctr, Tehran, Iran
[2] Iran Univ Med Sci, Sch Med, Med Phys Dept, Tehran, Iran
来源
INTERNATIONAL JOURNAL OF RADIATION RESEARCH | 2024年 / 22卷 / 02期
关键词
size-specific dose estimate; CT scan; patient's BMI; body diameter; ATTENUATION-BASED ESTIMATION; CT IMAGES; PURPOSE; METRICS; CHEST; RISK;
D O I
10.61186/ijrr.22.2.257
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background : Evaluation of Size-Specific Dose Estimation (SSDE) by patient's weight and Body Mass Index (BMI) instead of Anterior-Posterior (AP) and Lateral (LAT) diameter measurements in patient's images for lung computed tomography (CT). Materials and Methods: Before the examination, the weight and BMI of all patients were measured and calculated. All AP and LAT diameters were measured from the axial images, and localizer and conversion factors (f(size)) were calculated based on them. Volume Computed Tomography Dose Index (CTDIvol) and Dose Length Product (DLP) values were also recorded from the patient's examination summary. In this way, different SSDEs based on effective diameter (SSDEeff), water equivalent diameter (SSDEw), AP diameter (SSDEAP), LAT diameter (SSDELAT), sum of the AP and LAT diameters (SSDEAP+LAT), AP diameter in scout view (SSDEAPscout ) and LAT diameter in scout view (SSDELATscout ) are obtained. By Pearson statistical test the correlation between patients' BMI and weight with all types of SSDE calculation methods was examined. Results: There was a statistically significant correlation between all measured and compared parameters, but the most correlation between BMI and weight with SSDEs was obtained with SSDEeff (R=0.825, P<0.05) and SSDEw (R=0.777, P<0.05), respectively. Also, the correlation between BMI and effective diameter (d(eff )) (R=0913, P<0.05) is the highest among all types of diameters measured. The correlation of BMI with SSDEw and water equivalent diameter (d(w) ) was (R=0.807, P<0.05), (R=0.909, P<0.05), respectively. Conclusion: There seems to be a significant correlation between BMI andf_size so that we can estimate patients' SSDE without measuring AP and LAT diameters, even before a CT scan.
引用
收藏
页码:257 / 264
页数:8
相关论文
共 31 条
  • [1] AAPM, 2011, AAPM Rep, V204, P1
  • [2] Correlation of size-dependent conversion factor and body-mass-index using size-specific dose estimates formalism in CT examinations
    Alikhani, Babak
    Getzin, Tobias
    Kaireit, Till Frederik
    Ringe, Kristina Imeen
    Jamali, Leila
    Wacker, Frank
    Werncke, Thomas
    Raatschen, Hans-Juergen
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2018, 100 : 130 - 134
  • [3] [Anonymous], IEC 62271-200:2021 | IEC Webstore
  • [4] Institutional computed tomography diagnostic reference levels based on water-equivalent diameter and size-specific dose estimates
    Boos, Johannes
    Thomas, Christoph
    Appel, Elisabeth
    Klosterkemper, Yan
    Schleich, Christoph
    Aissa, Joel
    Bethge, Oliver Th
    Antoch, Gerald
    Kroepil, Patric
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (02) : 536 - 548
  • [5] ACCURACY OF SIZE-SPECIFIC DOSE ESTIMATE CALCULATION FROM CENTER SLICE IN COMPUTED TOMOGRAPHY
    Boos, Johannes
    Kroepil, Patric
    Bethge, Oliver Th.
    Aissa, Joel
    Schleich, Christoph
    Sawicki, Lino Morris
    Heinzler, Niklas
    Antoch, Gerald
    Thomas, Christoph
    [J]. RADIATION PROTECTION DOSIMETRY, 2018, 178 (01) : 8 - 19
  • [6] Does body mass index outperform body weight as a surrogate parameter in the calculation of size-specific dose estimates in adult body CT?
    Boos, Johannes
    Lanzman, Rotem S.
    Heusch, Philipp
    Aissa, Joel
    Schleich, Christoph
    Thomas, Christoph
    Sawicki, Lino M.
    Antoch, Gerald
    Kroepil, Patric
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1059)
  • [7] Attenuation-based size metric for estimating organ dose to patients undergoing tube current modulated CT exams
    Bostani, Maryam
    McMillan, Kyle
    Lu, Peiyun
    Kim, Hyun J.
    Cagnon, Chris H.
    DeMarco, John J.
    McNitt-Gray, Michael F.
    [J]. MEDICAL PHYSICS, 2015, 42 (02) : 958 - 968
  • [8] CT dose management of adult patients with unknown body weight using an effective diameter
    Fukunaga, Masaaki
    Matsubara, Kosuke
    Ichikawa, Shota
    Mitsui, Hideki
    Yamamoto, Hiroyuki
    Miyati, Tosiaki
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2021, 135
  • [9] Estimating Patient Dose from X-ray Tube Output Metrics: Automated Measurement of Patient Size from CT Images Enables Large-scale Size-specific Dose Estimates
    Ikuta, Ichiro
    Warden, Graham I.
    Andriole, Katherine P.
    Khorasani, Ramin
    Sodickson, Aaron
    [J]. RADIOLOGY, 2014, 270 (02) : 472 - 480
  • [10] SIMPLE METHOD OF SIZE-SPECIFIC DOSE ESTIMATES CALCULATION FROM PATIENT WEIGHT ON COMPUTED TOMOGRAPHY
    Iriuchijima, Akiko
    Fukushima, Yasuhiro
    Nakajima, Takahito
    Tsushima, Yoshito
    Ogura, Akio
    [J]. RADIATION PROTECTION DOSIMETRY, 2018, 178 (02) : 208 - 212