Digitally fabricated provisional implant restorations prior to implant placement

被引:0
|
作者
Gallucci, German O.
机构
来源
IMPLANTOLOGIE | 2024年 / 32卷 / 01期
关键词
digital workflow; guided implant surgery; CAD/CAM; temporary restoration; healing abutment; single implant; implant planning; DVT; planning software; BEAM COMPUTED-TOMOGRAPHY; TECHNOLOGY APPLICATIONS; IMMEDIATE RESTORATION; HEALING ABUTMENT; DENTAL IMPLANTS; SOFT-TISSUE; SURGERY; DENTISTRY; ACCURACY; SURFACE;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
To review the factors that affect the ability to deliver a CAD/CAM implant -supported provisional restoration designed from a virtually planned implant position prior to surgical placement with static computer -assisted implant surgery (sCAIS). Data were collected on patients treated with single -tooth implant treatment in which CBCT was combined with intraoral scans and imported into a virtual implant planning software. A synchronization tool established the connection between the planning software and the CAD software, where a digital diagnostic tooth arrangement was performed to create the ideal tooth dimensions and mucosal architecture. The virtual implant planning was finalized, and the implant position was transferred to the CAD software, where a restoration was designed and fabricated. The sCAIS was performed, and the prefabricated custom restorations were delivered on the day of the surgery or following healing if delayed loading or submerged healing was required. Descriptive statistics and statistical comparison with two -proportion z test were performed. A total of 23 patients with 28 single -implant sites met the inclusion criteria and were included in the study. Nineteen customized healing abutments and 10 provisional crowns were designed and fabricated for a total of 29 restorations. Of the restorations, 23 were successfully delivered on the day of the surgical intervention. No statistical significance was found among the different variables compared. Custom prefabricated CAD/CAM restorations based on a virtually planned implant position can be successfully designed, fabricated, and delivered when used in combination with sCAIS.
引用
收藏
页码:65 / 79
页数:15
相关论文
共 50 条
  • [11] Methods Used to Assess the 3D Accuracy of Dental Implant Positions in Computer-Guided Implant Placement: A Review
    Pyo, Se-Wook
    Lim, Young-Jun
    Koo, Ki-Tae
    Lee, Jungwon
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (01)
  • [12] The color stability and wear resistance of provisional implant restorations: A prospective clinical study
    Alevizakos, Vasilios
    Mitov, Gergo
    Teichert, Franziska
    von See, Constantin
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2020, 6 (05): : 568 - 575
  • [13] Digitally prefabricated versus conventionally fabricated implant-supported full-arch provisional prosthesis: a retrospective cohort study
    Chen, Chaoqun
    Lai, Haiyan
    Zhu, Huiyong
    Gu, Xinhua
    BMC ORAL HEALTH, 2022, 22 (01)
  • [14] Accuracy of implant placement with a computer-aided fabricated surgical template with guided parallel pins: A pilot study
    Chang, Rai-Jei
    Chen, Hui-Ling
    Huang, Liang-Gie
    Wong, Yong-Kie
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2018, 81 (11) : 970 - 976
  • [15] Comparison of Implant and Provisional Placement Protocols in Sinus-Augmented Bone: A Preliminary Report
    Lang, Lisa A.
    Edgin, Wendell A.
    Garcia, Lily T.
    Olvera, Norma
    Verrett, Ronald
    Bohnenkamp, David
    Haney, Stephen J.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (03) : 648 - 656
  • [16] Digitally guided root removal and simultaneous implant placement: A case study
    Gala, Roksolana
    Al Sammarraie, Mohammed
    Padilla, Rocio Sanchez
    Zhou, Zheng
    Neely, Anthony L.
    Kinaia, Bassam M.
    CLINICAL ADVANCES IN PERIODONTICS, 2024,
  • [17] Effect of khat extract on color stability of digitally and manually fabricated provisional restorations: an in vitro comparative study
    Al-Akhali, Abd Al-Rhaman M.
    Al-Hamzi, Mohsen
    Al-Shami, Ibrahim Z.
    Al-Kholani, Abdulwahab I.
    Madfa, Ahmed A.
    BMC ORAL HEALTH, 2023, 23 (01)
  • [18] Antibiotic prophylaxis for implant placement: a systematic review of effects on reduction of implant failure
    Kim, Andy
    Abdelhay, Nancy
    Levin, Liran
    Walters, John D.
    Gibson, Monica P.
    BRITISH DENTAL JOURNAL, 2020, 228 (12) : 943 - 951
  • [19] Computer-assisted implant placement and full-arch immediate loading with digitally prefabricated provisional prostheses without cast: a prospective pilot cohort study
    Nikolay Makarov
    Giorgio Pompa
    Piero Papi
    International Journal of Implant Dentistry, 7
  • [20] Accuracy of robotic computer-assisted implant surgery for immediate implant placement: A retrospective case series study
    Li, Ping
    Zhao, Chunhui
    Chen, Jiahao
    Xu, Shulan
    Yang, Shuo
    Li, An
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (06) : 1279 - 1288