Development and validation of a liquid chromatography-mass spectrometry method for quantification of octadecylamine in the secondary circuit of a nuclear power plant in the presence of other amines

被引:5
作者
Bosco Ackerman, Bettina [1 ]
Martin, Silvana [2 ]
Espinosa, Mariela [2 ]
Chocron, Mauricio [1 ]
Babay, Paola Alejandra [2 ]
机构
[1] Natl Commiss Atom Energy, Dept Chem & Proc Nucl Facil, Buenos Aires, Argentina
[2] Natl Commiss Atom Energy, Dept Analyt Chem, Av Gen Paz 1499, RA-1650 San Martin, Buenos Aires, Argentina
关键词
film-forming amines; octadecylamine; reverse-phase chromatography; sample stabilization; validation; ALIPHATIC-AMINES; WASTE-WATER; DERIVATIZATION;
D O I
10.1002/sscp.202400099
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Octadecylamine (ODA) is the most widely used film-forming amine in the nuclear industry. Its function is to minimize corrosion. In this work, we developed and validated a liquid chromatography-mass spectrometry method that allows the quantification of ODA in the presence of other amines in the secondary system of nuclear power plants operating under all-volatile treatment chemistry. Sample stabilities greater than 95% were achieved after 1 week of being taken in acetonitrile 1:1. The method showed a high selectivity allowing the measurement of ODA in the presence of other amines. The calibration curve was linear in the range of 0.0025-0.1025 mg/L. The limit of detection and limit of quantification (LOQ) were 1.8 and 2.2 mu g/L, respectively for an injection volume of 3 mu L. Lower LOQs can be achieved by increasing the injection volume, making the method applicable even in the first hours and days of treatment. The bias of the method was less than 10% and the relative standard deviation of reproducibility was less than 15%. The sample stabilization was robust and the uncertainty associated with the method was acceptable. The method was applied to a real sample taken after a few years of treatment and a concentration of 0.15 mg/L was measured.
引用
收藏
页数:11
相关论文
共 33 条
[1]  
AOAC International, 2012, AOAC GUIDELINES SING
[2]  
Arias C., 2016, EPRI 5 STEAM GEN SEC
[3]   Impedance analysis of film-forming amines for the corrosion protection of a carbon steel [J].
Baux, Jordan ;
Causse, Nicolas ;
Esvan, Jerome ;
Delaunay, Sophie ;
Tireau, Jonathan ;
Roy, Marion ;
You, Dominique ;
Pebere, Nadine .
ELECTROCHIMICA ACTA, 2018, 283 :699-707
[4]   Sensitive, accurate and rapid detection of trace aliphatic amines in environmental samples with ultrasonic-assisted derivatization microextraction using a new fluorescent reagent for high performance liquid chromatography [J].
Chen, Guang ;
Liu, Jianjun ;
Liu, Mengge ;
Li, Guoliang ;
Sun, Zhiwei ;
Zhang, Shijuan ;
Song, Cuihua ;
Wang, Hua ;
Suo, Yourui ;
You, Jinmao .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1352 :8-19
[5]  
Dooley RB, 2019, PPCHEM, V21, P302
[6]   Photometric determination of octadecylamine with Methyl Orange [J].
Evtushenko, YM ;
Ivanov, VM ;
Zaitsev, BE .
JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 57 (01) :8-11
[7]   Determination of aliphatic amines in mineral flotation liquors and reagents by high-performance liquid chromatography after derivatization with 4-chloro-7-nitrobenzofurazan [J].
Hao, F ;
Lwin, T ;
Bruckard, WJ ;
Woodcock, JT .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1055 (1-2) :77-85
[8]  
Hofman F., 2020, SELFASSEMBLING MONOL
[9]  
Hoock B., 2015, POWERPLANT CHEM, V17, P283
[10]   Tutorial review on validation of liquid chromatography-mass spectrometry methods: Part I [J].
Kruve, Anneli ;
Rebane, Riin ;
Kipper, Karin ;
Oldekop, Maarja-Liisa ;
Evard, Hanno ;
Herodes, Koit ;
Ravio, Pekka ;
Leito, Ivo .
ANALYTICA CHIMICA ACTA, 2015, 870 :29-44