Rationalizing polyp matching criteria in colon capsule endoscopy: an international expert consensus through RAND (modified DELPHI) process

被引:5
作者
Lei, Ian Io [1 ,2 ]
Koulaouzidis, Anastasios [3 ,4 ,5 ,6 ]
Baatrup, Gunnar [3 ,4 ]
Samaan, Mark [7 ]
Parisi, Ioanna [8 ]
McAlindon, Mark [9 ,10 ]
Toth, Ervin [11 ]
Shaukat, Aasma [12 ]
Valentiner, Ursula [13 ,14 ]
Dabos, Konstantinos John [15 ]
Fernandez, Ignacio [16 ]
Robertson, Alexander [2 ]
Schelde-Olesen, Benedicte [3 ]
Parsons, Nicholas [17 ]
Arasaradnam, Ramesh P.
机构
[1] Univ Hosp Coventry & Warwickshire, Inst Precis Diagnost & Translat Med, Clifford Bridge Rd, Coventry CV2 2DX, W Midlands, England
[2] Univ Hosp Leicester NHS Trust, Dept Digest Dis, Leicester, Leics, England
[3] Odense Univ Hosp, Surg Res Unit, Svendborg, Denmark
[4] Univ Southern Denmark, Dept Clin Res, Odense, Denmark
[5] Pomeranian Med Univ, Dept Social Med & Publ Hlth, Szczecin, Poland
[6] OUH Svendborg Sygehus, Dept Med, Svendborg, Denmark
[7] Guys & St Thomas NHS Fdn Trust, Inflammatory Bowel Dis Unit, London, England
[8] Univ Coll Hosp, Dept Gastroenterol, London, England
[9] Sheffield Teaching Hosp, Royal Hallamshire Hosp, Acad Unit Gastroenterol, Sheffield, England
[10] Univ Sheffield, Dept Infect Immun & Cardiovasc Dis, Sheffield, England
[11] Lund Univ, Dept Gastroenterol, Skane Univ Hosp, Malmo, Sweden
[12] NYU Grossman Sch Med, Dept Med, Div Gastroenterol, New York, NY USA
[13] Corp Hlth Int, Inverness, Scotland
[14] Univ Med Ctr Hamburg Eppendorf, Inst Anat & Expt Morphol, Hamburg, Germany
[15] St Johns Hosp, Gastroenterol Department, Livingston, West Lothian, Scotland
[16] CHN, Dept Pathol, Pamplona, Spain
[17] Univ Warwick, Warwick Clin Trials Unit, Coventry, England
关键词
capsule endoscopy; colon capsule endoscopy; colorectal polyp; polyp; colorectal cancer; CCE; polyp matching; COLONOSCOPY;
D O I
10.1177/17562848241242681
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Colon capsule endoscopy (CCE) has gained momentum as an alternative modality for the investigation of the lower gastrointestinal tract. Of the few challenges that remain, the comparison and - eventually - matching of polyps at different timestamps leads to the potential for double reporting and can contribute to false-positive findings and inaccuracies. With the impending artificial intelligence integration, the risk of double reporting the same polyp due to the lack of information on spatial orientation underscores the necessity for establishing criteria for polyp matching.Objectives: This RAND/University of California, Los Angeles (modified Delphi) process aims to identify the key factors or components used to match polyps within a CCE video. This involves exploring the attributes of each factor to create comprehensive polyp-matching criteria based on international expert consensus.Design: A systematic qualitative study using surveys.Methods: A panel of 11 international CCE experts convened to assess a survey comprised of 60 statements. Participants anonymously rated statement appropriateness on a 1-9 scale (1-3: inappropriate, 4-6: uncertain and 7-9: appropriate). Following a virtual group discussion of the Round 1 results, a Round 2 survey was developed and completed before the final analysis.Results: The factors that were agreed to be essential for polyp matching include (1) timestamp, (2) polyp localization, (3) polyp vascular pattern, (4) polyp size, (5) time interval of the polyp appearance between the green and yellow camera, (6) surrounding tissue, (7) polyp morphology and (8) polyp surface and contour. When five or more factors are satisfied, it was agreed that the comparing polyps are likely the same polyp.Conclusion: This study has established the first complete criteria for polyp matching in CCE. While it might not provide a definitive solution for matching difficult, small and common polyps, these criteria serve as a framework to guide and facilitate the process of polyp-matching. Creating criteria and standards for matching polyps (abnormal growth in the bowels) on colon capsule video analysis: an international expert agreement using the RAND (modified Delphi process) processBackground: Doctors often use colon capsule endoscopy (CCE), a high-tech capsule with two cameras, to record and check for diseases in the small and large bowels as the capsule travels through the intestines. One of the most common conditions in the large bowel is polyps, which are abnormal growths in the lining of the bowel. Comparing and matching polyps in the same video from the capsule can be tricky as they look very similar, leading to the possibility of incorrectly reporting the same polyp twice or more. This can lead to wrong results and inaccuracies. The literature did not have any criteria or standards for matching polyps in CCE before.Aim: Using the RAND/UCLA (modified Delphi) process, this study aims to identify the key factors or components used to match polyps within a CCE video. The goal is to explore each factor and create complete criteria for polyp matching based on the agreement from international experts.Method: A group of 11 international CCE experts came together to evaluate a survey with 60 statements. They anonymously rated each statement on a scale from 1 to 9 (1-3: inappropriate, 4-6: uncertain, and 7-9: appropriate). After discussing the Round 1 results virtually, a Round 2 survey with the same but revised questions was created and completed before the final analysis of their agreement.Results: The main factors for matching polyps are 1) the timing when the polyp was seen, 2) where it is in the bowel, 3) its blood vessel pattern, 4) size, 5) the timing of its appearance between cameras, 6) surrounding tissue features, 7) its shape, and 8) surface features. If five or more of these factors match, the compared polyps are likely the same.Conclusion: This study establishes the first complete criteria for matching polyps in CCE. While it may not provide a definitive solution for matching challenging and small polyps, these criteria serve as a guide to help and make the process of polyp matching easier.
