MICROSCOPE EVALUATION OF MICRO-GAPS AT IMPLANT-ABUTMENT CONNECTION

被引:1
|
作者
Tartea, Daniel Adrian [1 ]
Popescu, Sanda Mihaela [2 ]
Manolea, Horia Octavian [3 ]
Ionescu, Mihaela [4 ]
Amarascu, Olimpia Marina [5 ]
Marasescu, Petre Costin [6 ]
Gingu, Oana [7 ]
机构
[1] Univ Med & Pharm Craiova, Craiova, Romania
[2] Univ Med & Pharm Craiova, Fac Dent Med, Dept Oral Rehabil, Craiova, Romania
[3] Univ Med & Pharm Craiova, Fac Dent Med, Dept Dent Mat, Craiova, Romania
[4] Univ Med & Pharm Craiova, Fac Dent Med, Dept Med Informat & Biostat, Craiova, Romania
[5] Univ Med & Pharm Craiova, Fac Dent Med, Dept Dent Morphol, Craiova, Romania
[6] Univ Med & Pharm Craiova, Fac Dent Med, Dept Dent Technol, Craiova, Romania
[7] Univ Craiova, Fac Mech, Dept Engn & Management Technol Syst, Craiova, Romania
来源
关键词
dental implant custom abutments; CAD/CAM; dental technology; micro-gap; implant-abutment interface; vertical fit; IN-VITRO EVALUATION; INTERNAL HEXAGON; DENTAL IMPLANTS; ZIRCONIA; TITANIUM; FIT; ACCURACY;
D O I
10.6261/RJOR.2024.2.16.36
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The use of custom CAD/CAM abutments in implant restorations has become a reality, but there are questions about the existence of micro-gaps at the implant-abutment junction larger than those of the original standard stock abutments. The purpose of this study was to compare dimensions of the micro-gaps between four types of implant abutments (original dental implant stock abutments, compatible dental implant stock abutments, and two types of customized CAD/CAM dental implant abutments) all with the same connection of Bredent Sky system mounted on a standard implant. Material and Method: Micro-gap measurements were made on four groups of Titanium abutments: 1) original dental implant stock abutments - industrial machined, 2) compatible dental implant stock abutments - industrial machined and 3) and 4) compatible customized CAD/CAM dental implant abutments - non-industrial milled with two different parameters in hyperDENT CAM software and Paragon Tools. The Nikon SMZ745T stereomicroscope was used to measure the micro-gaps of each dental implant abutment and results were statistically analyzed. Results: The micro-gaps measured on implant-abutments junction did not show significant differences between original abutment, and the three types of compatible abutments. Conclusions: No significant differences of the micro-gap at the implant-abutment junction were observed between the original implant abutments and compatible abutments, and customized abutments. Micro-gap dimensions were within the clinically accepted limit and the use of custom CAD/CAM dental implant abutments is reliable .
引用
收藏
页码:411 / 423
页数:13
相关论文
共 50 条
  • [21] The influence of prosthetic crown height and implant-abutment connection design selection on the long-term implant-abutment stability: A laboratory study
    Bagegni, Aimen
    Spies, Benedikt C.
    Kern, Matthias
    Hazard, Derek
    Kohal, Ralf
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 113
  • [22] Radiographical Evaluation of the Gap at the Implant-Abutment Interface
    Papavassiliou, Harris
    Kourtis, Stefanos
    Katerelou, Julia
    Chronopoulos, Vasillios
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2010, 22 (04) : 235 - 250
  • [23] Influence of Abutment Fabrication Method on 3D Fit at the Implant-Abutment Connection
    Ramalho, Ilana
    Witek, Lukasz
    Coelho, Paulo G.
    Bergamo, Edmara
    Pegoraro, Luiz Fernando
    Bonfante, Estevam A.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2020, 33 (06) : 641 - 647
  • [24] The influence of prosthetic crown height and implant-abutment connection design selection on the long-term implant-abutment stability: A laboratory study
    Bagegni, Aimen
    Spies, Benedikt C.
    Kern, Matthias
    Hazard, Derek
    Kohal, Ralf
    Journal of the Mechanical Behavior of Biomedical Materials, 2021, 113
  • [25] Molecular leakage at implant-abutment connection-in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration
    Harder, Soenke
    Dimaczek, Birka
    Acil, Yaha
    Terheyden, Hendrik
    Freitag-Wolf, Sandra
    Kern, Matthias
    CLINICAL ORAL INVESTIGATIONS, 2010, 14 (04) : 427 - 432
  • [26] 3D EVALUATION OF MICROGAPS AT THE IMPLANT-ABUTMENT CONNECTION BEFORE AND AFTER THERMODYNAMIC CYCLING
    Cetin, Tugce
    Asian, Y. Umut
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2024, 37 (03) : e99 - e111
  • [27] Fatigue Failure of Narrow Implants with Different Implant-Abutment Connection Designs
    Bordin, Dimorvan
    Witek, Lukasz
    Fardin, Vinicius P.
    Bonfante, Estevam A.
    Coelho, Paulo G.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (07): : 659 - 664
  • [28] In vitro assessment of connection strength and stability of internal implant-abutment connections
    Kofron, Michelle D.
    Carstens, Matthew
    Fu, Cong
    Wen, Hai Bo
    CLINICAL BIOMECHANICS, 2019, 65 : 92 - 99
  • [29] Implant-Abutment Connection Deformation After Prosthetic Procedures: An In Vitro Study
    Micarelli, Costanza
    Canullo, Luigi
    Iannello, Giuliano
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2015, 28 (03) : 282 - 286
  • [30] Bacterial Leakage and Microgap along Implant-Abutment Connection in Three Different Implant Systems
    Bajoghli, Farshad
    Amjadi, Mehrak
    Akouchekian, Mohadese
    Narimani, Tahmineh
    INTERNATIONAL JOURNAL OF ADVANCED BIOTECHNOLOGY AND RESEARCH, 2016, 7 (04): : 1284 - 1290