Enhancement of buildings energy efficiency using passive PCM coupled with natural ventilation in the Moroccan climate zones

被引:5
作者
Salihi, Mustapha [1 ,2 ]
Chhiti, Younes [1 ,2 ]
El Fiti, Maryam [1 ,2 ]
Harmen, Yasser [1 ,2 ]
Chebak, Ahmed [1 ]
Jama, Charafeddine [3 ]
机构
[1] Mohammed VI Polytech Univ, Green Tech Inst GTI, Ben Guerir, Morocco
[2] Ibn Tofail Univ, Ecole Natl Super Chim, Lab Mat Avances Genie Procedes, Kenitra, Morocco
[3] Univ Lille, UMET Unite Mat & Transformat, Cent Lille, CNRS,INRAE,UMR 8207, F-59000 Lille, France
关键词
Natural ventilation; Thermal comfort; Energy efficiency; Phase Change Material (PCM); Hysteresis; PHASE-CHANGE MATERIALS; THERMAL INSULATION; PERFORMANCE; ENVELOPE; OPTIMIZATION; SIMULATION; DESIGN; IMPROVE;
D O I
10.1016/j.enbuild.2024.114322
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The integration of Phase Change Materials (PCMs) in building envelopes has gained significant attention in recent years as a promising solution for thermal energy storage. PCM technology utilizes the latent heat of a material to store and release large amounts of energy, making it an effective method for passive thermal regulation and stabilization of the indoor building temperatures. However, to fully exploit the potential of the PCM, it must be completely charged and discharged in each cycle. With this fact in mind, this work aims to assess the performance of the PCMs in Moroccan climate zones, as well as to find out the best combination of PCM and natural ventilation to enhance the overall cooling energy performance of buildings. To this end, a numerical investigation was conducted in a residential building located in six climate regions of Morocco. The EnergyPlus software with the integrated PCM hysteresis model was used. Firstly, the effect of the PCM phase change temperature throughout the year was evaluated considering six cities located in those climates. Subsequently, an analysis was conducted during the summer season, resulting in the identification of the optimal configuration regarding PCM phase change temperature and thickness for each city. Furthermore, various natural ventilation scenarios i.e. night and whole-day natural ventilation, were implemented to investigate their impact on the process of PCM charge-discharge cycle. The results reveal that the integration of natural ventilation in PCMenhanced building was an effective method that solidifies the PCM every required cycle. The integration of PCM with night natural ventilation (NNV) leads to improve the PCM activation by between 22.4% and 26.1%, in the warm and temperate Mediterranean climate. However, whole-day natural ventilation controlled (NVC) further decreases cooling energy consumption by 2-9% compared to NNV in all studied climates, making it the best combination.
引用
收藏
页数:23
相关论文
共 49 条
  • [1] Improving the energy efficiency of passive PCM system using controlled natural ventilation
    Prabhakar, Mohit
    Saffari, Mohammad
    de Gracia, Alvaro
    Cabeza, Luisa F.
    ENERGY AND BUILDINGS, 2020, 228 (228)
  • [2] Coupling PCM wallboard utilization with night Ventilation: Energy efficiency and overheating risk in office buildings under climate change impact
    Tamer, Tolga
    Dino, Ipek Gursel
    Baker, Derek K.
    Akgul, Cagla Meral
    ENERGY AND BUILDINGS, 2023, 298
  • [3] Controlled Natural Ventilation Coupled with Passive PCM System to Improve the Cooling Energy Performance in Office Buildings
    Saffari, Mohammad
    Prabhakar, Mohit
    de Gracia, Alvaro
    Mangina, Eleni
    Finn, Donal P.
    Cabeza, Luisa F.
    PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 1732 - 1739
  • [4] Optimal control of natural ventilation as passive cooling strategy for improving the energy performance of building envelope with PCM integration
    Piselli, Cristina
    Prabhakar, Mohit
    de Gracia, Alvaro
    Saffari, Mohammad
    Pisello, Anna Laura
    Cabeza, Luisa F.
    RENEWABLE ENERGY, 2020, 162 : 171 - 181
  • [5] Implementing natural ventilation and daylighting strategies for thermal comfort and energy efficiency in office buildings in Burkina Faso
    Zoure, Abraham Nathan
    Genovese, Paolo Vincenzo
    ENERGY REPORTS, 2023, 9 : 3319 - 3342
  • [6] The effect of atrium configurations on energy usage and natural ventilation in high-rise office buildings in Tehran climate
    Heydari, Meysam Daloe
    Ghanbaran, Abdulhamid
    Varmazyar, Mostafa
    INTERNATIONAL JOURNAL OF VENTILATION, 2024, 23 (01) : 1 - 24
  • [7] Assessment of Natural Ventilation Potential for Residential Buildings across Different Climate Zones in Australia
    Tan, Zijing
    Deng, Xiang
    ATMOSPHERE, 2017, 8 (09):
  • [8] INDOOR CLIMATE AND ENERGY CONSUMPTION IN BUILDINGS WITH NATURAL VENTILATION
    Nantka, Marian B.
    ARCHITECTURE CIVIL ENGINEERING ENVIRONMENT, 2008, 1 (03) : 107 - 118
  • [9] Review of passive PCM latent heat thermal energy storage systems towards buildings' energy efficiency
    Soares, N.
    Costa, J. J.
    Gaspar, A. R.
    Santos, P.
    ENERGY AND BUILDINGS, 2013, 59 : 82 - 103
  • [10] Impact of climate change on energy saving potentials of natural ventilation and ceiling fans in mixed-mode buildings
    Bamdad, Keivan
    Matour, Soha
    Izadyar, Nima
    Omrani, Sara
    BUILDING AND ENVIRONMENT, 2022, 209