引用
收藏
页数:12
相关论文
共 31 条
[1]   Live Image Processing Does Not Increase Adenoma Detection Rate During Colonoscopy: A Randomized Comparison Between FICE and Conventional Imaging (Berlin Colonoscopy Project 5, BECOP-5) [J].
Aminalai, Alireza ;
Roesch, Thomas ;
Aschenbeck, Jens ;
Mayr, Michael ;
Drossel, Rolf ;
Schroeder, Andreas ;
Scheel, Matthias ;
Treytnar, Doris ;
Gauger, Ulrich ;
Stange, Gabriela ;
Simon, Frank ;
Adler, Andreas .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2010, 105 (11) :2383-2388
[2]   Localization strategies for robotic endoscopic capsules: a review [J].
Bianchi, Federico ;
Masaracchia, Antonino ;
Barjuei, Erfan Shojaei ;
Menciassi, Arianna ;
Arezzo, Alberto ;
Koulaouzidis, Anastasios ;
Stoyanov, Danail ;
Dario, Paolo ;
Ciuti, Gastone .
EXPERT REVIEW OF MEDICAL DEVICES, 2019, 16 (05) :381-403
[3]   Capsule endoscopy vs. colonoscopy vs. histopathology in colorectal cancer screening: matched analyses of polyp size, morphology, and location estimates [J].
Blanes-Vidal, Victoria ;
Nadimi, Esmaeil S. ;
Buijs, Maria Magdalena ;
Baatrup, Gunnar .
INTERNATIONAL JOURNAL OF COLORECTAL DISEASE, 2018, 33 (09) :1309-1312
[4]   Intra and inter-observer agreement on polyp detection in colon capsule endoscopy evaluations [J].
Buijs, Maria Magdalena ;
Kroijer, Rasmus ;
Kobaek-Larsen, Morten ;
Spada, Cristiano ;
Fernandez-Urien, Ignacio ;
Steele, Robert J. C. ;
Baatrup, Gunnar .
UNITED EUROPEAN GASTROENTEROLOGY JOURNAL, 2018, 6 (10) :1563-1568
[5]   Multicentre, prospective, randomised study comparing the diagnostic yield of colon capsule endoscopy versus CT colonography in a screening population (the TOPAZ study) [J].
Cash, Brooks D. ;
Fleisher, Mark R. ;
Fern, Steven ;
Rajan, Elizabeth ;
Haithcock, Robyn ;
Kastenberg, David M. ;
Pound, David ;
Papageorgiou, Neofytos P. ;
Fernandez-Urien, Ignacio ;
Schmelkin, Ira J. ;
Rex, Douglas K. .
GUT, 2021, 70 (11) :2115-2122
[6]  
Fitch K., 2001, The RAND/UCLA Appropriateness Method User's Manual
[7]   ACCORD (ACcurate COnsensus Reporting Document): A reporting guideline for consensus methods in biomedicine developed via a modified Delphi [J].
Gattrell, William T. ;
Logullo, Patricia ;
van Zuuren, Esther J. ;
Price, Amy ;
Hughes, Ellen L. ;
Blazey, Paul ;
Winchester, Christopher C. ;
Tovey, David ;
Goldman, Keith ;
Hungin, Amrit Pali ;
Harrison, Niall .
PLOS MEDICINE, 2024, 21 (01)
[8]   Miss rate for colorectal neoplastic polyps:: a prospective multicenter study of back-to-back video colonoscopies [J].
Heresbach, D. ;
Barrioz, T. ;
Lapalus, M. G. ;
Coumaros, D. ;
Bauret, P. ;
Potier, P. ;
Sautereau, D. ;
Boustiere, C. ;
Grimaud, J. C. ;
Barthelemy, C. ;
See, J. ;
Serraj, I. ;
Halluin, P. N. D. ;
Branger, B. ;
Ponchan, T. .
ENDOSCOPY, 2008, 40 (04) :284-290
[9]  
James Turvill MM., 2023, Gut J, V72
[10]  
Kiriyama Shinsuke, 2012, Diagn Ther Endosc, V2012, P596303, DOI 10.1155/2012/596303