Additive Manufacturing Titanium Dental Implants Placed in Sinuses Grafted with 70HA:30-TCP: A One-Year Retrospective Study for Evaluation of Survival Rate

被引:1
|
作者
Mafra, Ilton Jose [1 ]
Bordin, Dimorvan [1 ]
Siroma, Rafael S. [1 ]
Moraschini, Vittorio [2 ]
Faverani, Leonardo P. [3 ]
Souza, Joao Gabriel [1 ]
Mourao, Carlos Fernando [4 ]
Shibli, Jamil Awad [1 ]
机构
[1] Univ Guarulhos, Dept Periodontol, Dent Res Div, BR-07023070 Guarulhos, SP, Brazil
[2] Veiga Almeida Univ, Sch Dent, Dept Periodontol, Dent Res Div, Rua Ibituruna 108, BR-20271020 Rio De Janeiro, RJ, Brazil
[3] Sao Paulo State Univ UNESP, Sch Dent, Dept Diag & Surg, Div Oral & Maxillofacial Surg & Implantol, R Jose Bonifacio 1193, BR-16015050 Aracatuba, SP, Brazil
[4] Tufts Univ, Sch Dent Med, Dept Periodontol, Boston, MA 02111 USA
关键词
maxillary sinus augmentation; synthetic material; dental implants; bone substitutes; BONE; RISK;
D O I
10.3390/dj12060181
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The present short-term retrospective study evaluated the implant survival rate and peri-implant bone loss around additive-manufactured titanium implants placed in sinuses grafted with Plenum Osshp (Plenum Bioengenharia, Jundia, SP, Brazil) (70HA:30 beta-TCP) material. A total of 39 implants were inserted after 23 sinus floor elevation procedures in 16 consecutive patients. Prosthetic rehabilitation included fixed partial prostheses (three units), single crowns (eleven units), and fixed full arches (three units). Clinical and radiographic parameters of implant-supported restorations were evaluated after at least one year of occlusal loading. The implant-crown success criteria included the absence of pain, suppuration, and clinical mobility, an average distance between the implant shoulder and the first visible bone contact (DIB) < 1.0 mm from the initial surgery, and the absence of prosthetic complications at the implant-abutment interface. The overall cumulative implant survival rate was 97.43%. No prosthetic complications at the implant-abutment interface were reported. After one year, the mean DIB was 0.23 mm +/- 0.14. Within the limits of this retrospective study, it can be concluded that 70 HA:30 beta-TCP allowed stable and reliable bone support to maintain healthy conditions around titanium dental implants produced by additive manufacturing.
引用
收藏
页数:11
相关论文
共 4 条
  • [1] Impact of Implant Diameter on the Early Survival Rate of Dental Implants in the Saudi Population: A One-Year Retrospective Study
    Mously, Eihab A.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (04)
  • [2] One-Year Survival Rate Outcomes of Innovative Dental Implants: A Prospective Clinical Study
    Piek, Dana
    Livne, Shiri
    Harel, Noga
    Lerner, Henriette
    Palti, Ady
    Ormianer, Zeev
    IMPLANT DENTISTRY, 2013, 22 (06) : 572 - 577
  • [3] Ten-year Survival Rate of Cernent- and Screw-retained Restorations on Bone-level Dental Implants in Grafted and Non-grafted Sites: A Retrospective Study
    Alresheedi, Bandar Awadh
    Alazmi, Saad Obaid
    Almutairi, Faris Jaser
    ORAL HEALTH & PREVENTIVE DENTISTRY, 2021, 19 (01) : 517 - 522
  • [4] Evaluation of Survival and Success Rates of Dental Implants Placed at the Time of or After Alveolar Ridge Augmentation with an Autogenous Mandibular Bone Graft and Titanium Mesh: A 3- to 8-year Retrospective Study
    Corinaldesi, Giuseppe
    Pieri, Francesco
    Sapigni, Licia
    Marchetti, Claudio
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (06) : 1119 - 1128