UNCERTAINTY QUANTIFICATION ON THE COOLING PERFORMANCE OF A TRANSONIC TURBINE VANE WITH UPSTREAM ENDWALL MISALIGNMENT

被引:0
|
作者
Hao, Mingyang [1 ]
Li, Yuanyuan [2 ]
Li, Zhigang [1 ]
Li, Jun [1 ]
机构
[1] Xi An Jiao Tong Univ, Inst Turbomachinery, Xian 710049, Peoples R China
[2] Xian Thermal Power Res Inst, Xian, Peoples R China
基金
中国国家自然科学基金;
关键词
Film Cooling; Upstream misalignment; UQ; POLYNOMIAL CHAOS;
D O I
暂无
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
With increasing aerodynamic and thermal loads, film cooling has been a popular technology integrated into the design of the modern gas turbine vane endwall, especially for the first-stage vane endwall. A staggering amount of research has been completed to quantify the effect of operating conditions and cooling hole geometrical properties. However, most of these investigations did not address the influence of the manufacturing tolerances, assembly errors and operation degradations on the endwall misalignment. In this paper, therefore, uncertainty quantification (UQ) analysis was performed to quantify the impacts of upstream endwall misalignment uncertainties on the film cooling performance of endwalls as well as the phantom cooling performance of the vane pressure side surface. The upstream endwall misalignment represents the step geometry between the combustor exit and the first-stage vane endwall. Based on the non-intrusive polynomial chaos expansion (NIPC) and the Uniform probability distribution assumption, the deviation (step height) uncertainties of the upstream endwall misalignment were quantified. To predict the endwall secondary flow and film cooling effectiveness in the transonic linear vane passage, the commercial CFD solver ANSYS FLUENT is used to numerically solve the three dimensional steady-state Reynolds-Averaged Navier-Stokes (RANS) equations. The robustness analysis of endwall film cooling performance and phantom cooling to the upstream endwall misalignment was conducted for three design upstream step heights (Delta H): a baseline configuration (Delta H = 0 mm), two misaligned configurations with forward step (Delta H = -5 mm) and backward step (Delta H = 5 mm) respectively. Results show that the actual cooling performance has a high probability of deviating from the nominal value for the baseline configuration. The critical regions that are most sensitive to the upstream step misalignment are also identified by variances. The UQ results also show that the design geometry with a forward step has a more robust film cooling performance on endwall and phantom cooling performance on the vane pressure side surface which means a smaller variance and a better expectation than the no step configuration. In contrast, the design geometry with a backward step induces the reductions of the expectation of the film cooling effectiveness and coolant coverage and the amplification of performance fluctuations. This work provides a certain guiding direction for the optimization design for the upstream step geometry.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] EFFECT OF COMBUSTOR-TURBINE PLATFORM MISALIGNMENT ON THE AERODYNAMICS AND HEAT TRANSFER OF AN AXISYMMETRIC CONVERGING VANE ENDWALL AT TRANSONIC CONDITIONS
    Mayo, David E., Jr.
    Arisi, Allan
    Ng, Wing F.
    Moon, Hee-Koo
    Li, Zhigang
    Li, Jun
    Zhang, Luzeng
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2017, VOL 5A, 2017,
  • [22] Effects of Upstream Endwall Film Cooling on a Vane Cascade Flowfield
    Mahmood, Gazi I.
    Arnachellan, Keenesh
    JOURNAL OF PROPULSION AND POWER, 2018, 34 (02) : 460 - 468
  • [23] TURBINE VANE ENDWALL FILM COOLING CONSIDERING FLOW NONUNIFORMITIES AND COOLANT INJECTION FROM UPSTREAM COMBUSTORS
    Yang, Xing
    Zhao, Qiang
    Feng, Zhenping
    HEAT TRANSFER RESEARCH, 2021, 52 (13) : 11 - 31
  • [24] Film cooling effectiveness from upstream purge slots of a turbine vane endwall: Experiment, modeling, and correlation
    Yang, Xing
    Zhao, Qiang
    Wu, Hang
    Feng, Zhenping
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 219
  • [25] EXPERIMENTAL STUDY OF THE ENDWALL HEAT TRANSFER OF A TRANSONIC NOZZLE GUIDE VANE WITH UPSTREAM JET PURGE COOLING: PART 2-EFFECT OF COMBUSTOR-NGV MISALIGNMENT
    Sibold, Ridge A.
    Mao, Shuo
    Ng, Wing F.
    Xu, Hongzhou
    Fox, Michael
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, VOL 7B, PT I, 2020,
  • [26] Effects of vortex generators on endwall film cooling in a turbine vane
    Zhao, Zhiyuan
    Wen, Fengbo
    Luo, Yuxi
    Wang, Ying
    Zhang, Xinghong
    Wang, Songtao
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 153
  • [27] Influence of hole shape on the performance of a turbine vane endwall film-cooling scheme
    Colban, W.
    Thole, K.
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2007, 28 (03) : 341 - 356
  • [28] AERODYNAMIC PERFORMANCE OF A TRANSONIC TURBINE BLADE PASSAGE IN PRESENCE OF UPSTREAM SLOT AND MATEFACE GAP WITH ENDWALL
    Jain, Sakshi
    Roy, Arnab
    Ng, Wing
    Ekkad, Srinath
    Lohaus, Andrew S.
    Taremi, Farzad
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2014, VOL 2C, 2014,
  • [29] FILM COOLING PERFORMANCE OF TRIPOD HOLES ON THE ENDWALL UPSTREAM OF A FIRST STAGE NOZZLE GUIDE VANE
    Ravi, Bharath Viswanath
    Deshpande, Samruddhi
    Ramesh, Sridharan
    Dhilipkumar, Prethive Dhilip
    Ekkad, Srinath
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2015, VOL 8B, 2016,
  • [30] Effects of Effusion Cooling and Slot Jet Flow on Aerothermal Performance of Turbine Vane Endwall
    Sun T.-Y.
    Li Z.-G.
    Li J.
    Tuijin Jishu/Journal of Propulsion Technology, 2022, 43 (08):