Assessment of Bitterness in Non-Charged Pharmaceuticals with a Taste Sensor: A Study on Substances with Xanthine Scaffold and Allopurinol

被引:2
作者
Zhao, Zeyu [1 ]
Song, Fang [1 ]
Kimura, Shunsuke [2 ,3 ,4 ]
Onodera, Takeshi [1 ]
Uchida, Takahiro [4 ,5 ]
Toko, Kiyoshi [2 ,4 ,6 ,7 ]
机构
[1] Kyushu Univ, Grad Sch Informat Sci & Elect Engn, 744 Motooka,Nishi Ku, Fukuoka 8190395, Japan
[2] Kyushu Univ, Res & Dev Ctr F Sense Devices, 744 Motooka,Nishi Ku, Fukuoka 8190395, Japan
[3] Nakamura Gakuen Univ, Fac Nutr Sci, 5-7-1 Befu,Jonan Ku, Fukuoka 8140198, Japan
[4] Nakamura Gakuen Univ, Food & Hlth Innovat Ctr, 5-7-1 Befu,Jonan Ku, Fukuoka 8140198, Japan
[5] Mukogawa Womens Univ, Fac Pharmaceut Sci, 11-68 Koshien 9-Bancho, Nishimiya 6638179, Japan
[6] Kyushu Univ, Inst Adv Study, 744 Motooka,Nishi Ku, Fukuoka 8190395, Japan
[7] Nakamura Gakuen Univ, Grad Sch Nutr Sci, 5-7-1 Befu,Jonan Ku, Fukuoka 8140198, Japan
关键词
taste sensor; allostery; xanthine derivatives; allopurinol; surface modification; WEBER-FECHNER LAW; 1,3,8-TRISUBSTITUTED PURINE-2,6-DIONES; H-1-RECEPTOR ANTAGONISTS; ELECTRONIC TONGUE; ORAL MEDICATIONS; PENTOXIFYLLINE; DESIGN; ANTIBIOTICS; DOXOFYLLINE; FORMULATION;
D O I
10.3390/molecules29112452
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Taste sensors with an allostery approach have been studied to detect non-charged bitter substances, such as xanthine derivatives, used in foods (e.g., caffeine) or pharmaceuticals (e.g., etofylline). In this study, the authors modified a taste sensor with 3-bromo-2,6-dihydroxybenzoic acid and used it in conjunction with sensory tests to assess the bitterness of non-charged pharmaceuticals with xanthine scaffolds (i.e., acefylline and doxofylline), as well as allopurinol, an analogue of hypoxanthine. The results show that the sensor was able to differentiate between different levels of sample bitterness. For instance, when assessing a 30 mM sample solution, the sensor response to acefylline was 34.24 mV, which corresponded to the highest level of bitterness (tau = 3.50), while the response to allopurinol was lowest at 2.72 mV, corresponding to relatively weaker bitterness (tau = 0.50). Additionally, this study extended the application of the sensor to detect pentoxifylline, an active pharmaceutical ingredient in pediatric medicines. These results underscore the taste sensor's value as an additional tool for early-stage assessment and prediction of bitterness in non-charged pharmaceuticals.
引用
收藏
页数:14
相关论文
共 68 条
[1]   The latest trends in the taste assessment of pharmaceuticals [J].
Anand, Vikas ;
Kataria, Mahesh ;
Kukkar, Vipin ;
Saharan, Vandana ;
Choudhury, Pratim Kumar .
DRUG DISCOVERY TODAY, 2007, 12 (5-6) :257-265
[2]   Prescribing for children - taste and palatability affect adherence to antibiotics: a review [J].
Baguley, Dave ;
Lim, Emma ;
Bevan, Amanda ;
Pallet, Ann ;
Faust, Saul N. .
ARCHIVES OF DISEASE IN CHILDHOOD, 2012, 97 (03) :293-297
[3]   Design and synthesis of novel xanthine derivatives as potent and selective A2B adenosine receptor antagonists for the treatment of chronic inflammatory airway diseases [J].
Basu, Sujay ;
Barawkar, Dinesh A. ;
Ramdas, Vidya ;
Patel, Meena ;
Waman, Yogesh ;
Panmand, Anil ;
Kumar, Santosh ;
Thorat, Sachin ;
Naykodi, Minakshi ;
Goswami, Arnab ;
Reddy, B. Srinivasa ;
Prasad, Vandna ;
Chaturvedi, Sandhya ;
Quraishi, Azfar ;
Menon, Suraj ;
Paliwal, Shalini ;
Kulkarni, Abhay ;
Karande, Vikas ;
Ghosh, Indraneel ;
Mustafa, Syed ;
De, Siddhartha ;
Jain, Vaibhav ;
Banerjee, Ena Ray ;
Rouduri, Sreekanth R. ;
Palle, Venkata P. ;
Chugh, Anita ;
Mookhtiar, Kasim A. .
EUROPEAN JOURNAL OF MEDICINAL CHEMISTRY, 2017, 134 :218-229
[4]   KINETICS OF INTRAVENOUS AND ORAL PENTOXIFYLLINE IN HEALTHY-SUBJECTS [J].
BEERMANN, B ;
INGS, R ;
MANSBY, J ;
CHAMBERLAIN, J ;
MCDONALD, A .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1985, 37 (01) :25-28
[5]   Pharmacokinetic and tolerability assessment of a pediatric oral formulation of pentoxifylline in Kawasaki disease [J].
Best, BM ;
Burns, JC ;
DeVincenzo, J ;
Phelps, SJ ;
Blumer, JL ;
Wilson, JT ;
Capparelli, EV ;
Connor, JD .
CURRENT THERAPEUTIC RESEARCH-CLINICAL AND EXPERIMENTAL, 2003, 64 (02) :96-115
[6]   NEUTRAL-CARRIER-BASED ION-SELECTIVE MICROELECTRODES DESIGN AND APPLICATION - A REVIEW [J].
BUHRER, T ;
GEHRIG, P ;
SIMON, W .
ANALYTICAL SCIENCES, 1988, 4 (06) :547-557
[7]   Fundamentals and application of voltammetric electronic tongues in quantitative analysis [J].
Ceto, Xavier ;
Perez, Sandra ;
Prieto-Simon, Beatriz .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2022, 157
[8]   Computational design of G Protein-Coupled Receptor allosteric signal transductions [J].
Chen, Kuang-Yui Michael ;
Keri, Daniel ;
Barth, Patrick .
NATURE CHEMICAL BIOLOGY, 2020, 16 (01) :77-+
[9]   Recent advances in bitterness evaluation methods [J].
Chen, Zhaobin ;
Wu, Jinhui ;
Zhao, Yang ;
Xu, Feng ;
Hu, Yiqiao .
ANALYTICAL METHODS, 2012, 4 (03) :599-608
[10]   Colorimetric Sensor Array for White Wine Tasting [J].
Chung, Soo ;
Park, Tu San ;
Park, Soo Hyun ;
Kim, Joon Yong ;
Park, Seongmin ;
Son, Daesik ;
Bae, Young Min ;
Cho, Seong In .
SENSORS, 2015, 15 (08) :18197-18208