The Precision and Safety of Ultrasound-Guided versus Palpation-Guided Needle Placement on the Plantar Fascia and Flexor Digitorum Brevis Interface: An Anatomical Study

被引:1
|
作者
Malo-Urries, Miguel [1 ]
Borrella-Andres, Sergio [1 ]
Lopez-de-Celis, Carlos [2 ,3 ,4 ]
Fernandez-de-las-Penas, Cesar [5 ]
Perez-Bellmunt, Albert [2 ,3 ]
Arias-Buria, Jose L. [5 ]
Albarova-Corral, Isabel [1 ]
Rodriguez-Sanz, Jacobo [2 ,3 ]
机构
[1] Univ Zaragoza, Hlth Sci Fac, Dept Physiatry & Nursing, Zaragoza 50009, Spain
[2] Univ Int Catalunya, Fac Med & Hlth Sci, Sant Cugat Del Valles 08195, Spain
[3] ACTIUM Funct Anat Grp, Sant Cugat Del Valles 08195, Spain
[4] Univ Recerca Atencio, Fundacio Inst, Primaria Salut Jordi Gol i Gurina IDIAPJGol, Barcelona 08028, Spain
[5] Univ Rey Juan Carlos, Dept Phys Therapy Occupat Therapy Rehabil & Phys M, Alcorcon 28922, Spain
关键词
plantar fascia; ultrasound; needling; interphase; accuracy; safety; cadaver; REGIONAL ANESTHESIA; PERCUTANEOUS ELECTROLYSIS; PAIN;
D O I
10.3390/healthcare12101000
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Evidence suggests the plantar fascia and its interphase with the flexor digitorum brevis muscle can play a relevant role in plantar heel pain. Needling interventions could offer an appropriate treatment strategy to addressing this interface. Objective: We compared the accuracy and safety of ultrasound-guided versus palpation-guided procedures for the proper targeting of the interface between the plantar fascia and the flexor digitorum brevis with a solid needle. Methods: A crossover cadaveric study was conducted. Five experienced therapists performed a series of 20 needle insertions each (n = 100 in total, 10 landmark-guided and 10 ultrasound-guided) on 10 anatomical samples. The therapists were instructed to accurately place the needle on the interface between the plantar fascia and the flexor digitorum brevis muscle. The distance of the tip of the needle to the identified target (accuracy), the surrounding sensitive structures targeted (safety), the time needed for the procedure, the number of needle passes, and the needle length outside the skin were assessed. Results: The ultrasound-guided technique was associated with a significantly higher accuracy (p < 0.001) but without differences in safety (p = 0.249) as compared to the palpation-guided procedure. Conclusion: Our results suggest that ultrasound-guided insertion exhibits greater accuracy but not greater safety than palpation-guided insertion when targeting the interface between the plantar fascia and the flexor digitorum brevis.
引用
收藏
页数:10
相关论文
共 44 条
  • [21] Ultrasound-guided Jamshidi needle puncture to reduce radiation exposure during percutaneous pedicle screw placement: study protocol for a randomised controlled trial
    Wu, Tong
    Chen, Yi-feng
    Huang, Ying
    Meng, Fan-he
    Lu, Jing-han
    Liu, Da
    BMJ OPEN, 2023, 13 (03):
  • [22] A Comparative Study of Safety and Efficacy of Ultrasound-Guided Infra-Clavicular Axillary Vein Cannulation versus Ultrasound-Guided Internal Jugular Vein Cannulation in Adult Cardiac Surgical Patients
    Shinde, Prajakta D.
    Jasapara, Amish
    Bansode, Kishan
    Bunage, Rohit
    Mulay, Anvay
    Shetty, Vijay L.
    ANNALS OF CARDIAC ANAESTHESIA, 2019, 22 (02) : 177 - 186
  • [23] Palpation versus ultrasound-guided corticosteroid injections and short-term effect in the distal radioulnar joint disorder: a randomized, prospective single-blinded study
    Nam, Sang Hyun
    Kim, Jongwoo
    Lee, Ji Hae
    Ahn, Jaeki
    Kim, Young Joo
    Park, Yongbum
    CLINICAL RHEUMATOLOGY, 2014, 33 (12) : 1807 - 1814
  • [24] Comparing Safety in Surface Landmarks Versus Ultrasound-Guided Peripheral Nerve Blocks An Observational Study of a Practice in Transition
    Laur, John J.
    Weinberg, Guy L.
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2012, 37 (06) : 569 - 570
  • [25] A comparative study of ultrasound-guided caudal block versus anatomical landmark-based caudal block in pediatric surgical cases
    Nanjundaswamy, Nethra H.
    Nagappa, Saraswathi
    Shridhara, Raghavendra Biligiri
    Kalappa, Sandya
    INDIAN ANAESTHETISTS FORUM, 2020, 21 (01): : 10 - 15
  • [26] Safety profile and outcome after ultrasound-guided suprainguinal fascia iliaca catheters for hip fracture: a single-centre propensity-matched historical cohort study
    James, Michael
    Bentley, Richard A.
    Womack, Jonathan
    Goodman, Ben A.
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2022, 69 (09): : 1139 - 1150
  • [27] Ultrasound-Guided Autologous Platelet-Rich Plasma Injections Versus Focal Ultrasound-Guided Extracorporeal Shockwave Therapy for Plantar Fasciitis in Athletes and Nonathletes: A Retrospective Comparative Study With Minimum 2-Year Follow-Up
    Alessio-Mazzola, Mattia
    Stambazzi, Chiara
    Ursino, Chiara
    Tagliafico, Alberto
    Trentini, Roberto
    Formica, Matteo
    JOURNAL OF FOOT & ANKLE SURGERY, 2023, 62 (03): : 417 - 421
  • [28] Safety of endoscopic ultrasound-guided fine-needle aspiration for pancreatic solid mass in the elderly: A single-center retrospective study
    Takahashi, Koji
    Ohyama, Hiroshi
    Takiguchi, Yuichi
    Sekine, Yu
    Toyama, Shodai
    Yamada, Nana
    Sugihara, Chihei
    Kan, Motoyasu
    Ouchi, Mayu
    Nagashima, Hiroki
    Iino, Yotaro
    Kusakabe, Yuko
    Okitsu, Kohichiroh
    Ohno, Izumi
    Kato, Naoya
    GERIATRICS & GERONTOLOGY INTERNATIONAL, 2023, 23 (11) : 836 - 841
  • [29] Palpation versus ultrasound-guided corticosteroid injections and short-term effect in the distal radioulnar joint disorder: a randomized, prospective single-blinded study
    Sang Hyun Nam
    Jongwoo Kim
    Ji Hae Lee
    Jaeki Ahn
    Young Joo Kim
    Yongbum Park
    Clinical Rheumatology, 2014, 33 : 1807 - 1814
  • [30] Comparison between marked versus unmarked introducer needle in real-time ultrasound-guided central vein cannulation: A prospective randomized study
    Ghatak, Tanmoy
    Singh, Ratender Kumar
    Baronia, Arvind Kumar
    ANNALS OF CARDIAC ANAESTHESIA, 2016, 19 (04) : 621 - 625