Association between dryness sensation and ocular surface temperature and conjunctival blood flow in soft contact lens wearers

被引:0
作者
Itokawa, Takashi [1 ]
Okajima, Yukinobu [1 ,2 ]
Iwashita, Hiroko [1 ]
Koji, Kakisu [1 ]
Tashiro, Shigeki [3 ]
Suzuki, Takashi [1 ,4 ]
Hori, Yuichi [1 ]
机构
[1] Toho Univ, Dept Ophthalmol, Grad Sch Med, 6-11-1 Omori Nishi,Ota Ku, Tokyo 1438541, Japan
[2] Tsunashima Eye Clin, Yokohama, Kanagawa, Japan
[3] Nagasaki Univ Hosp, Clin Res Ctr, Nagasaki, Japan
[4] Ishizuchi Eye Clin, Niihama, Ehime, Japan
关键词
Ocular surface temperature; Tear film stability; Conjunctival blood flow; Soft contact lens; Water gradient technology; TFOS INTERNATIONAL WORKSHOP; TEAR FILM STABILITY; DEFICIENT DRY EYES; DISCOMFORT REPORT; LASER SPECKLE; CORNEAL; SYMPTOMS; HYDROGEL; MENISCUS; MICROCIRCULATION;
D O I
10.1016/j.clae.2024.102166
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the association between dryness, ocular surface temperature (OST), and conjunctival blood flow (CBF) in soft contact lens (SCL) wearers after airflow stimulation. Methods: After recruiting 21 SCL wearers (mean age, 25.3 +/- 4.2 years), subjects used two different daily disposable silicone hydrogel SCLs (narafilcon A and delefilcon A lenses). On three of four measurement days, excluding the first, OST, CBF, tear meniscus height (TMH), and non-invasive tear break-up time (NIBUT) were measured after airflow stimulation at a rate of 3 m/s for 10 min. The measurements were conducted without SCLs on the first and second days, and with different SCLs on the third and fourth days. Dryness was evaluated using the visual analogue scale (VAS). These parameters were compared between the two types of SCLs, and their association with the dryness sensation was then investigated. Results: Dryness was significantly weakly correlated with OST (r = -0.375, p < 0.05) and CBF (r = 0.339, p < 0.05). TMH, NIBUT, and VAS scores for dryness with the delefilcon A lens (0.15 +/- 0.05 mm, 3.7 +/- 01.7 s and 29.4 +/- 16.9) were significantly higher, longer, and lower, respectively, than those with the narafilcon A lens (0.12 +/- 0.05 mm, 2.3 +/- 1.7 s and 35.9 +/- 17.0; p < 0.05, p < 0.01 and p < 0.01). The changes in the OST and CBF between with and without the delefilcon A lens (-0.36 +/- 0.35 degrees C and 0.99 +/- 0.19) were significantly small compared to the narafilcon A lens (-0.60 +/- 0.42 degrees C and 1.11 +/- 0.21; p < 0.01 for both comparisons). Conclusion: Dryness was correlated with OST and CBF, which indicates that when dryness was high, OST was low and CBF was high. These results suggest that OST and CBF assessments are effective for evaluating dryness sensation.
引用
收藏
页数:7
相关论文
共 51 条
[1]  
Abreau K, 2016, OCUL SURF, V14, P64, DOI 10.1016/j.jtos.2015.09.001
[2]   Laser Speckle and Hydrogen Gas Clearance Measurements of Optic Nerve Circulation in Albino and Pigmented Rabbits With or Without Optic Disc Atrophy [J].
Aizawa, Naoko ;
Nitta, Fumihiko ;
Kunikata, Hiroshi ;
Sugiyama, Tetsuya ;
Ikeda, Tsunehiko ;
Araie, Makoto ;
Nakazawa, Toru .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (12) :7991-7996
[3]   Assessment of lower tear meniscus measurements obtained with Keratograph and agreement with Fourier-domain optical-coherence tomography [J].
Arriola-Villalobos, Pedro ;
Ignacio Fernandez-Vigo, Jose ;
Diaz-Valle, David ;
Peraza-Nieves, Jorge E. ;
Fernandez-Perez, Cristina ;
Benitez-del-Castillo, Jose M. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2015, 99 (08) :1120-1125
[4]   Thermal fluctuation based study of aqueous deficient dry eyes by noninvasive thermal imaging [J].
Azharuddin, Mohammad ;
Bera, Sumanta Kr. ;
Datta, Himadri ;
Dasgupta, Anjan Kr. .
EXPERIMENTAL EYE RESEARCH, 2014, 120 :97-102
[5]   Conjunctival Vascular Adaptation Related to Ocular Comfort in Habitual Contact Lens Wearers [J].
Chen, Qi ;
Jiang, Hong ;
Wang, Jianhua .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 216 :99-109
[6]   Altered Bulbar Conjunctival Microcirculation in Response to Contact Lens Wear [J].
Chen, Wan ;
Xu, Zhe ;
Jiang, Hong ;
Zhou, Jin ;
Wang, Liang ;
Wang, Jianhua .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2017, 43 (02) :95-99
[7]   Assessment of corneal thickness and tear meniscus during contact-lens wear [J].
Del Aguila-Carrasco, Antonio J. ;
Ferrer-Blasco, Teresa ;
Garcia-Lazaro, Santiago ;
Esteve-Taboada, Jose J. ;
Montes-Mico, Robert .
CONTACT LENS & ANTERIOR EYE, 2015, 38 (03) :185-193
[8]   The TFOS International Workshop on Contact Lens Discomfort: Report of the Subcommittee on Epidemiology [J].
Dumbleton, Kathy ;
Caffery, Barbara ;
Dogru, Murat ;
Hickson-Curran, Sheila ;
Kern, Jami ;
Kojima, Takashi ;
Morgan, Philip B. ;
Purslow, Christine ;
Robertson, Danielle M. ;
Nelson, J. Daniel .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (11) :20-36
[9]   Impact of Air Exposure Time on the Water Contact Angles of Daily Disposable Silicone Hydrogels [J].
Eftimov, Petar ;
Yokoi, Norihiko ;
Peev, Nikola ;
Georgiev, Georgi As. .
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2019, 20 (06)
[10]   Inflammatory status predicts contact lens discomfort under adverse environmental conditions [J].
Fernandez, Itziar ;
Lopez-Miguel, Alberto ;
Martin-Montanez, Vicente ;
Enriquez-de-Salamanca, Amalia ;
Calonge, Margarita ;
Gonzalez-Meijome, Jose M. ;
Gonzalez-Garcia, Maria J. .
OCULAR SURFACE, 2020, 18 (04) :829-840