Feasibility, safety, and patient acceptability of electronic inspiratory muscle training in patients who require prolonged mechanical ventilation in the intensive care unit: A dual-centre observational study

被引:5
作者
Nickels, Marc [1 ,4 ]
Erwin, Katie [2 ]
McMurray, Grant [3 ]
Talbot, Richie [4 ]
Strong, Mark [3 ]
Krishnan, Anand [5 ]
van Haren, Frank M. P. [6 ,7 ]
Bissett, Bernie [2 ,4 ]
机构
[1] Ipswich Hosp, Dept Physiotherapy, Brisbane, Australia
[2] Canberra Hosp, Physiotherapy Dept, Garran, Australia
[3] Princess Alexandra Hosp, Physiotherapy Dept, Brisbane, Australia
[4] Univ Canberra, Discipline Physiotherapy, Off 8,Level 2,Guraguma St, Bruce, ACT 2617, Australia
[5] Princess Alexandra Hosp, Intens Care Unit, Brisbane, Australia
[6] St George Hosp, Intens Care Unit, Sydney, Australia
[7] Australian Natl Univ, Coll Hlth & Med, Canberra, Australia
关键词
Physiotherapy (techniques); Breathing exercises; Intensive care; Critical care; Mechanical ventilation; REHABILITATION; INTERVENTIONS; MOBILIZATION;
D O I
10.1016/j.aucc.2023.04.008
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Inspiratory muscle training (IMT) is an intervention that can be used to rehabilitate the respiratory muscle deconditioning experienced by patients with critical illness, requiring prolonged mechanical ventilation. Clinicians are currently using mechanical threshold IMT devices that have limited resistance ranges. Objectives: The objective of this study was to evaluate the safety, feasibility, and acceptability of using an electronic device to facilitate IMT with participants requiring prolonged mechanical ventilation. Method: A dual -centre observational cohort study, with convenience sampling, was conducted at two tertiary intensive care units. Daily training supervised by intensive care unit physiotherapists was completed with the electronic IMT device. A priori definitions for feasibility, safety, and acceptability were determined. Feasibility was defined as more than 80% of planned sessions completed. Safety was defined as no major adverse events and less than 3% minor adverse event rate, and acceptability was evaluated following the acceptability of intervention framework principles. Results: Forty participants completed 197 electronic IMT treatment sessions. Electronic IMT was feasible, with 81% of planned sessions completed. There were 10% minor adverse events and no major adverse events. All the minor adverse events were transient without clinical consequences. All the participants who recalled completing electronic IMT sessions reported that the training was acceptable. Acceptability was demonstrated; over 85% of participants reported that electronic IMT was either helpful or beneficial and that electronic IMT assisted their recovery. Conclusion: Electronic IMT is feasible and acceptable to complete with critically ill participants who require prolonged mechanical ventilation. As all minor adverse events were transient without clinical consequences, electronic IMT can be considered a relatively safe intervention with patients who require prolonged mechanical ventilation. (c) 2023 Australian College of Critical Care Nurses Ltd. Published by Elsevier Ltd. This is an open access article under the CC BY -NC -ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:448 / 454
页数:7
相关论文
共 26 条
[1]   Inspiratory muscle training for recovered COVID-19 patients after weaning from mechanical ventilation A pilot control clinical study [J].
Abodonya, Ahmed M. ;
Abdelbasset, Walid Kamal ;
Awad, Elsayed A. ;
Elalfy, Ibrahim E. ;
Salem, Hosni A. ;
Elsayed, Shereen H. .
MEDICINE, 2021, 100 (13) :E25339
[2]  
[Anonymous], 2017, Declined Detainer Outcome Report
[3]   Safety and Feasibility of an Exercise Prescription Approach to Rehabilitation Across the Continuum of Care for Survivors of Critical Illness [J].
Berney, Sue ;
Haines, Kimberley ;
Skinner, Elizabeth H. ;
Denehy, Linda .
PHYSICAL THERAPY, 2012, 92 (12) :1524-1535
[4]   Respiratory Muscle Rehabilitation in Patients with Prolonged Mechanical Ventilation: A Targeted Approach [J].
Bissett, Bernie ;
Gosselink, Rik ;
van Haren, Frank M. P. .
CRITICAL CARE, 2020, 24 (01)
[5]   Inspiratory muscle training for intensive care patients: A multidisciplinary practical guide for clinicians [J].
Bissett, Bernie ;
Leditschke, I. Anne ;
Green, Margot ;
Marzano, Vince ;
Collins, Sarajane ;
Van Haren, Frank .
AUSTRALIAN CRITICAL CARE, 2019, 32 (03) :249-255
[6]  
Bissett Bernie, 2012, Intensive Crit Care Nurs, V28, P98, DOI 10.1016/j.iccn.2012.01.003
[7]   Weaned but weary: One third of adult intensive care patients mechanically ventilated for 7 days or more have impaired inspiratory muscle endurance after successful weaning [J].
Bissett, Bernie ;
Leditschke, I. Anne ;
Neeman, Teresa ;
Boots, Robert ;
Paratz, Jennifer .
HEART & LUNG, 2014, 44 (01) :15-20
[8]   Does mechanical threshold inspiratory muscle training promote recovery and improve outcomes in patients who are ventilator-dependent in the intensive care unit? The IMPROVE randomised trial [J].
Bissett, Bernie M. ;
Leditschke, I. Anne ;
Neeman, Teresa ;
Green, Margot ;
Marzano, Vince ;
Erwin, Katie ;
van Haren, Frank MP. ;
Boots, Robert ;
Paratz, Jennifer .
AUSTRALIAN CRITICAL CARE, 2023, 36 (04) :613-621
[9]   Inspiratory muscle training to enhance recovery from mechanical ventilation: a randomised trial [J].
Bissett, Bernie M. ;
Leditschke, I. Anne ;
Neeman, Teresa ;
Boots, Robert ;
Paratz, Jennifer .
THORAX, 2016, 71 (09) :812-819
[10]   Cognitive and psychosocial outcomes of mechanically ventilated intensive care patients with and without delirium [J].
Bulic, Daniella ;
Bennett, Michael ;
Georgousopoulou, Ekavi N. ;
Shehabi, Yahya ;
Tai Pham ;
Looi, Jeffrey C. L. ;
van Haren, Frank M. P. .
ANNALS OF INTENSIVE CARE, 2020, 10 (01)